Aluminum based metal-organic framework-polymer monolith in solid-phase microextraction of penicillins in river water and milk samples

被引:97
作者
Lirio, Stephen [1 ]
Liu, Wan-Ling [1 ]
Lin, Chen-Lan [1 ]
Lin, Chia-Her [1 ]
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, 200 Chung Pei Rd, Taoyuan 320, Taiwan
关键词
Solid-phase microextraction (SPME); Metal-organic framework (MOF); Penicillin; Polymer monolithic column; Milk; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; TANDEM MASS-SPECTROMETRY; ANTIBIOTIC-RESIDUES; GAS-CHROMATOGRAPHY; AQUEOUS-SOLUTIONS; WASTE-WATER; EXTRACTION; SEPARATION; CAPILLARY;
D O I
10.1016/j.chroma.2015.05.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, aluminum based metal-organic framework (Al-MOF)-organic polymer monoliths were prepared via microwave-assisted polymerization of ethylene dimethacrylate (EDMA), butyl methacrylate (BMA) with different weight percentages of Al-MOF (MIL-53; 37.5-62.5%) and subsequently utilized as sorbent in solid-phase microextraction (SPME) of penicillins (penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin). The Al-MOF-polymer was characterized using Fourier transform infrared (FTIR) spectroscopy, powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and SEM-energy-dispersive X-ray spectroscopy (SEM-EDS) to clarify the retained crystalline structure well as the homogeneous dispersion of Al-MOF (MIL-53) in polymer monolith. The developed Al-MOF-polymer (MIL-53) monolithic column was evaluated according to its extraction recovery of penicillins. Several parameters affecting the extraction recoveries of penicillins using fabricated Al-MOF-polymer (MIL-53) monolithic column including different MIL-53 weight percentages, column length, pH, desorption solvent, and mobile phase flow rate were investigated. For comparison, different Al-based MOFs (MIL-68, CYCU-4 and DUT-5) were fabricated using the optimized condition for MIL-53-polymer (sample matrix at pH 3, 200 mu L desorption volume using methanol, 37.5% of MOF, 4-cm column length at 0.100 mL min(-1) flow rate). Among all the Al-MOF-polymers, MIL-53(Al)-polymer still afforded the best extraction recovery for penicillins ranging from 90.5 to 95.7% for intra-day with less than 3.5% relative standard deviations (RSDs) and inter-day precision were in the range of 90.7-97.6% with less than 4.2% RSDs. Meanwhile, the recoveries for column-to-column were in the range of 89.5-93.5% (<3.4% RSDs) while 88.5-90.5% (<5.8% RSDs) for batch-to-batch (n=3). Under the optimal conditions, the limit of detections were in the range of 0.06-0.26 mu g L-1 and limit of quantifications between 0.20 and 0.87 mu g L-1. Finally, the MIL-53-polymer was applied for the extraction of penicillin in river water and milk by spiking trace-level penicillin for as low as 50 mu g L-1 and 100 mu g L-1 with recoveries ranging from 80.8% to 90.9% (<6.7% RSDs) in river water and 81.1% to 100.7% (<7.1% RSDs) in milk sample, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 245
页数:10
相关论文
共 55 条
[1]  
[Anonymous], 1990, OFF J EUR UNION, V23, P1
[2]   Coordination polymer adsorbent for matrix solid-phase dispersion extraction of pesticides during analysis of dehydrated Hyptis pectinata medicinal plant by GC/MS [J].
Aquino, Adriano ;
Wanderley, Kaline A. ;
Paiva-Santos, Carlos de Oliveira ;
de Sa, Gilberto F. ;
Alexandre, Marcelo da R. ;
Junior, Severino A. ;
Navickiene, Sandro .
TALANTA, 2010, 83 (02) :631-636
[3]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]   Fast screening methods to detect antibiotic residues in food samples [J].
Chafer-Pericas, Consuelo ;
Maquieira, Angel ;
Puchades, Rosa .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (09) :1038-1049
[5]   Metal-Organic-Framework-Based Tandem Molecular Sieves as a Dual Platform for Selective Microextraction and High-Resolution Gas Chromatographic Separation of n-Alkanes in Complex Matrixes [J].
Chang, Na ;
Gu, Zhi-Yuan ;
Wang, He-Fang ;
Yan, Xiu-Ping .
ANALYTICAL CHEMISTRY, 2011, 83 (18) :7094-7101
[6]   An amperometric penicillin biosensor with enhanced sensitivity based on co-immobilization of carbon nanotubes, hematein, and β-lactamase on glassy carbon electrode [J].
Chen, Bi ;
Ma, Ming ;
Su, Xiaoli .
ANALYTICA CHIMICA ACTA, 2010, 674 (01) :89-95
[7]   Metal-organic framework MIL-53(Al) as a solid-phase microextraction adsorbent for the determination of 16 polycyclic aromatic hydrocarbons in water samples by gas chromatography-tandem mass spectrometry [J].
Chen, Xiang-Feng ;
Zang, Hao ;
Wang, Xia ;
Cheng, Jian-Guang ;
Zhao, Ru-Song ;
Cheng, Chuan-Ge ;
Lu, Xiao-Qing .
ANALYST, 2012, 137 (22) :5411-5419
[8]   In Situ Hydrothermal Growth of Metal-Organic Framework 199 Films on Stainless Steel Fibers for Solid-Phase Microextraction of Gaseous Benzene Homologues [J].
Cui, Xiao-Yan ;
Gu, Zhi-Yuan ;
Jiang, Dong-Qing ;
Li, Yan ;
Wang, He-Fang ;
Yan, Xiu-Ping .
ANALYTICAL CHEMISTRY, 2009, 81 (23) :9771-9777
[9]   Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography [J].
Eisert, R ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3140-3147
[10]   In-tube solid phase microextraction using a β-cyclodextrin coated capillary coupled to high performance liquid chromatography for determination of non-steroidal anti-inflammatory drugs in urine samples [J].
Fan, Y ;
Feng, YQ ;
Da, SL ;
Wang, ZH .
TALANTA, 2005, 65 (01) :111-117