An Improved FastICA Method for Fetal ECG Extraction

被引:38
作者
Yuan, Li [1 ]
Zhou, Zhuhuang [1 ]
Yuan, Yanchao [1 ]
Wu, Shuicai [1 ]
机构
[1] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金; 中国博士后科学基金;
关键词
QRS COMPLEX DETECTION; ABDOMINAL ECG; SEPARATION; OPTIMIZATION;
D O I
10.1155/2018/7061456
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective. The fast fixed-point algorithm for independent component analysis (FastICA) has been widely used in fetal electrocardiogram (ECG) extraction. However, the FastICA algorithm is sensitive to the initial weight vector, which affects the convergence of the algorithm. In order to solve this problem, an improved FastICA method was proposed to extract fetal ECG. Methods. First, the maternal abdominal mixed signal was centralized and whitened, and the overrelaxation factor was incorporated into Newton's iterative algorithm to process the initial weight vector randomly generated. The improved FastICA algorithm was used to separate the source components, selected the best maternal ECG from the separated source components, and detected the R-wave location of the maternal ECG. Finally, the maternal ECG component in each channel was removed by the singular value decomposition (SVD) method to obtain a clean fetal ECG signal. Results. An annotated clinical fetal ECG database was used to evaluate the improved algorithm and the conventional FastICA algorithm. The average number of iterations of the algorithm was reduced from 35 before the improvement to 13. Correspondingly, the average running time was reduced from 1.25 s to 1.04 s when using the improved algorithm. The signal-to-noise ratio (SNR) based on eigenvalues of the improved algorithm was 1.55, as compared to 0.99 of the conventional FastICA algorithm. The SNR based on cross-correlation coefficients of the conventional algorithm was also improved from 0.59 to 2.02. The sensitivity, positive predictive accuracy, and harmonic mean (F-1) of the improved method were 99.37%, 99.00%, and 99.19%, respectively, while these metrics of the conventional FastICA method were 99.03%, 98.53%, and 98.78%, respectively. Conclusions. The proposed improved FastICA algorithm based on the overrelaxation factor, while maintaining the rate of convergence, relaxes the requirement of initial weight vector, avoids the unbalanced convergence, reduces the number of iterations, and improves the convergence performance.
引用
收藏
页数:7
相关论文
共 20 条
[1]  
AAMI, 2008, EC571998R2008 AAMI A
[2]   A Comparison of Single Channel Fetal ECG Extraction Methods [J].
Behar, Joachim ;
Johnson, Alistair ;
Clifford, Gari D. ;
Oster, Julien .
ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (06) :1340-1353
[3]   A Combined Independent Source Separation and Quality Index Optimization Method for Fetal ECG Extraction from Abdominal Maternal Leads [J].
Billeci, Lucia ;
Varanini, Maurizio .
SENSORS, 2017, 17 (05)
[4]  
Binfeng Xu, 2012, 2012 9th International Conference on Fuzzy Systems and Knowledge Discovery, P1787, DOI 10.1109/FSKD.2012.6233878
[5]   Separation and Analysis of Fetal-ECG Signals From Compressed Sensed Abdominal ECG Recordings [J].
Da Poian, Giulia ;
Bernardini, Riccardo ;
Rinaldo, Roberto .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (06) :1269-1279
[6]   An advanced algorithm for fetal heart rate estimation from non-invasive low electrode density recordings [J].
Dessi, Alessia ;
Pani, Danilo ;
Raffo, Luigi .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (08) :1621-1636
[7]   A new method for the extraction of fetal ECG from the dependent abdominal signals using blind source separation and adaptive noise cancellation techniques [J].
Ghazdali, Abdelghani ;
Hakim, Abdelilah ;
Laghrib, Amine ;
Mamouni, Nezha ;
Raghay, Said .
THEORETICAL BIOLOGY AND MEDICAL MODELLING, 2015, 12
[8]   Fast and robust fixed-point algorithms for independent component analysis [J].
Hyvärinen, A .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1999, 10 (03) :626-634
[9]   A Fetal Electrocardiogram Signal Extraction Algorithm Based on Fast One-Unit Independent Component Analysis with Reference [J].
Jia, Yanfei ;
Yang, Xiaodong .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
[10]   Efficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection [J].
Li, Ruilin ;
Frasch, Martin G. ;
Wu, Hau-Tieng .
FRONTIERS IN PHYSIOLOGY, 2017, 8