Organic transistor-based chemical sensors with self-assembled monolayers

被引:10
作者
Minami, Tsuyoshi [1 ]
机构
[1] Univ Tokyo, Inst Ind Sci, Meguro Ku, 4-6-1 Komaba, Tokyo 1538505, Japan
关键词
Self-assembly; Organic transistor; Molecular recognition; Chemical sensors; FIELD-EFFECT TRANSISTOR; ELECTRICAL DETECTION; SEPTIC SHOCK; METAL-IONS; LACTATE; BINDING; NITRATE; PROTEIN; RECOGNITION; WATER;
D O I
10.1007/s10847-021-01050-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Numerous artificial receptors with noncovalent bonds have been developed to date, whereas chemical sensing devices combined with these receptors have not been fully established. An organic thin-film transistor (OTFT) can potentially operate as a supramolecular sensor chip by appropriately combining it with molecular recognition parts. In this review, the attempts to fabricate devices for electrical chemical sensing utilizing a self-assembled monolayer on a gate electrode or a surface of a semiconductor layer of the OTFT are described. Self-assembled scaffolds provide multi-recognition sites, leading to selective and sensitive detection. Furthermore, the OTFT functionalized with various receptors provide comprehensive sensor platforms for multiple analytes including cations, anions, electrically neutral molecules, and proteins in aqueous media. The OTFT-based sensor successfully detected analytes with size and chemical structural dependences on self-assembled receptors. Moreover, real-time continuous detection was also accomplished by the OTFT-based sensor integrated with a microfluidic system. Thus, this concept implies a promising future for applying an easy-to-use chemical sensor in practical situations by taking advantage of well-developed supramolecular interactions.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 110 条
[41]   Crystalline Ultrasmooth Self-Assembled Monolayers of Alkylsilanes for Organic Field-Effect Transistors [J].
Ito, Yutaka ;
Virkar, Ajay A. ;
Mannsfeld, Stefan ;
Oh, Joon Hak ;
Toney, Michael ;
Locklin, Jason ;
Bao, Zhenan .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (26) :9396-9404
[42]   Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis [J].
James, JH ;
Luchette, FA ;
McCarter, FD ;
Fischer, JE .
LANCET, 1999, 354 (9177) :505-508
[43]   Heteroarenes as high performance organic semiconductors [J].
Jiang, Wei ;
Li, Yan ;
Wang, Zhaohui .
CHEMICAL SOCIETY REVIEWS, 2013, 42 (14) :6113-6127
[44]   Receptors for tetrahedral oxyranions [J].
Katayev, Evgeny A. ;
Ustynyuk, Yuri A. ;
Sessler, Jonathan L. .
COORDINATION CHEMISTRY REVIEWS, 2006, 250 (23-24) :3004-3037
[45]   A Water-Gate Organic Field-Effect Transistor [J].
Kergoat, Loig ;
Herlogsson, Lars ;
Braga, Daniele ;
Piro, Benoit ;
Pham, Minh-Chau ;
Crispin, Xavier ;
Berggren, Magnus ;
Horowitz, Gilles .
ADVANCED MATERIALS, 2010, 22 (23) :2565-2569
[46]   Double-hexahistidine tag with high-affinity binding for protein immobilization, purification, and detection on Ni-nitrilotriacetic acid surfaces [J].
Khan, Farid ;
He, Mingyue ;
Taussig, Michael J. .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3072-3079
[47]   Microfabricated electrochemical nitrate sensor using double-potential-step chronocoulometry [J].
Kim, Dohyun ;
Goldberg, Ira B. ;
Judy, Jack W. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 135 (02) :618-624
[48]   Ultralow-power organic complementary circuits [J].
Klauk, Hagen ;
Zschieschang, Ute ;
Pflaum, Jens ;
Halik, Marcus .
NATURE, 2007, 445 (7129) :745-748
[49]   Solvent Effect on the Fluorescence Response of Hydroxycoumarin Bearing a Dipicolylamine Binding Site to Metal Ions [J].
Kobayashi, Hiroyuki ;
Katano, Kohei ;
Hashimoto, Takeshi ;
Hayashita, Takashi .
ANALYTICAL SCIENCES, 2014, 30 (11) :1045-1050
[50]   SIGNIFICANCE OF BLOOD LACTATE LEVELS IN CRITICALLY ILL PATIENTS WITH LIVER-DISEASE [J].
KRUSE, JA ;
ZAIDI, SAJ ;
CARLSON, RW .
AMERICAN JOURNAL OF MEDICINE, 1987, 83 (01) :77-82