Free-breathing, three-dimensional coronary artery magnetic resonance angiography: Comparison of sequences

被引:30
作者
Weber, OM
Pujadas, S
Martin, AJ
Higgins, CB
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Hosp Santa Creu & Sant Pau, Barcelona, Spain
[3] Philips Med Syst, Best, Netherlands
关键词
magnetic resonance imaging; magnetic resonance angiography; coronary arteries; steady-state free precession; spiral MRI; radial MRI;
D O I
10.1002/jmri.20141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare six free-breathing, three-dimensional, magnetization-prepared coronary magnetic resonance angiography (MRA) sequences. Materials and Methods: Six bright-blood sequences were evaluated: Cartesian segmented gradient echo (C-SGE), radial SGE (R-SGE), spiral SGE (S-SGE), spiral gradient echo (S-GE), Cartesian steady-state free precession (C-SSFP), and radial SSFP (R-SSFP). The right coronary artery (RCA) was imaged in 10 healthy volunteers using all six sequences in randomized order. Images were evaluated by two observers with respect to signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), visible vessel length, vessel edge sharpness, and vessel diameter. Results: C-SSFP depicted RCA over the longest distance with high vessel sharpness, good SNR, and excellent background suppression. S-GE provided best SNR and CNR in proximal segments, but more vessel blurring and poorer background suppression, resulting in poor visualization of distal segments. R-SSFP images showed good background suppression and best vessel sharpness, but only moderate SNR. C-SGE provided good SNR and reasonable CNR, but lowest vessel sharpness. S-SGE and R-SGE visualized the RCA over the smallest distance, mostly due to vessel blurring and low SNR, respectively. Conclusion: Overall, Cartesian SSFP provided the best image quality with excellent vessel sharpness, visualization of long vessel segments, and good SNR and CNR.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 33 条
[1]   Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography [J].
Börnert, P ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Koken, P ;
Spuentrup, E ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :789-794
[2]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[3]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[4]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[5]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[6]   Three-dimensional navigator coronary MRA with the aid of a blood pool agent in pigs: Improved image quality with inclusion of the contrast agent first-pass [J].
Dirksen, MS ;
Kaandorp, TAM ;
Lamb, HJ ;
Doornbos, J ;
Corot, C ;
de Roos, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (04) :502-506
[7]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[8]  
Gatehouse PD, 1999, MAGNET RESON MED, V41, P1023, DOI 10.1002/(SICI)1522-2594(199905)41:5<1023::AID-MRM22>3.0.CO
[9]  
2-1
[10]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158