Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging

被引:50
作者
Atsu, Saadet Saglam [1 ]
Aksan, M. Emin
Bulut, Ali Can [1 ]
机构
[1] Kirikkale Univ, Fac Dent, Dept Prosthodont, Kirikkale, Turkey
关键词
ceramic-reinforced polyetheretherketone; chewing simulator; dental implant abutments; fracture resistance; lithium disilicate crowns; titanium; zirconia; RESIN VENEERING MATERIALS; FAILURE MODE; JOINT STABILITY; BOND STRENGTH; SINGLE CROWNS; SURVIVAL RATE; ORAL IMPLANT; MORSE-TAPER; BITE FORCE; WEAR;
D O I
10.11607/jomi.7036
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to compare the fracture resistances and the fracture types of titanium, zirconia, and ceramic-reinforced polyetheretherketone (PEEK) implant abutments supporting computer-aided design/computer-aided manufacturing (CAD/CAM) monolithic lithium disilicate ceramic crowns after in vitro dynamic loading and thermocycling aging. Materials and Methods: Three implant abutment (SKY Implant) groups-titanium (group Ti, control); zirconia with titanium base (group Zr); and ceramic-reinforced PEEK (BioHPP) with titanium base (group RPEEK); n = 12 each-were used. Thirty-six CAD/CAM monolithic lithium disilicate crowns (IPS e. max CAD) in the form of a maxillary central incisor were cemented with Panavia V5 on the abutments. The specimens were subjected to dynamic loading and thermocycling. Fracture resistances of the restorations were tested with a universal testing machine (0.5 mm/min), and their fracture patterns were analyzed. One-way analysis of variance (ANOVA) and Tukey post hoc test were used for statistical analyses (alpha = .05). Results: All samples survived after aging. The fracture strength values (mean +/- standard deviation) of the groups were as follows: group Ti, 787.8 +/- 120.9 N; group Zr, 623.9 +/- 97.4 N; and group RPEEK, 602.9 +/- 121 N. The fracture strengths were significantly higher in group Ti compared to groups Zr and RPEEK (P =.001). No significant difference was observed between groups Zr and RPEEK. Failures generally occurred due to fracture of the screw in group Ti, abutment and crown in group Zr, and crown in group RPEEK. Conclusion: Ceramic-reinforced PEEK abutments may be an alternative to zirconia abutments with a titanium base for single-implant restorations in the anterior region. However, there is need for further in vitro and clinical studies to evaluate the long-term performance of ceramic-reinforced PEEK abutments.
引用
收藏
页码:622 / 630
页数:9
相关论文
共 66 条
[1]  
AL-Rabab'ah M., 2017, J Prosthodont, V00, P1
[2]   Fracture resistance of zirconia-based implant abutments after artificial long-term aging [J].
Alsahhaf, Abdulaziz ;
Spies, Benedikt Christopher ;
Vach, Kirstin ;
Kohal, Ralf-Joachim .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 66 :224-232
[3]   Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin [J].
Atsu, Saadet Saglam ;
Kilicarslan, Mehmet A. ;
Kucukesmen, H. Cenker ;
Aka, P. Sema .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (06) :430-436
[4]   Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) :380-386
[5]   Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) :111-116
[6]  
Bechir ES, 2016, MATER PLAST, V53, P394
[7]  
Blunck U, 2007, J ADHES DENT, V9, P231
[8]   Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation [J].
Butz, F ;
Heydecke, G ;
Okutan, M ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (11) :838-843
[9]   A Pilot Study of Joint Stability at the Zirconium or Titanium Abutment/Titanium Implant Interface [J].
Cavusoglu, Yeliz ;
Akca, Kivanc ;
Gurbuz, Riza ;
Cehreli, Murat Cavit .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) :338-343
[10]   Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant:: influence of abutment design [J].
Çehreli, MC ;
Akça, K ;
Iplikçioglu, H ;
Sahin, S .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :459-465