End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions

被引:60
作者
Bikker, Ido G. [1 ]
van Bommel, Jasper [1 ]
Miranda, Dinis Reis [1 ]
Bakker, Jan [1 ]
Gommers, Diederik [1 ]
机构
[1] Erasmus MC, Dept Intens Care Med, NL-3015 CE Rotterdam, Netherlands
来源
CRITICAL CARE | 2008年 / 12卷 / 06期
关键词
D O I
10.1186/cc7125
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Functional residual capacity (FRC) reference values are obtained from spontaneous breathing patients, and are measured in the sitting or standing position. During mechanical ventilation FRC is determined by the level of positive end-expiratory pressure (PEEP), and it is therefore better to speak of end-expiratory lung volume. Application of higher levels of PEEP leads to increased end-expiratory lung volume as a result of recruitment or further distention of already ventilated alveoli. The aim of this study was to measure end-expiratory lung volume in mechanically ventilated intensive care unit (ICU) patients with different types of lung pathology at different PEEP levels, and to compare them with predicted sitting FRC values, arterial oxygenation, and compliance values. Methods End-expiratory lung volume measurements were performed at PEEP levels reduced sequentially (15, 10 and then 5 cmH(2)O) in 45 mechanically ventilated patients divided into three groups according to pulmonary condition: normal lungs (group N), primary lung disorder (group P), and secondary lung disorder (group S). Results In all three groups, end-expiratory lung volume decreased significantly (P < 0.001) while PEEP decreased from 15 to 5 cmH(2)O, whereas the ratio of arterial oxygen tension to inspired oxygen fraction did not change. At 5 cmH(2)O PEEP, end-expiratory lung volume was 31, 20, and 17 ml/kg predicted body weight in groups N, P, and S, respectively. These measured values were only 66%, 42%, and 34% of the predicted sitting FRC. A correlation between change in end-expiratory lung volume and change in dynamic compliance was found in group S (P < 0.001; R-2 = 0.52), but not in the other groups. Conclusions End-expiratory lung volume measured at 5 cmH(2)O PEEP was markedly lower than predicted sitting FRC values in all groups. Only in patients with secondary lung disorders were PEEP-induced changes in end-expiratory lung volume the result of derecruitment. In combination with compliance, end-expiratory lung volume can provide additional information to optimize the ventilator settings.
引用
收藏
页数:6
相关论文
共 17 条
[1]   Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome [J].
Cressoni, Massimo ;
Caironi, Pietro ;
Polli, Federico ;
Carlesso, Eleonora ;
Chiumello, Davide ;
Cadringher, Paolo ;
Quintel, Micheal ;
Ranieri, Vito Marco ;
Bugedo, Guillermo ;
Gattinoni, Luciano .
CRITICAL CARE MEDICINE, 2008, 36 (03) :669-675
[2]   Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method [J].
Di Marco, Fabiano ;
Sperti, Lidia Rota ;
Milan, Barbara ;
Stucchi, Riccardo ;
Centanni, Stefano ;
Brochard, Laurent ;
Fumagalli, Roberto .
INTENSIVE CARE MEDICINE, 2007, 33 (12) :2109-2115
[3]   Computed tomography and pulmonary measurements [J].
Drummond, GB .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (05) :665-671
[4]   AUTOMATED SULFUR-HEXAFLUORIDE WASHOUT FUNCTIONAL RESIDUAL CAPACITY MEASUREMENT SYSTEM FOR ANY MODE OF MECHANICAL VENTILATION AS WELL AS SPONTANEOUS RESPIRATION [J].
EAST, TD ;
WORTELBOER, PJM ;
VANARK, E ;
BLOEM, FH ;
PENG, L ;
PACE, NL ;
CRAPO, RO ;
DREWS, D ;
CLEMMER, TP .
CRITICAL CARE MEDICINE, 1990, 18 (01) :84-91
[5]   Automated evaluation of functional residual capacity by oxygen washout [J].
Eichler W. ;
Schumacher J. ;
Roth-Isigkeit A. ;
Braun J. ;
Kuppe H. ;
Klotz K.-F. .
Journal of Clinical Monitoring and Computing, 2002, 17 (3-4) :195-201
[6]   A SIMPLE METHOD TO ESTIMATE FUNCTIONAL RESIDUAL CAPACITY IN MECHANICALLY VENTILATED PATIENTS [J].
FRETSCHNER, R ;
DEUSCH, H ;
WEITNAUER, A ;
BRUNNER, JX .
INTENSIVE CARE MEDICINE, 1993, 19 (07) :372-376
[7]   What has computed tomography taught us about the acute respiratory distress syndrome? [J].
Gattinoni, L ;
Caironi, P ;
Pelosi, P ;
Goodman, LR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (09) :1701-1711
[8]   Acute respiratory distress syndrome caused by pulmonary and extrapulmonary disease - Different syndromes? [J].
Gattinoni, L ;
Pelosi, P ;
Suter, PM ;
Pedoto, A ;
Vercesi, P ;
Lissoni, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (01) :3-11
[9]   THE RECORDING OF FRC - IS IT OF IMPORTANCE AND CAN IT BE MADE SIMPLE [J].
HEDENSTIERNA, G .
INTENSIVE CARE MEDICINE, 1993, 19 (07) :365-366
[10]   NORMAL VALUES OF FUNCTIONAL RESIDUAL CAPACITY IN THE SITTING AND SUPINE POSITIONS [J].
IBANEZ, J ;
RAURICH, JM .
INTENSIVE CARE MEDICINE, 1982, 8 (04) :173-177