Development of an Air Pneumatic Suspension System for Transtibial Prostheses

被引:29
作者
Pirouzi, Gholamhossein [1 ]
Abu Osman, Noor Azuan [1 ]
Oshkour, Azim Ataollahi [2 ]
Ali, Sadeeq [1 ]
Gholizadeh, Hossein [1 ]
Abas, Wan A. B. Wan [1 ]
机构
[1] Univ Malaya, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
关键词
air pneumatic system; semiconductor pressure sensor; socket design; pressure distribution; socket-stump interface; adjustability; FINITE-ELEMENT MODEL; RESIDUAL LIMB; INTERFACE PRESSURES; SLEEVE SUSPENSION; SOCKET INTERFACE; PIN SUSPENSION; AMPUTEES; LINER; STRESSES; WALKING;
D O I
10.3390/s140916754
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
引用
收藏
页码:16754 / 16765
页数:12
相关论文
共 43 条
[1]   Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction [J].
Ali, Sadeeq ;
Abu Osman, Noor Azuan ;
Mortaza, Niyousha ;
Eshraghi, Arezoo ;
Gholizadeh, Hossein ;
Abas, Wan Abu Bakar Bin Wan .
CLINICAL BIOMECHANICS, 2012, 27 (09) :943-948
[2]  
[Anonymous], 2001, JPO J PROSTHETICS OR
[3]   Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses [J].
Baars, ECT ;
Geertzen, JHB .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (01) :27-37
[4]   Comparison of interface pressures with pin and suction suspension systems [J].
Beil, TL ;
Street, GM .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2004, 41 (6A) :821-828
[5]  
Breakey J.W., 1973, Orthotics and Prosthetics, V27, P14
[6]  
Buis AWP, 1997, PROSTHET ORTHOT INT, V21, P179
[7]  
Center A. T., PUMP IT
[8]  
Charlesh H., 1979, PROSTHET ORTHOT INT, V33, P1
[9]  
CHINO N, 1975, ARCH PHYS MED REHAB, V56, P22
[10]   Quantification of prosthetic outcomes: Elastomeric gel liner with locking pin suspension versus polyethylene foam liner with neoprene sleeve suspension [J].
Coleman, KL ;
Boone, DA ;
Laing, LS ;
Mathews, DE ;
Smith, DG .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2004, 41 (04) :591-602