Zero sequence behaviour of a double-circuit overhead line

被引:27
作者
Benato, Roberto [1 ]
Sessa, Sebastian Dambone [1 ]
Guglielmi, Fabio [1 ]
Partal, Ertugrul [2 ]
Tleis, Nasser [3 ]
机构
[1] Univ Padua, Dept Ind Engn, I-35131 Padua, Italy
[2] Natl Grid Elect Transmiss, Warwick CV34 6DA, England
[3] Power & Water Planning Div, Dubai, U Arab Emirates
关键词
Sequence impedances; Double-circuit OHL; Multiconductor Cell Analysis; Clarke's equivalent circuit;
D O I
10.1016/j.epsr.2014.07.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positive, negative and zero sequence series impedances (in Omega/km units) are the first step for power flow and short circuit analyses and are also necessary for setting the distance relays. The paper is devoted to the computation of zero sequence series impedance (in Omega/km units) (self and mutual) in double-circuit overhead lines (OHLs) with one or more earth wires. A systematic comparison with matrix approaches demonstrates that IEC 60909-2 formula adds the zero sequence self and the zero sequence mutual impedance between the two circuits. This approximation of having a unique value of zero sequence impedance is misleading and gives great errors when phase-to-ground short circuit occurs along a circuit. It is worth noting that the zero sequence mutual impedance between parallel circuits installed on the same tower may be as high as 50% (or more) of the zero sequence self impedance of a circuit alone. Consequently, zero sequence mutual impedance between the two circuits cannot be neglected or mixed. MCA (Multiconductor Cell Analysis) shows that the simplified IEC approach underestimates heavily (more than 18%, depending upon the spacing between the circuits) the phase-to-ground fault current for a fault occurrence along one circuit of the double circuit. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 15 条
  • [1] [Anonymous], 2001, 609090 IEC
  • [2] [Anonymous], 1926, Bell Syst Tech J, DOI DOI 10.1002/J.1538-7305.1926.TB00122.X
  • [3] [Anonymous], 2008, 609092 IEC
  • [4] [Anonymous], 1991, BRIT EL INT MOD POW
  • [5] Benato R., 2010, PERFORMANCE PLANNING
  • [6] Benato R, 2012, TRANS DISTRIB CONF
  • [7] Determination of Steady-State and Faulty Regimes of Overhead Lines by Means of Multiconductor Cell Analysis (MCA)
    Benato, Roberto
    Sessa, Sebastian Dambone
    Guglielmi, Fabio
    [J]. ENERGIES, 2012, 5 (08) : 2771 - 2793
  • [8] Harmonic behaviour of HVDC cables
    Benato, Roberto
    Forzan, Michele
    Marelli, Marco
    Orini, Ambrogio
    Zaccone, Ernesto
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2012, 89 : 215 - 222
  • [10] Calero F., 2007, P 4 INT C POW SYST P, P11