Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging

被引:50
作者
Atsu, Saadet Saglam [1 ]
Aksan, M. Emin
Bulut, Ali Can [1 ]
机构
[1] Kirikkale Univ, Fac Dent, Dept Prosthodont, Kirikkale, Turkey
关键词
ceramic-reinforced polyetheretherketone; chewing simulator; dental implant abutments; fracture resistance; lithium disilicate crowns; titanium; zirconia; RESIN VENEERING MATERIALS; FAILURE MODE; JOINT STABILITY; BOND STRENGTH; SINGLE CROWNS; SURVIVAL RATE; ORAL IMPLANT; MORSE-TAPER; BITE FORCE; WEAR;
D O I
10.11607/jomi.7036
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to compare the fracture resistances and the fracture types of titanium, zirconia, and ceramic-reinforced polyetheretherketone (PEEK) implant abutments supporting computer-aided design/computer-aided manufacturing (CAD/CAM) monolithic lithium disilicate ceramic crowns after in vitro dynamic loading and thermocycling aging. Materials and Methods: Three implant abutment (SKY Implant) groups-titanium (group Ti, control); zirconia with titanium base (group Zr); and ceramic-reinforced PEEK (BioHPP) with titanium base (group RPEEK); n = 12 each-were used. Thirty-six CAD/CAM monolithic lithium disilicate crowns (IPS e. max CAD) in the form of a maxillary central incisor were cemented with Panavia V5 on the abutments. The specimens were subjected to dynamic loading and thermocycling. Fracture resistances of the restorations were tested with a universal testing machine (0.5 mm/min), and their fracture patterns were analyzed. One-way analysis of variance (ANOVA) and Tukey post hoc test were used for statistical analyses (alpha = .05). Results: All samples survived after aging. The fracture strength values (mean +/- standard deviation) of the groups were as follows: group Ti, 787.8 +/- 120.9 N; group Zr, 623.9 +/- 97.4 N; and group RPEEK, 602.9 +/- 121 N. The fracture strengths were significantly higher in group Ti compared to groups Zr and RPEEK (P =.001). No significant difference was observed between groups Zr and RPEEK. Failures generally occurred due to fracture of the screw in group Ti, abutment and crown in group Zr, and crown in group RPEEK. Conclusion: Ceramic-reinforced PEEK abutments may be an alternative to zirconia abutments with a titanium base for single-implant restorations in the anterior region. However, there is need for further in vitro and clinical studies to evaluate the long-term performance of ceramic-reinforced PEEK abutments.
引用
收藏
页码:622 / 630
页数:9
相关论文
共 66 条
[11]   Evaluation of early resin luting cement damage induced by voids around a circular fiber post in a root canal treated premolar by integrating micro-CT, finite element analysis and fatigue testing [J].
Chang, Yen-Hsiang ;
Wang, Hsuan-Wen ;
Lin, Pei-Hsun ;
Lin, Chun-Li .
DENTAL MATERIALS, 2018, 34 (07) :1082-1088
[12]   FUNCTIONAL OCCLUSAL FORCES - INVESTIGATION BY TELEMETRY [J].
DEBOEVER, JA ;
MCCALL, WD ;
HOLDEN, S ;
ASH, MM .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (03) :326-333
[13]  
Della Bona A, 2008, J AM DENT ASSOC, V139, p8S
[14]   DEVELOPMENT OF AN ARTIFICIAL ORAL ENVIRONMENT FOR THE TESTING OF DENTAL RESTORATIVES - BI-AXIAL FORCE AND MOVEMENT CONTROL [J].
DELONG, R ;
DOUGLAS, WH .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (01) :32-36
[15]  
DeLong R, 1985, Dent Mater, V1, P238, DOI 10.1016/S0109-5641(85)80050-6
[16]   Comparison of fracture strength and failure mode of different ceramic implant abutments [J].
Elsayed, Adham ;
Wille, Sebastian ;
Al-Akhali, Majed ;
Kern, Matthias .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) :499-506
[17]   SCREW JOINT STABILITY AFTER THE APPLICATION OF RETORQUE IN IMPLANT-SUPPORTED DENTURES UNDER SIMULATED MASTICATORY CONDITIONS [J].
Farina, Ana Paula ;
Spazzin, Aloisio Oro ;
Xediek Consani, Rafael Leonardo ;
Mesquita, Marcelo Ferraz .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (06) :499-504
[18]   Biting and chewing in overdentures, full dentures, and natural dentitions [J].
Fontijn-Tekamp, FA ;
Slagter, AP ;
Van Der Bilt, A ;
Van 'T Hof, MA ;
Witter, DJ ;
Kalk, W ;
Jansen, JA .
JOURNAL OF DENTAL RESEARCH, 2000, 79 (07) :1519-1524
[19]   FRACTURE RESISTANCE OF TITANIUM AND ZIRCONIA ABUTMENTS: AN IN VITRO STUDY [J].
Foong, Jamie K. W. ;
Judge, Roy B. ;
Palamara, Joseph E. ;
Swain, Michael V. .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (05) :304-312
[20]   Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns [J].
Freitas, Amilcar C., Jr. ;
Bonfante, Estevam A. ;
Rocha, Eduardo P. ;
Silva, Nelson R. F. A. ;
Marotta, Leonard ;
Coelho, Paulo G. .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2011, 119 (04) :323-330