Noninvasive Mapping of Premature Ventricular Contractions by Merging Magnetocardiography and Computed Tomography

被引:18
作者
Aita, Satoshi [1 ]
Ogata, Kuniomi [2 ]
Yoshida, Kentaro [1 ,3 ]
Inaba, Takeshi [1 ]
Kosuge, Hisanori [1 ,4 ]
Machino, Takeshi [1 ]
Tsumagari, Yasuaki [1 ]
Hattori, Ai [1 ]
Ito, Yoko [1 ]
Komatsu, Yuki [1 ]
Sekihara, Kensuke [5 ]
Horigome, Hitoshi [6 ]
Aonuma, Kazutaka [1 ]
Nogami, Akihiko [1 ]
Kandori, Akihiko [2 ]
Ieda, Masaki [1 ]
机构
[1] Univ Tsukuba, Dept Cardiol, Tsukuba, Ibaraki, Japan
[2] Hitachi Ltd, Res & Dev Grp, Kokubunji, Tokyo, Japan
[3] Ibaraki Cent Hosp, Dept Cardiol, Kasama, Ibaraki, Japan
[4] Tsukuba Adv Imaging Ctr, Tsukuba, Ibaraki, Japan
[5] Signal Anal Inc, Hachioji, Tokyo, Japan
[6] Univ Tsukuba, Dept Pediat, Tsukuba, Ibaraki, Japan
关键词
catheter ablation; computed tomography; magnetocardiography; noninvasive mapping; premature ventricular contraction; OUTFLOW TRACT; ABLATION; ELECTROPHYSIOLOGY; TACHYCARDIAS; VALIDATION; ALGORITHM;
D O I
10.1016/j.jacep.2019.06.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study aimed to develop a novel premature ventricular contraction (PVC) mapping method to predict PVC origins in whole ventricles by merging a magnetocardiography (MCG) image with a cardiac computed tomography (CT) image. BACKGROUND MCG can noninvasivety discriminate PVCs originating from the aortic sinus cusp from those originating from the right ventricular outflow tract. METHODS This study was composed of 22 candidates referred for catheter ablation of idiopathic PVCs. MCG and CT were performed the same day before ablation. Estimated origins by MCG-CT imaging using the recursive null steering spatial filter algorithm were compared with origins determined by electroanatomic mapping (CARTO, Biosense Webster, Inc., Diamond Bar, California) during the ablation procedure. Radiopaque acrylic markers for the CT scan and coil markers generating a weak magnetic field during MCG measurements were used as reference markers to merge the 2 images 3-dimensionally. RESULTS PVC origins were determined by endocardial and epicardial mapping and ablation results in 18 (86%) patients (right ventricular outflow tract in 10 patients, aortic sinus cusp in 2 patients, interventricular septum in 1 patient, near His bundle in 1 patient, right ventricular free wall in 1 patient, and left ventricular free watt in 3 patients). Estimated origins by MCG-CT imaging matched the origins determined during the procedure in 94% (17 of 18) of patients, whereas the electrocardiography algorithms were accurate in only 56% (10 of 18). Discrimination of an epicardium versus an endocardium or right- versus left-sided septum was successful in 3 of 4 patients (75%). CONCLUSIONS The diagnostic accuracy of noninvasive MCG-CT mapping was high enough to allow clinical use to predict the site of PVC origins in the whole ventricles. (C) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1144 / 1157
页数:14
相关论文
共 23 条
[1]   Effect of electrocardiographic lead placement on localization of outflow tract tachycardias [J].
Anter, Elad ;
Frankel, David S. ;
Marchlinski, Francis E. ;
Dixit, Sanjay .
HEART RHYTHM, 2012, 9 (05) :697-703
[2]   Confirmation of Novel Noninvasive High-Density Electrocardiographic Mapping With Electrophysiology Study Implications for Therapy [J].
Cakulev, Ivan ;
Sahadevan, Jayakumar ;
Arruda, Mauricio ;
Goldstein, Robert N. ;
Hong, Mauricio ;
Intini, Anselma ;
Mackall, Judith A. ;
Stambler, Bruce S. ;
Ramanathan, Charu ;
Jia, Ping ;
Strom, Maria ;
Waldo, Albert L. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :68-75
[3]   Electrocardiographic patterns of superior right ventricular outflow tract tachycardias: Distinguishing septal and free-wall sites of origin [J].
Dixit, S ;
Gerstenfeld, EP ;
Callans, DJ ;
Marchlinski, FE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) :1-7
[4]   Performance and limitations of noninvasive cardiac activation mapping [J].
Duchateau, Josselin ;
Sacher, Frederic ;
Pambrun, Thomas ;
Derval, Nicolas ;
Chamorro-Servent, Judit ;
Denis, Arnaud ;
Ploux, Sylvain ;
Hocini, Meleze ;
Jais, Pierre ;
Bernus, Olivier ;
Haissaguerre, Michel ;
Dubois, Remi .
HEART RHYTHM, 2019, 16 (03) :435-442
[5]   Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital [J].
Inaba, T. ;
Nakazawa, Y. ;
Yoshida, K. ;
Kato, Y. ;
Hattori, A. ;
Kimura, T. ;
Hoshi, T. ;
Ishizu, T. ;
Seo, Y. ;
Sato, A. ;
Sekiguchi, Y. ;
Nogami, A. ;
Watanabe, S. ;
Horigome, H. ;
Kawakami, Y. ;
Aonuma, K. .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2017, 30 (11)
[6]   Development and validation of an ECG algorithm for identifying the optimal ablation site for idiopathic ventricular outflow tract tachycardia [J].
Ito, S ;
Tada, H ;
Naito, S ;
Kurosaki, K ;
Ueda, M ;
Hoshizaki, H ;
Miyamori, I ;
Oshima, S ;
Taniguchi, K ;
Nogami, A .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (12) :1280-1286
[7]   Development of a magnetocardiography-based algorithm for discrimination between ventricular arrhythmias originating from the right ventricular outflow tract and those originating from the aortic sinus cusp: A pilot study [J].
Ito, Yoko ;
Shiga, Keisuke ;
Yoshida, Kentaro ;
Ogata, Kuniomi ;
Kandori, Akihiko ;
Inaba, Takeshi ;
Nakazawa, Yoko ;
Sekiguchi, Yukio ;
Tada, Hiroshi ;
Sekihara, Kensuke ;
Aonuma, Kazutaka .
HEART RHYTHM, 2014, 11 (09) :1605-1612
[8]   Noninvasive electrocardiographic mapping to guide ablation of outflow tract ventricular arrhythmias [J].
Jamil-Copley, Shahnaz ;
Bokan, Ryan ;
Kojodjojo, Pipin ;
Qureshi, Norman ;
Koa-Wing, Michael ;
Hayat, Sajad ;
Kyriacou, Andreas ;
Sandler, Belinda ;
Sohaib, Afzal ;
Wright, Ian ;
Davies, David Wyn ;
Whinnett, Zachary ;
Peters, Nicholas S. ;
Kanagaratnam, Prapa ;
Lim, Phang Boon .
HEART RHYTHM, 2014, 11 (04) :587-594
[9]   Electrical space-time abnormalities of ventricular depolarization in patients with Brugada syndrome and patients with complete right-bundle branch blocks studied by magnetocardiography [J].
Kandori, A ;
Miyashita, T ;
Ogata, K ;
Shimizu, W ;
Yokokawa, M ;
Kamakura, S ;
Miyatake, K ;
Tsukada, K ;
Yamada, S ;
Watanabe, S ;
Yamaguchi, I .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (01) :15-20
[10]  
Kimata Akira, 2015, HeartRhythm Case Rep, V1, P103, DOI 10.1016/j.hrcr.2014.12.007