Effect of defects in externally bonded FRP reinforced concrete

被引:82
作者
Wan, Baolin [1 ]
Jiang, Cheng [2 ,4 ]
Wu, Yu-Fei [3 ,4 ]
机构
[1] Marquette Univ, Dept Civil Construct & Environm Engn, Milwaukee, WI 53233 USA
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] RMIT Univ, Sch Engn, Melbourne, Vic, Australia
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete; FRP; Cracking; Bond slip relationship; Defect; STRESS-STRAIN RELATIONSHIP; CONFINED CONCRETE; SLIP RELATIONSHIP; BEHAVIOR; CFRP; STRENGTH; MODELS; COMPOSITES; INTERFACES; COLUMNS;
D O I
10.1016/j.conbuildmat.2018.03.217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In practical engineering works, external bonding (EB) of fiber reinforced polymer (FRP) composite materials to concrete cannot be as perfect as in laboratory. Defects in bonding, therefore, cannot be avoided. An experimental program including single shear pull-out tests on EB-FRP concrete joints and three-point bending tests on reinforced concrete (RC) beams with/without EB-FRP was conducted. The effects of existing cracks in concrete with different spacing and widths, as well as FRP location relative to the centerline of specimen, were studied. Most of the specimens in the experimental program were prepared by unskilled personnel to simulate the "imperfect" workmanship. Test results show that EB-FRP joints with more than 10% concrete pulled off on the bond surface could have stable strength and ductility. Transverse offset of FRP from longitudinal center line does not have a significant effect on bond behavior. Existing cracks have a two-sided effect on bond-slip relationship. Cracking of concrete causes degradation of the bond slip relationship when crack width is large. However, cracking with smaller crack width could enhance the bond behavior to a certain degree. Existing cracks have limited influence on the load-deflection curves of FRP strengthened RC beams. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 76
页数:14
相关论文
共 41 条
[1]  
[Anonymous], 1998, Journal of Composites for Construction, V3, P138, DOI DOI 10.1061/(ASCE)1090-0268(1998)2:3(138)
[2]  
ASTM Subcommittee D20.10 on Mechanical Properties, 1995, STANDARD TEST METHOD
[3]   Cross-Sectional Unification on the Stress-Strain Model of Concrete Subjected to High Passive Confinement by Fiber-Reinforced Polymer [J].
Cao, Yu-Gui ;
Jiang, Cheng ;
Wu, Yu-Fei .
POLYMERS, 2016, 8 (05)
[4]   Stress-strain relationship of FRP confined concrete columns under combined axial load and bending moment [J].
Cao, Yugui ;
Wu, Yu-Fei ;
Jiang, Cheng .
COMPOSITES PART B-ENGINEERING, 2018, 134 :207-217
[5]   Compressive Behavior of CFRP-Confined Recycled Aggregate Concrete in Different-Sized Circular Sections [J].
Chen, G. M. ;
Zhang, J. J. ;
Jiang, T. ;
Lin, C. J. ;
He, Y. H. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (04)
[6]   Anchorage strength models for FRP and steel plates bonded to concrete [J].
Chen, JF ;
Teng, JG .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (07) :784-791
[7]   Environmental durability of externally bonded FRP materials intended for repair of concrete structures [J].
Cromwell, J. R. ;
Harries, K. A. ;
Shahrooz, B. M. .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (05) :2528-2539
[8]   Development of the nonlinear bond stress-slip model of fiber reinforced plastics sheet-concrete interfaces with a simple method [J].
Dai, JG ;
Ueda, T ;
Sato, Y .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :52-62
[9]  
Guan D. Z., 2016, J EARTHQUAKE ENG
[10]   A review of the present and future utilisation of FRP composites in the civil infrastructure with reference to their important in-service properties [J].
Hollaway, L. C. .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (12) :2419-2445