Predicting surface strains at the human distal radius during an in vivo loading task - Finite element model validation and application

被引:19
作者
Bhatia, Varun A. [1 ]
Edwards, W. Brent [2 ]
Troy, Karen L. [3 ]
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL USA
[2] Univ Calgary, Human Performance Lab, Fac Kinesiol, Calgary, AB, Canada
[3] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Cadaver testing; Strain gage; Finite element; Bone; Human; Bone adaptation; Physical activity; TRABECULAR BONE; LONG BONES; KINEMATICS; STRENGTH; MASS; ACCURACY; ADULTS; YOUNG;
D O I
10.1016/j.jbiomech.2014.04.050
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density. Our objective was to create and validate methods for subject-specific finite element (FE) model generation that would accurately predict the surface strains experienced by the distal radius during an in vivo loading task, and to apply these methods to a group of 23 women aged 23-35 to examine variations in strain, bone mass and density, and physical activity. Four cadaveric specimens were experimentally tested and specimen-specific FE models were developed to accurately predict periosteal surface strains (root mean square error=16.3%). In the living subjects, when 300 N load was simulated, mean strains were significantly inversely correlated with BMC (r=-0.893), BMD (r=-0.892) and physical activity level (r=-0.470). Although the group of subjects was relatively homogenous, BMD varied by two-fold (range: 0.19-0.40 g/cm(3)) and mean energy-equivalent strain varied by almost six-fold (range: 226.79-1328.41 mu epsilon) with a simulated 300 N load. In summary, we have validated methods for estimating surface strains in the distal radius that occur while leaning onto the palm of the hand. In our subjects, strain varied widely across individuals, and was inversely related to bone parameters that can be measured using clinical CT, and inversely related to physical activity history. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2759 / 2765
页数:7
相关论文
共 37 条
  • [1] Daily impact score in long-term acceleration measurements of exercise
    Ahola, Riikka
    Korpelainen, Raija
    Vainionpaa, Aki
    Jamsa, Timo
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (10) : 1960 - 1964
  • [2] Validation of finite element predictions of cartilage contact pressure in the human hip joint
    Anderson, Andrew E.
    Ellis, Benjamin J.
    Maas, Steve A.
    Peters, Christopher L.
    Weiss, Jeffrey A.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (05):
  • [3] Anderson Donald D, 2005, Iowa Orthop J, V25, P108
  • [4] ARMSTRONG CG, 1984, J BIOMECH ENG-T ASME, V106, P165, DOI 10.1115/1.3138475
  • [5] Optimum frequency of exercise for bone health: Randomised controlled trial of a high-impact unilateral intervention
    Bailey, Christine A.
    Brooke-Wavell, Katherine
    [J]. BONE, 2010, 46 (04) : 1043 - 1049
  • [6] Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
    Biswas, Debdut
    Bible, Jesse E.
    Bohan, Michael
    Simpson, Andrew K.
    Whang, Peter G.
    Grauer, Jonathan N.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) : 1882 - 1889
  • [7] COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE
    CARTER, DR
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) : 954 - 962
  • [8] MECHANICAL AND TEXTURAL PROPERTIES OF PELVIC TRABECULAR BONE
    DALSTRA, M
    HUISKES, R
    ODGAARD, A
    VANERNING, L
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) : 523 - 535
  • [9] Finite element prediction of surface strain and fracture strength at the distal radius
    Edwards, W. Brent
    Troy, Karen L.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) : 290 - 298
  • [10] Simulating Distal Radius Fracture Strength Using Biomechanical Tests: A Modeling Study Examining the Influence of Boundary Conditions
    Edwards, W. Brent
    Troy, Karen L.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (11):