To examine the effects of firefighting personal protective ensemble (PPE) and self-contained breathing apparatus (SCBA) on exercise performance, 12 males completed two randomly ordered, graded exercise treadmill tests (GXTPPE and GXT(PT)). Maximal oxygen consumption (VO2max) during GXTPPE was 17.3% lower than the GXTPT in regular exercise clothing (43.0 +/- 5.7 vs. 52.4 +/- 8.5 ml/kg per min, respectively). The lower VO2max during the PPE condition was significantly related (r = 0.81, p < 0.05) to attenuated peak ventilation (142.8 +/- 18.0 vs. 167.1 +/- 15.61/min), which was attributed to a significant reduction in tidal volume (2.6 +/- 10.4 vs. 3.2 +/- 0.41). Breathing frequency at peak exercise was unchanged (55 +/- 7 vs. 53 +/- 7 breaths/min). The results of this investigation demonstrate that PPE and the SCBA have a negative impact on VO2max. These factors must be considered when evaluating aerobic demands of fire suppression work and the fitness levels of firefighters.
引用
收藏
页码:911 / 920
页数:10
相关论文
共 27 条
[1]   Characterization of the metabolic demands of simulated shipboard Royal Navy fire-fighting tasks [J].
Bilzon, JLJ ;
Scarpello, EG ;
Smith, CV ;
Ravenhill, NA ;
Rayson, MP .
ERGONOMICS, 2001, 44 (08) :766-780
[2]  
Davis PO., 1975, INT FIRE CHIEF, V41, P10
[3]  
Donovan K, 1998, CONTEMPORARY ERGONOMICS 1998, P535
[4]   ENERGY-COST OF STEPPING IN PROTECTIVE CLOTHING ENSEMBLES [J].
DUGGAN, A .
ERGONOMICS, 1988, 31 (01) :3-11
[5]   The influence of the self-contained breathing apparatus (SCBA) on ventilatory function and maximal exercise [J].
Eves, ND ;
Jones, RL ;
Petersen, SR .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2005, 30 (05) :507-519
[6]   Hyperoxia improves maximal exercise with the self-contained breathing apparatus (SCBA) [J].
Eves, ND ;
Petersen, SR ;
Jones, RL .
ERGONOMICS, 2002, 45 (12) :829-839
[7]  
GLEDHILL N, 1992, CAN J SPORT SCI, V17, P207
[8]  
GLEDHILL N, 1992, CAN J SPORT SCI, V17, P199
[9]   COMPARISON BETWEEN LOAD CARRIAGE AND GRADE WALKING ON A TREADMILL [J].
GORDON, MJ ;
GOSLIN, BR ;
GRAHAM, T ;
HOARE, J .
ERGONOMICS, 1983, 26 (03) :289-298
[10]   OCCUPATIONAL-HEALTH CONCERNS OF FIREFIGHTING [J].
GUIDOTTI, TL ;
CLOUGH, VM .
ANNUAL REVIEW OF PUBLIC HEALTH, 1992, 13 :151-171