Proposal and performance analysis of solar cogeneration system coupled with absorption heat pump

被引:15
作者
Li, Xing [1 ,2 ,3 ,4 ]
Wang, Zhifeng [1 ,2 ,3 ,4 ]
Yang, Ming [1 ,2 ,4 ]
Bai, Yakai [1 ,2 ,3 ,4 ]
Yuan, Guofeng [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Key Lab Solar Thermal Energy & Photovolta Syst, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Beijing Engn Res Ctr Solar Thermal Power, Beijing 100190, Peoples R China
关键词
Solar cogeneration system; Exergy analysis; Absorption heat pump; Regeneration process; Thermoeconomic investigation; DYNAMIC SIMULATION; HOT-WATER; POWER; RECOVERY; DESIGN; ENERGY; PLANT;
D O I
10.1016/j.applthermaleng.2019.113873
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a new kind of solar cogeneration system coupled with absorption heat pump (AHP) to recover condensate waste heat from exhaust of steam turbine in solar thermal power (STP) tower plant is proposed. Depending on mathematical models of the proposed system, several design parameters including direct normal irradiance (DNI), heat recovery ratio and improved power cycle are tested to evaluate their effects on the thermodynamic performance. Thermoeconomic investigations are also studied based on the existing AHP system installed in the pilot STP tower plant in Beijing. The results show that thermodynamic performance of the proposed system is improved due to energy and exergy contributions from steam storage tank (SST) and AHP. With the increase of DNI, the energy efficiency decreases accompanying with the increasing of exergy efficiency. As the condensate waste heat is completely recovered by AHP, the energy efficiency can reach up to 80.50%. Integrating with the improved regenerative cycle, the energy and exergy efficiencies can be increased from 16.90% to 17.17% and from 15.76% to 16.05%, respectively. Under the present base case, the unit heating cost decreases from 8.1 cent/kWh to 2.8 cent/kWh with the increase of operation time from 228 h to 2880 h.
引用
收藏
页数:14
相关论文
共 38 条
  • [1] Design of a small scale stand-alone solar thermal co-generation plant for an isolated region in Egypt
    Abdelhady, Suzan
    Borello, Domenico
    Tortora, Eileen
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 88 : 872 - 882
  • [2] Desalination using low grade heat in the process industry: Challenges and perspectives
    Ammar, Yasmine
    Li, Hanning
    Walsh, Conor
    Thornley, Patricia
    Sharifi, Vida
    Roskilly, Anthony P.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 48 : 446 - 457
  • [3] [Anonymous], 2011, FUNDAMENTALS ENG THE
  • [4] Opportunities for the integration of absorption heat pumps in the pulp and paper process
    Bakhtiari, Bahador
    Fradette, Louis
    Legros, Robert
    Paris, Jean
    [J]. ENERGY, 2010, 35 (12) : 4600 - 4606
  • [5] STUDY OF WASTE HEAT RECOVERY FROM STEAM TURBINE XHAUST FOR VAPOUR ABSORPTION SYSTEM IN SUGAR INDUSTRY
    Balaji, K.
    Ramkumar, R.
    [J]. INTERNATIONAL CONFERENCE ON MODELLING OPTIMIZATION AND COMPUTING, 2012, 38 : 1352 - 1356
  • [6] A review of studies on central receiver solar thermal power plants
    Behar, Omar
    Khellaf, Abdallah
    Mohammedi, Kamal
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 23 : 12 - 39
  • [7] 2ND LAW ANALYSIS AND SYNTHESIS OF SOLAR COLLECTOR SYSTEMS
    BEJAN, A
    KEARNEY, DW
    KREITH, F
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (01): : 23 - 28
  • [8] Bejan A., 1995, Thermal Design and Optimization
  • [9] Dai Yongqing, 1996, TECHNOLOGY APPL LIBR
  • [10] An assessment of solar-powered organic Rankine cycle systems for combined heating and power in UK domestic applications
    Freeman, James
    Hellgardt, Klaus
    Markides, Christos N.
    [J]. APPLIED ENERGY, 2015, 138 : 605 - 620