Fast Acquisition of Heart Rate in Noncontact Vital Sign Radar Measurement Using Time-Window-Variation Technique

被引:106
作者
Tu, Jianxuan [1 ]
Lin, Jenshan [1 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
Arctangent demodulation; complex signal demodulation (CSD); frequency spectrum resolution; heart rate (HR); noncontact continuous-wave (CW) Doppler radar vital sign detection; short-period time window; time window variation; DOPPLER RADAR; DEMODULATION; CLUTTER; SENSOR;
D O I
10.1109/TIM.2015.2479103
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fast acquisition of heart rate (HR) is a challenge in noncontact vital sign detection using a Doppler radar system. Most of the previous studies use long-period time windows to guarantee a sufficient frequency spectrum resolution for HR measurement using the peak searching method on the frequency spectrum. For fast acquisition of HR, the length of the time window is less than 5 s and the accuracy is significantly degraded due to insufficient spectrum resolution. For vital sign detection using complex signal demodulation (CSD), measuring HR variation becomes a difficult job due to respiration harmonic interference and insufficient frequency spectrum resolution. In this paper, a time-window-variation technique is developed for fast acquisition of HR from short-period time windows and measuring HR variation using CSD. Experiments are performed on four human subjects under controlled laboratory conditions by a 5.8-GHz continuous-wave Doppler radar vital sign detection system. The HR measurement results within 2-5-s time windows are compared by applying a simple fast Fourier transform (FFT) and peak searching method, a 10-s sliding-time-window FFT method, and the proposed method. The proposed method achieves the smallest average error among the three techniques. The proposed method has also proved to be able to measure HR variation using CSD.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 39 条
[1]   Measurement of Heart Rate Variability Using an Oscillometric Blood Pressure Monitor [J].
Ahmad, Saif ;
Bolic, Miodrag ;
Dajani, Hilmi ;
Groza, Voicu ;
Batkin, Izmail ;
Rajan, Sreeraman .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (10) :2575-2590
[2]   UNIFIED APPROACH TO SHORT-TIME FOURIER-ANALYSIS AND SYNTHESIS [J].
ALLEN, JB ;
RABINER, LR .
PROCEEDINGS OF THE IEEE, 1977, 65 (11) :1558-1564
[3]  
Almeida DLF, 2013, IEEE ENG MED BIO, P3278, DOI 10.1109/EMBC.2013.6610241
[4]  
[Anonymous], 2014, P 2014 IEEE MTT S IN
[5]   Compact Millimeter-Wave Sensor for Remote Monitoring of Vital Signs [J].
Bakhtiari, Sasan ;
Elmer, Thomas W., II ;
Cox, Nicholas M. ;
Gopalsami, Nachappa ;
Raptis, Appostolos C. ;
Liao, Shaolin ;
Mikhelson, Ilya ;
Sahakian, Alan V. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (03) :830-841
[6]   Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier [J].
Chen, KM ;
Huang, Y ;
Zhang, JP ;
Norman, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) :105-114
[7]   AN X-BAND MICROWAVE LIFE-DETECTION SYSTEM [J].
CHEN, KM ;
MISRA, D ;
WANG, H ;
CHUANG, HR ;
POSTOW, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (07) :697-701
[8]   0.5-μm CMOS implementation of analog heart-rate extraction with a robust peak detector [J].
Chen, Mingqi ;
Boric-Lubecke, Olga ;
Lubecke, Victor M. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (04) :690-698
[9]   AUTOMATIC CLUTTER-CANCELER FOR MICROWAVE LIFE-DETECTION SYSTEMS [J].
CHUANG, HR ;
CHEN, YF ;
CHEN, KM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) :747-750
[10]  
Das V., 2012, 2012 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), P13, DOI 10.1109/BioWireless.2012.6172730