Characterization of the thickness of the tear film lipid layer using high resolution microscopy

被引:21
作者
Bai, Yuqiang [1 ]
Ngo, William [1 ]
Nichols, Jason J. [1 ]
机构
[1] Univ Alabama Birmingham, Sch Optometry, Dept Optometry & Vis Sci, 1716 Univ Blvd, Birmingham, AL 35223 USA
关键词
Interferometry; Lipid layer thickness; Tear film; dry eye; EVAPORATION; SURFACE;
D O I
10.1016/j.jtos.2018.12.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Interferometry is an optical technique that have been used to quantify the lipid layer of the precorneal tear film, and to investigate the relationship between lipid layer thickness and tear film evaporation. However, the relationship between lipid layer thickness and the rate of evaporation is far from consistent. One possible reason is the inherent limit of contemporary interferometric systems, which employ objectives with relatively long depth of focus (DOF) (> 15 mu m or more), which tend to collect excessive extra-planar noise. This limitation may negatively affect the accuracy of the characterization and thickness measurement of the lipid layer. The current system incorporated an objective with limited DOF (similar to 1.5 mu m) into a custom-built optical microscope to image the tear film lipid layer in humans. An algorithm was also developed to process these images. One major outcome of this system is that thick lipid layers exhibit higher variation in thickness values than thin or normal-thickness lipid layers. The variations may reflect the structural differences of the lipid layer, which may offer a novel dimension to explain the missing correlation between lipid layer thickness and evaporation. In summary, the development of the high resolution microscopy system and associated data processing algorithm may provide new insights into the lipid layer structure, topography and their relation to the tear film evaporation rate.
引用
收藏
页码:356 / 359
页数:4
相关论文
共 22 条
[1]   Human tear film and meibum. Very long chain wax esters and (O-acyl)-omega-hydroxy fatty acids of meibum [J].
Butovich, Igor A. ;
Wojtowicz, Jadwiga C. ;
Molai, Mike .
JOURNAL OF LIPID RESEARCH, 2009, 50 (12) :2471-2485
[2]   Importance of the lipid layer in human tear film stability and evaporation [J].
Craig, JP ;
Tomlinson, A .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (01) :8-13
[3]   AN INSTRUMENT FOR INVIVO TEAR FILM INTERFEROMETRY [J].
DOANE, MG .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (06) :383-388
[4]  
Doane MG, 1998, TEAR FILM INTERFEROM, P297
[5]   Image-based quantitative analysis of tear film lipid layer thickness for meibomian gland evaluation [J].
Hwang, Hyeonha ;
Jeon, Hee-Jae ;
Yow, Kin Choong ;
Hwang, Ho Sik ;
Chung, EuiHeon .
BIOMEDICAL ENGINEERING ONLINE, 2017, 16
[6]   A spectral-discrimination method for tear-film lipid-layer thickness estimation from fringe pattern images [J].
Khamene, A ;
Negahdaripour, S ;
Tseng, SCG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (02) :249-258
[7]   Mechanisms, imaging and structure of tear film breakup [J].
King-Smith, P. Ewen ;
Begley, Carolyn G. ;
Braun, Richard J. .
OCULAR SURFACE, 2018, 16 (01) :4-30
[8]   Tear Film Interferometry and Corneal Surface Roughness [J].
King-Smith, P. Ewen ;
Kimball, Samuel H. ;
Nichols, Jason J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) :2614-2618
[9]   High Resolution Microscopy of the Lipid Layer of the Tear Film [J].
King-Smith, P. Ewen ;
Nichols, Jason J. ;
Braun, Richard J. ;
Nichols, Kelly K. .
OCULAR SURFACE, 2011, 9 (04) :197-211
[10]   Application of a Novel Interferometric Method to Investigate the Relation between Lipid Layer Thickness and Tear Film Thinning [J].
King-Smith, P. Ewen ;
Hinel, Erich A. ;
Nichols, Jason J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) :2418-2423