Operation of a vertical thermosiphon reboiler experimental facility at reduced pressures

被引:10
作者
Benson, HRS
Schnabel, T
Webb, DR
Heggs, PJ [1 ]
机构
[1] UMIST, Dept Chem Engn, Manchester, Lancs, England
[2] Univ Stuttgart, ITT, Stuttgart, Germany
基金
英国工程与自然科学研究理事会;
关键词
vertical thermosiphon; reboiler; low pressure; instability;
D O I
10.1205/026387604323050155
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experimental data were obtained for the evaporation of water in a vertical thermosiphon reboiler having 50 tubes of 3 m length and 25.4 mm outer diameter. The effect of step changes in heat load was noted for operation over a pressure range from 0.2 to 1.0 bar. The reboiler behaviour exhibited three 'operational modes', and a definite transitional point that is independent of process pressure was observed between operational modes one and two. The influence of reduced pressures on the vertical thermosiphon reboiler sub-cooled heating length was significant. Overall heat transfer coefficients at 0.2 bar were about 60% of those at 1.0 bar and circulation rates were approximately halved. Two important considerations for the reboiler operation analysis were (a) the possible non-uniform behaviour of the reboiler tubes and (b) the change of phase and processes occurring on the reboiler shell as well as the tube side.