Beat-to-Beat Continuous Blood Pressure Estimation Using Bidirectional Long Short-Term Memory Network

被引:29
作者
Lee, Dongseok [1 ]
Kwon, Hyunbin [1 ,2 ]
Son, Dongyeon [1 ]
Eom, Heesang [3 ]
Park, Cheolsoo [3 ]
Lim, Yonggyu [4 ]
Seo, Chulhun [5 ]
Park, Kwangsuk [2 ,6 ]
机构
[1] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
[2] Seoul Natl Univ, Inst Med & Biol Engn, Med Res Ctr, Seoul 03080, South Korea
[3] Kwangwoon Univ, Dept Comp Engn, Seoul 01897, South Korea
[4] Sangji Univ, Dept Oriental Biomed Engn, Wonju 26339, South Korea
[5] Soongsil Univ, Sch Elect Engn, Seoul 06978, South Korea
[6] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Seoul 03080, South Korea
基金
新加坡国家研究基金会;
关键词
cuffless blood pressure; ballistocardiogram; long short-term memory; general blood pressure estimation; TRANSIT-TIME TECHNIQUE;
D O I
10.3390/s21010096
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous blood pressure (BP) monitoring is important for patients with hypertension. However, BP measurement with a cuff may be cumbersome for the patient. To overcome this limitation, various studies have suggested cuffless BP estimation models using deep learning algorithms. A generalized model should be considered to decrease the training time, and the model reproducibility should be taken into account in multi-day scenarios. In this study, a BP estimation model with a bidirectional long short-term memory network is proposed. The features are extracted from the electrocardiogram, photoplethysmogram, and ballistocardiogram. The leave-one-subject-out (LOSO) method is incorporated to generalize the model and fine-tuning is applied. The model was evaluated using one-day and multi-day tests. The proposed model achieved a mean absolute error (MAE) of 2.56 and 2.05 mmHg for the systolic and diastolic BP (SBP and DBP), respectively, in the one-day test. Moreover, the results demonstrated that the LOSO method with fine-tuning was more compatible in the multi-day test. The MAE values of the model were 5.82 and 5.24 mmHg for the SBP and DBP, respectively.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 24 条
[1]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[2]   Obstructive sleep apnoea detection using convolutional neural network based deep learning framework [J].
Dey D. ;
Chaudhuri S. ;
Munshi S. .
Biomedical Engineering Letters, 2018, 8 (1) :95-100
[3]   Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio [J].
Ding, Xiao-Rong ;
Zhang, Yuan-Ting ;
Liu, Jing ;
Dai, Wen-Xuan ;
Tsang, Hon Ki .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) :964-972
[4]   Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm [J].
Ding, Xiaorong ;
Zhang, Yuan-Ting .
BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) :37-52
[5]   End-To-End Deep Learning Architecture for Continuous Blood Pressure Estimation Using Attention Mechanism [J].
Eom, Heesang ;
Lee, Dongseok ;
Han, Seungwoo ;
Hariyani, Yuli Sun ;
Lim, Yonggyu ;
Sohn, Illsoo ;
Park, Kwangsuk ;
Park, Cheolsoo .
SENSORS, 2020, 20 (08)
[6]  
Graves A, 2012, STUD COMPUT INTELL, V385, P1, DOI [10.1162/neco.1997.9.1.1, 10.1007/978-3-642-24797-2]
[7]   Generalized Deep Neural Network Model for Cuffless Blood Pressure Estimation with Photoplethysmogram Signal Only [J].
Hsu, Yan-Cheng ;
Li, Yung-Hui ;
Chang, Ching-Chun ;
Harfiya, Latifa Nabila .
SENSORS, 2020, 20 (19) :1-18
[8]   MIMIC-III, a freely accessible critical care database [J].
Johnson, Alistair E. W. ;
Pollard, Tom J. ;
Shen, Lu ;
Lehman, Li-wei H. ;
Feng, Mengling ;
Ghassemi, Mohammad ;
Moody, Benjamin ;
Szolovits, Peter ;
Celi, Leo Anthony ;
Mark, Roger G. .
SCIENTIFIC DATA, 2016, 3
[9]   Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring [J].
Kachuee, Mohammad ;
Kiani, Mohammad Mahdi ;
Mohammadzade, Hoda ;
Shabany, Mahdi .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) :859-869
[10]   A Chair-Based Unconstrained/Nonintrusive Cuffless Blood Pressure Monitoring System Using a Two-Channel Ballistocardiogram [J].
Lee, Kwang Jin ;
Roh, Jongryun ;
Cho, Dongrae ;
Hyeong, Joonho ;
Kim, Sayup .
SENSORS, 2019, 19 (03)