Formaldehyde emission behavior of building materials: On-site measurements and modeling approach to predict indoor air pollution

被引:56
作者
Bourdin, Delphine [1 ,2 ]
Mocho, Pierre [3 ]
Desauziers, Valerie [1 ]
Plaisance, Herve [1 ]
机构
[1] Ecole Mines Ales, Pole RIME C2MA, F-64053 Pau 9, France
[2] NOBATEK, F-64600 Anglet, France
[3] Univ Pau & Pays Adour, Lab Therm Energet & Proc, F-64075 Pau, France
关键词
Formaldehyde; Indoor air quality; Building material; On-site emission cell; Box Model; CFD modeling; SPME; SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; PASSIVE FLUX SAMPLER; CFD SIMULATION; VOCS; VENTILATION; EXPOSURE; QUALITY; RATES;
D O I
10.1016/j.jhazmat.2014.07.065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this paper was to investigate formaldehyde emission behavior of building materials from on-site measurements of air phase concentration at material surface used as input data of a box model to estimate the indoor air pollution of a newly built classroom. The relevance of this approach was explored using CFD modeling. In this box model, the contribution of building materials to indoor air pollution was estimated with two parameters: the convective mass transfer coefficient in the material/air boundary layer and the on-site measurements of gas phase concentration at material surfaces. An experimental method based on an emission test chamber was developed to quantify this convective mass transfer coefficient. The on-site measurement of gas phase concentration at material surface was measured by coupling a home-made sampler to SPME. First results had shown an accurate estimation of indoor formaldehyde concentration in this classroom by using a simple box model. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 41 条
  • [1] AFSSET, 2009, 2004011 AFSSET
  • [2] AgBB, 2008, HLTH REL EV PROC VOL
  • [3] Sick buildings or not: Indoor air quality and health problems in schools
    Alsmo, Thomas
    Holmberg, Sture
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (06) : 548 - 555
  • [4] Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition
    An, Jae-Yoon
    Kim, Sumin
    Kim, Hyun-Joong
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 187 (1-3) : 44 - 51
  • [5] [Anonymous], 2006, EN ISO 16000-9
  • [6] [Anonymous], 2006, E74100 ASTM
  • [7] [Anonymous], 2006, 1600010 ISO
  • [8] Evaluated kinetic and photochemical data for atmospheric chemistry: Volume II - gas phase reactions of organic species
    Atkinson, R.
    Baulch, D. L.
    Cox, R. A.
    Crowley, J. N.
    Hampson, R. F.
    Hynes, R. G.
    Jenkin, M. E.
    Rossi, M. J.
    Troe, J.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2006, 6 : 3625 - 4055
  • [9] Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials
    Blondel, Alodie
    Plaisance, Herve
    [J]. ANALYTICAL METHODS, 2010, 2 (12) : 2032 - 2038
  • [10] Formaldehyde emission monitoring from a variety of solid wood, plywood, blockboard and flooring products manufactured for building and furnishing materials
    Boehm, Martin
    Salem, Mohamed Z. M.
    Srba, Jaromir
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2012, 221 : 68 - 79