Pool fire accident in an aboveground LFO tank storage: thermal analysis

被引:11
|
作者
Rebec, A. [1 ]
Plesec, P. [2 ]
Kolsek, J. [1 ]
机构
[1] ZAG, Slovenian Natl Bldg & Civil Engn Inst, Fire Lab & Fire Engn, SI-1000 Ljubljana, Slovenia
[2] ZAG, Slovenian Natl Bldg & Civil Engn Inst, Dept Bldg Phys, SI-1000 Ljubljana, Slovenia
关键词
Pool fire; LFO; Light fuel oil; Emissive power; Wind effect; Flame height; RADIATION; MODELS;
D O I
10.1016/j.firesaf.2014.05.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire in an aboveground light fuel oil (LFO) tank storage can cause surrounding tanks to heat up considerably. The incident usually does not result in a fire in the thermally exposed adjacent tanks. Nonetheless, their structural systems are at risk of either collapsing or plastically deforming. Prior to performing a complete structural analysis of the mechanical response of the exposed adjacent tanks, however, heat flux from the flames of the burning tank to its surroundings needs to be determined and the thermal profiles consequently established in the exposed tanks are to be defined. An adequate numerical procedure is proposed in this paper. In the latter, radiative characteristics of the flame body are first established by engaging a solid flame radiation model and then incident radiative heat flux entering the adjacent tank is calculated subsequently accounting for the tank's 'visibility' and atmospheric absorptivity. In support of the numerical analysis, experiments on 300 cm diameter LFO pans are presented and data from the literature are gathered. In the final part of the paper, a parametric study is shown exploring effects of the wind speed, distance between the tanks, and the level of the LFO fuel contained in the tanks. While the effects of wind speed and the distance between the tanks are evaluated significant the effects of the observed fuel levels are found to be irrelevant. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:135 / 150
页数:16
相关论文
共 50 条
  • [21] FDS simulation of the pool fire in the dichloropropane tank
    Xie, Fei
    Song, Wenhua
    Lv, Lingyue
    Chen, Zhen
    2012 FOURTH INTERNATIONAL CONFERENCE ON MULTIMEDIA INFORMATION NETWORKING AND SECURITY (MINES 2012), 2012, : 500 - 504
  • [22] A Dynamic Heat Transfer Model to Predict the Thermal Response of a Tank Exposed to a Pool Fire
    Lackman, Tomas
    Hallberg, Malin
    15TH INTERNATIONAL SYMPOSIUM ON LOSS PREVENTION AND SAFETY PROMOTION (LOSS 2016), 2016, 48 : 157 - 162
  • [23] Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
    Ramezanifar, Ehsan
    Gholamizadeh, Kamran
    Mohammadfam, Iraj
    Aliabadi, Mostafa Mirzaei
    PLOS ONE, 2023, 18 (03):
  • [24] Benefit analysis of CCHP with thermal storage tank
    Jiang, Xinfeng
    Zou, Bin
    2018 INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES (SEST), 2018,
  • [25] Aboveground storage tank bottom exterior CP system
    不详
    MATERIALS PERFORMANCE, 2007, 46 (05) : 35 - 35
  • [26] General rules for aboveground storage tank design and operation
    Amrouche, Y
    Davè, C
    Gursahani, K
    Lee, R
    Montemayor, L
    CHEMICAL ENGINEERING PROGRESS, 2002, 98 (12) : 54 - 58
  • [27] The time-to-failure assessment of large crude oil storage tank exposed to pool fire
    Wu, Zhuang
    Hou, Lei
    Wu, Shouzhi
    Wu, Xingguang
    Liu, Fangyuan
    FIRE SAFETY JOURNAL, 2020, 117
  • [29] NEPTUNE - ABOVEGROUND STORAGE TANK INSPECTION ROBOT SYSTEM
    SCHEMPF, H
    CHEMEL, B
    EVERETT, N
    IEEE ROBOTICS & AUTOMATION MAGAZINE, 1995, 2 (02) : 9 - 15
  • [30] Corrosion Failure of Bottom Plates of an Aboveground Storage Tank
    Mobin, M.
    Malik, A. U.
    Al-Fozan, S.
    Al-Muaili, F.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2007, 7 (01) : 18 - 22