Imaging-Guided Percutaneous Biopsy of Pathologic Fractures: A Retrospective Analysis of 129 Cases

被引:41
作者
Datir, Abhijit [1 ]
Pechon, Pierre [2 ]
Saifuddin, Asif [1 ]
机构
[1] Royal Natl Orthopaed Hosp NHS Trust, Dept Radiol, Stanmore H47 4LP, Middx, England
[2] Royal Natl Orthopaed Hosp NHS Trust, Dept Orthopaed Surg, Stanmore H47 4LP, Middx, England
关键词
musculoskeletal lesions; needle core biopsy; pathologic fracture; soft-tissue mass; CORE-NEEDLE-BIOPSY; PRIMARY BONE-TUMORS; SOFT-TISSUE TUMORS; MUSCULOSKELETAL LESIONS; DIAGNOSTIC YIELD; ACCURACY; NEOPLASMS; HAZARDS;
D O I
10.2214/AJR.08.1823
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to determine the diagnostic performance of imaging-guided percutaneous needle core biopsy and the factors associated with a non-diagnostic biopsy in patients with a pathologic fracture of the appendicular skeleton. MATERIALS AND METHODS. A retrospective audit was performed of 129 consecutive patients presenting with a pathologic fracture. All patients underwent percutaneous needle core biopsy using CT (n = 98), fluoroscopy (n = 15), or ultrasound (n = 16) guidance. In all cases, either MRI or CT was available before biopsy to assess the presence and degree of the extraosseous tumor mass. The resulting sample was classified as diagnostic (group 1) or nondiagnostic (group 2) on histopathologic study. Diagnostic performance was evaluated on the basis of the diagnostic yield and the diagnostic accuracy, and these were related to the site of the lesion and presence or absence of an extraosseous mass. RESULTS. Ninety-nine masses (77%) were classified as group 1 and 30 (23%) as group 2. The average cross-sectional diameter of lesions in group 1 was 5.7 x 5.9 cm. Of the 30 lesions composing group 2, no soft-tissue component was identified on prebiopsy cross-sectional imaging in 27 lesions (90%), but the remaining three (10%) showed a smaller extraosseous soft-tissue component compared with the lesions in group 1. CONCLUSION. Imaging-guided core biopsy is a reliable method for obtaining a tissue diagnosis in pathologic fracture of the appendicular skeleton with a high rate of accuracy. However, those lesions that are purely intraosseous or have only very small extraosseous components are more likely to be associated with a nondiagnostic biopsy and should be considered for a primary open procedure.
引用
收藏
页码:504 / 508
页数:5
相关论文
共 28 条
  • [1] Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours
    Altuntas, AO
    Slavin, J
    Smith, PJ
    Schlict, SM
    Powell, GJ
    Ngan, S
    Toner, G
    Choong, PFM
    [J]. ANZ JOURNAL OF SURGERY, 2005, 75 (04) : 187 - 191
  • [2] Surgical biopsy with intra-operative frozen section - An accurate and cost-effective method for diagnosis of musculoskeletal sarcomas
    Ashford, R. U.
    McCarthy, S. W.
    Scolyer, R. A.
    Bonar, S. F.
    Karim, R. Z.
    Stalley, P. D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (09): : 1207 - 1211
  • [3] AYALA AG, 1989, PATHOL ANNU, V24, P219
  • [4] PRIMARY BONE-TUMORS - PERCUTANEOUS NEEDLE-BIOPSY - RADIOLOGIC-PATHOLOGIC STUDY OF 222 BIOPSIES
    AYALA, AG
    ZORNOSA, J
    [J]. RADIOLOGY, 1983, 149 (03) : 675 - 679
  • [5] Magnetic resonance imaging-guided percutaneous biopsy of musculoskeletal lesions
    Carrino, John A.
    Khurana, Bharti
    Ready, John E.
    Silverman, Stuart G.
    Winalski, Carl S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10) : 2179 - 2187
  • [6] RECURRENCE OF AN OSTEOSARCOMA IN A NEEDLE-BIOPSY TRACK
    DAVIES, NM
    LIVESLEY, PJ
    CANNON, SR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (06): : 977 - 978
  • [7] DENHEETEN GJ, 1985, J SURG ONCOL, V28, P247
  • [8] ASPIRATION BIOPSY OF PRIMARY NEOPLASMS OF BONE
    DOLLAHITE, HA
    TATUM, L
    MOINUDDIN, SM
    CARNESALE, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (08) : 1166 - 1169
  • [9] Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms
    Dupuy, DE
    Rosenberg, AE
    Punyaratabandhu, T
    Tan, MH
    Mankin, HJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 759 - 762
  • [10] PERCUTANEOUS NEEDLE-BIOPSY OF MUSCULOSKELETAL LESIONS .2. COST-EFFECTIVENESS
    FRASERHILL, MA
    RENFREW, DL
    HILSENRATH, PE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (04) : 813 - 818