Fast gas chromatography negative chemical ionization tandem mass spectrometry of explosive compounds using dynamic collision-induced dissociation

被引:25
作者
Collin, Olivier L. [1 ]
Zimmermann, Carolyn M. [1 ]
Jackson, Glen P. [1 ]
机构
[1] Ohio Univ, Clippinger Labs, Dept Chem & Biochem, Ctr Intelligent Chem Instrumentat, Athens, OH 45701 USA
基金
美国国家科学基金会;
关键词
Tandem mass spectrometry; Dynamic collision-induced dissociation (DCID); Gas chromatography; Explosive; QUADRUPOLE ION-TRAP; ELECTRON-CAPTURE DETECTION; LOW PICOGRAM LEVEL; LIQUID-CHROMATOGRAPHY; PUBLIC PLACES; SCAN; FRAGMENTATION; TRACES; WATER;
D O I
10.1016/j.ijms.2008.10.009
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The analysis of nine explosive compounds by gas chromatography tandem mass spectrometry (GC-MS/MS) using negative chemical ionization (NCI) was performed under two different conditions: first, a conventional GC separation Coupled with a standard ion dissociation method in a quadrupole ion trap (QIT) was performed in segmented selected reaction monitoring mode; second, a fast GC separation on a microbore capillary column was combined with a faster method of collisional activation in ion traps wherein fragmentation is deliberately accomplished during the mass acquisition scan. The conventional GC-MS/MS method provided separation times in 10 min with detection limits between 0.8 and 280 pg on column. The fast GC method with dynamic collision-induced dissociation (DCID) offered a confirmatory method for the analysis of high explosives with separation times under 2.5 min and detection limits between 0.5 and 5 pg on column, without any hardware modifications to the instrument. The implementation of DCID in combination with three-times-faster mass scanning allows the acquisition of tandem mass spectra to at least 5 Hz (while averaging three scans per spectrum). Although detection limits for GC-NCI-MS/MS using conventional CID or DCID are not quite on par with LODs achieved by GC-ECD, the combination of NCI with DCID tandem MS leads to detection limits at least comparable, if not superior, to other mass spectrometric methods. Selected reaction monitoring in the negative ionization mode is anticipated to offer the most selective approach to detecting explosives and eliminating potential interferences, which could ultimately lead to the best detection limits for real. contaminated samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 29 条
[2]   NEGATIVE CHEMICAL IONIZATION (NCI) OF ORGANIC-COMPOUNDS [J].
BUDZIKIEWICZ, H .
MASS SPECTROMETRY REVIEWS, 1986, 5 (04) :345-380
[3]   ELECTRON-CAPTURE TECHNIQUE SPECIFIC FOR EXPLOSIVES DETECTION [J].
CLINE, JE ;
HOBBS, JR ;
BARRINGTON, AE .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1974, 7 (12) :965-966
[4]   Dynamic collision-induced dissociation of peptides in a quadrupole ion trap mass spectrometer [J].
Collin, Olivier L. ;
Beier, Matthias ;
Jackson, Glen P. .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5468-5473
[5]   Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector [J].
Collin, Olivier L. ;
Niegel, Claudia ;
DeRhodes, Kate E. ;
McCord, Bruce R. ;
Jackson, Glen P. .
JOURNAL OF FORENSIC SCIENCES, 2006, 51 (04) :815-818
[6]  
Crowson CA, 1996, J FORENSIC SCI, V41, P980
[7]  
Cullum HE, 2004, J FORENSIC SCI, V49, P684
[8]   TRACE ANALYSIS OF EXPLOSIVES AT THE LOW PICOGRAM LEVEL USING SILICA CAPILLARY COLUMN GAS-CHROMATOGRAPHY WITH THERMAL-ENERGY ANALYZER DETECTION [J].
DOUSE, JMF .
JOURNAL OF CHROMATOGRAPHY, 1983, 256 (02) :359-362
[9]   TRACE ANALYSIS OF EXPLOSIVES AT THE LOW PICOGRAM LEVEL BY SILICA CAPILLARY COLUMN GAS-LIQUID-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
DOUSE, JMF .
JOURNAL OF CHROMATOGRAPHY, 1981, 208 (01) :83-88
[10]  
FETTEROLF DD, 1995, FORENSIC APPL MASS S, P215