A Simple Approach for Experimental Characterization and Validation of Proton Pencil Beam Profiles

被引:13
|
作者
Stasica, Paulina [1 ,2 ]
Baran, Jakub [1 ]
Granja, Carlos [3 ]
Krah, Nils [4 ,5 ]
Korcyl, Grzegorz [6 ]
Oancea, Cristina [3 ]
Pawlik-Niedzwiecka, Monika [1 ,6 ]
Niedzwiecki, Szymon [6 ]
Rydygier, Marzena [7 ]
Schiavi, Angelo [8 ]
Rucinski, Antoni [1 ]
Gajewski, Jan [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, Proton Radiotherapy Grp NZ62, Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Krakow, Poland
[3] ADVACAM, Prague, Czech Republic
[4] Univ Lyon, CNRS, CREATIS, UMR 5220, Lyon, France
[5] Univ Lyon, CNRS, IP2I, UMR 5822, Lyon, France
[6] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, Krakow, Poland
[7] Polish Acad Sci, Inst Nucl Phys, Cyclotron Ctr Bronowice, Krakow, Poland
[8] Sapienza Univ Rome, Dept Basic & Appl Sci Engn, Rome, Italy
来源
FRONTIERS IN PHYSICS | 2020年 / 8卷
关键词
proton therapy; dose; semiconductor pixel detector; Timepix detector; Monte Carlo simulation; MONTE-CARLO CODE; TIMEPIX DETECTOR; SCANNED PROTON; PIXEL DETECTOR; X-RAY; THERAPY; DOSIMETRY; RECALCULATION; CAMERA; TOOL;
D O I
10.3389/fphy.2020.00346
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A precise characterization of therapeutic proton pencil beams is essential for the commissioning of any treatment planning system (TPS). The dose profile characterization includes measurement of the beam lateral dose profile in the beam core and far from the beam core, in the so called low-dose envelope, and requires a sophisticated detection system with a few orders of magnitude dynamic range. We propose the use of a single-quantum-sensitive MiniPix Timepix detector, along with an in-house-designed holder to perform measurements of the pencil beam dose profile in air and in water. We validated the manufacturer calibration of the MiniPix Timepix detector in proton beams of various energies and compared the deposited energy spectra to Monte Carlo (MC) simulations. The precision of the lateral dose profile measurements has been systematically validated against Krakow proton facility commissioning data and dose profile simulations performed with MC codes Gate/Geant4 and Fred. We obtained an excellent agreement between MiniPix Timepix measurements and simulations demonstrating the feasibility of the system for a simple characterization and validation of proton pencil beams. The proposed approach can be implemented at any proton therapy facility to acquire experimental data needed to commission and validate analytical and MC-based TPS.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzles
    Lin, Liyong
    Ainsley, Christopher G.
    Solberg, Timothy D.
    McDonough, James E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02) : 493 - 504
  • [2] Experimental characterization of two-dimensional pencil beam scanning proton spot profiles
    Lin, Liyong
    Ainsley, Christopher G.
    McDonough, James E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (17) : 6193 - 6204
  • [3] Comprehensive characterization of proton pencil beam profiles using a novel couch-mounted 2D strip detector system
    Huang, Hsiao-Chieh
    Chen, Hsien-Hsin
    Lin, Chih-Hsun
    Chang, Fu-Xiong
    Kao, Wei-Heng
    Chen, Po-Jui
    Chao, Tsi-Chian
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [4] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [5] Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Schwarz, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21) : 8601 - 8619
  • [6] Development and Validation of an Optimal GATE Model for Pencil Beam Scanning (PBS) Proton Beam Delivery
    Asadi, Ali
    Varnaseri, Seraj
    Moshiri, Shirin
    Akhavanallaf, Azadeh
    Arabi, Hossein
    Zaidi, Habib
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 471 - 474
  • [7] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05)
  • [8] Experimental characterisation of a proton kernel model for pencil beam scanning techniques
    De Marzi, L.
    Da Fonseca, A.
    Moignier, C.
    Patriarca, A.
    Goudjil, F.
    Mazal, A.
    Buvat, I
    Herault, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 195 - 203
  • [9] Experimental Validation of Low-Intensity Beam Extraction Mode for Proton Imaging at the Prometheus Synchrotron
    Pryanichnikov, A. A.
    Shemyakov, A. E.
    Belikhin, M. A.
    Zhogolev, P. B.
    Zavestovskaya, I. N.
    Chernyaev, A. P.
    PHYSICS OF ATOMIC NUCLEI, 2023, 86 (12) : 2732 - 2737
  • [10] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133