Potentiometric biosensor for urea determination in milk

被引:121
|
作者
Trivedi, U. B. [2 ]
Lakshminarayana, D. [2 ]
Kothari, I. L. [3 ]
Patel, N. G. [4 ]
Kapse, H. N. [5 ]
Makhija, K. K. [2 ]
Patel, R. B. [2 ]
Panchal, C. J. [1 ]
机构
[1] Maharaja Sayajirao Univ Baroda, Fac Engn & Technol, Dept Appl Phys, Vadodara 390001, Gujarat, India
[2] Sardar Patel Univ, Dept Elect, Vallabh Vidyanagar 388120, Gujarat, India
[3] Sardar Patel Univ, Dept Biosci, Vallabh Vidyanagar 388120, Gujarat, India
[4] Univ N Florida, Dept Chem & Phys, Jacksonville, FL USA
[5] Inst Sci & Technol Adv Studies & Res ISTAR, Vallabh Vidyanagar 388120, Gujarat, India
关键词
Potentiometry; Biosensor; Urea; Ion sensitive electrode; Urease; Polymer matrix; Milk; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; CARBOXYLIC-ACIDS; WIRE ELECTRODES; NITROGEN; COWS; HYDROLYSIS; DETECTOR; SAMPLES; IONS;
D O I
10.1016/j.snb.2009.04.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric urea sensitive biosensor, using a NH4+ ion sensitive electrode in double matrix membrane (DMM) technology as the transducer, has been described. Thick film screen printing technique was utilized for the fabrication of the basal conducting track of the potentiometric electrode and also for the development of Ag/AgCl reference electrode. The ion sensitive polymer matrix membrane could be formed in the presence of an electrochemically inert filter paper. The electrochemical response behavior of the NH4+ ion sensitive electrode has been studied initially. Later, a urea biosensor has been developed by immobilizing the urease enzyme, through entrapping, onto the ion sensitive membrane using a polymer matrix of poly(carbamoylsulphonate) (PCS) and polyethyleneimine (PEI). The urea biosensor responded rapidly and in a stable manner to the changes in the test urea concentrations. The sensor exhibited a detection limit of 2.5 x 10(-5) mol/L The average slope in the linear range has been found to be 51.7 +/- 0.5 mV/decade. The biosensor system has, then, been tested for the detection of urea levels in the real samples of milk. A good agreement could be observed between the urea concentrations detected by the developed biosensor and the spectrophotometric technique. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [1] Potentiometric biosensor for determination of urea in milk using immobilized Arthrobacter creatinolyticus urease
    Ramesh, Rajendran
    Puhazhendi, Puhazhselvan
    Kumar, Jitendra
    Gowthaman, Marichetti Kuppuswami
    D'Souza, Stanislaus Francis
    Kamini, Numbi Ramudu
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 786 - 792
  • [2] Urease immobilized potentiometric biosensor for determination of urea
    Sihombing, Kawan
    Tamba, Monica Chrisdayanti
    Marbun, Winry Sulistiani
    Situmorang, Manihar
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2018, 57 (02): : 175 - 180
  • [3] Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor
    Krawczyk, TKV
    Moszczynska, T
    Trojanowicz, M
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12): : 681 - 691
  • [4] ENZYME SENSOR SYSTEM FOR POTENTIOMETRIC UREA DETERMINATION IN SERUM AND MILK
    HAMANN, H
    KUHN, M
    BOTTCHER, N
    SCHELLER, F
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 209 (01): : 69 - 76
  • [5] THE POTENTIOMETRIC UREA BIOSENSOR USING CHITOSAN MEMBRANE
    Mulyasuryani, Ani
    Roosdiana, Anna
    Srihardyastutie, Arie
    INDONESIAN JOURNAL OF CHEMISTRY, 2010, 10 (02) : 162 - 166
  • [6] Wearable potentiometric biosensor for analysis of urea in sweat
    Ibanez-Redin, Gisela
    Cagnani, Giovana Rosso
    Gomes, Nathalia O.
    Raymundo-Pereira, Paulo A.
    Machado, Sergio A. S.
    Gutierrez, Marco Antonio
    Krieger, Jose Eduardo
    Oliveira, Osvaldo N.
    BIOSENSORS & BIOELECTRONICS, 2023, 223
  • [7] A Urea Potentiometric Biosensor Based on a Thiophene Copolymer
    Lai, Cheng-Yuan
    Foot, Peter J. S.
    Brown, John W.
    Spearman, Peter
    BIOSENSORS-BASEL, 2017, 7 (01):
  • [8] Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
    Marchenko, S. V.
    Kucherenko, I. S.
    Hereshko, A. N.
    Panasiuk, I. V.
    Soldatkin, O. O.
    El'skaya, A. V.
    Soldatkin, A. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 981 - 986
  • [9] Potentiometric biosensor for urea based on electropolymerized electroinactive polypyrrole
    Komaba, S
    Seyama, M
    Momma, T
    Osaka, T
    ELECTROCHIMICA ACTA, 1997, 42 (03) : 383 - 388
  • [10] A PRACTICAL APPROACH TO CHEMICAL SENSORS THROUGH POTENTIOMETRIC TRANSDUCERS - DETERMINATION OF UREA IN SERUM BY MEANS OF A BIOSENSOR
    MARTINEZFABREGAS, E
    ALEGRET, S
    JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (03) : A67 - A70