Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT

被引:42
作者
Rixe, J. [1 ]
Conradi, G. [1 ]
Rolf, A. [1 ]
Schmermund, A. [2 ]
Magedanz, A. [2 ]
Erkapic, D. [1 ]
Deetjen, A. [3 ]
Hamm, C. W. [1 ]
Dill, T. [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Cardioangiol Zentrum Bethanien, Frankfurt, Germany
[3] Katharinen Hosp, Dept Cardiol, D-70174 Stuttgart, Germany
关键词
TUBE CURRENT MODULATION; MULTIDETECTOR ROW CT; IMAGE QUALITY; PERFORMANCE EVALUATION; PHANTOM MEASUREMENTS; MULTISLICE CT; CARDIAC CT; PATIENT; REDUCTION; HEART;
D O I
10.1136/hrt.2008.161018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dual-source CT (DSCT) promises a significant reduction of radiation dose exposure for coronary CT angiography (CTA). Large studies on radiation dose estimates are rare. Objective: To compare radiation dose estimates of DSCT with 16- and 64-slice multidetector CT (MDCT) for non-invasive coronary angiography. Patients and design: Retrospective data analysis was performed on 292 patients: 56 patients were examined with 16- slice MDCT, 38 patients with 64-slice MDCT and 202 patients using DSCT. The effective dose (ED) estimates were calculated for all patients from the dose length product and the conversion factor k (0.017 mSv/mGy/cm), as recommended by current guidelines. Results: The mean (SD) ED for patients examined by 16-slice MDCT was 9.8 (1.8) mSv, for 64-slice MDCT 8.6 (2.8) mSv and for DSCT 11.4 (7.2) mSv. With a protocol of 100 kV tube voltage and 110 ms ECG pulsing window the mean (SD) ED was 3.8 (1.7) mSv for DSCT scanning. When DSCT with a tube voltage of 100 kV was used, a significant inverse correlation between heart rate and radiation dose exposure was found. Conclusions: When standard protocols for coronary CTA with 16-, 64-slice MDCT and DSCT scanners are used, the radiation dose is still high. However, using optimised and individually adjusted protocols low estimated radiation doses can be achieved.
引用
收藏
页码:1337 / 1342
页数:6
相关论文
共 34 条
[11]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[12]   Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[13]   Dose reduction in multislice computed tomography [J].
Hundt, W ;
Rust, F ;
Stäbler, A ;
Wolff, H ;
Suess, C ;
Reiser, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) :140-147
[14]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[15]  
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
[16]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[17]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[18]   Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control [J].
Kalra, Mannudeep K. ;
Naz, Nausheen ;
Rizzo, Stefania M. R. ;
Blake, Michael A. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2005, 34 (05) :171-181
[19]   Chest CT performed with z-axis modulation: Scanning protocol and radiation dose [J].
Kalra, MK ;
Rizzo, S ;
Maher, MM ;
Halpern, EF ;
Toth, TL ;
Shepard, JAO ;
Aquino, SL .
RADIOLOGY, 2005, 237 (01) :303-308
[20]  
LEHERON JC, 1992, PHYS MED BIOL, V37, P2117, DOI 10.1088/0031-9155/37/11/008