An Innovative Wearable Device For Monitoring Continuous Body Surface Temperature (HEARThermo): Instrument Validation Study

被引:4
作者
Yeh, Chun-Yin [1 ,2 ]
Chung, Yi-Ting [2 ]
Chuang, Kun-Ta [1 ]
Shu, Yu-Chen [3 ]
Kao, Hung-Yu [1 ]
Chen, Po-Lin [4 ,5 ,6 ]
Ko, Wen-Chien [4 ,6 ]
Ko, Nai-Ying [2 ,7 ]
机构
[1] Natl Cheng Kung Univ, Dept Comp Sci & Informat Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Dept Nursing, 1,Univ Rd, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ, Dept Math, Tainan, Taiwan
[4] Natl Cheng Kung Univ, Dept Med, Tainan, Taiwan
[5] Natl Cheng Kung Univ, Dept Microbiol & Immunol, Tainan, Taiwan
[6] Natl Cheng Kung Univ Hosp, Dept Internal Med, Tainan, Taiwan
[7] Natl Cheng Kung Univ, Dept Publ Hlth, Tainan, Taiwan
来源
JMIR MHEALTH AND UHEALTH | 2021年 / 9卷 / 02期
关键词
CRITICALLY-ILL PATIENTS; CURVE COMPLEXITY; SEPSIS; ABNORMALITIES; THERMOMETERS; MANAGEMENT; DIAGNOSIS; SURVIVAL; VALIDITY; IMPACT;
D O I
10.2196/19210
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Variations in body temperature are highly informative during an illness. To date, there are not many adequate studies that have investigated the feasibility of a wearable wrist device for the continuous monitoring of body surface temperatures in humans. Objective: The objective of this study was to validate the performance of HEARThermo, an innovative wearable device, which was developed to continuously monitor the body surface temperature in humans. Methods: We implemented a multi-method research design in this study, which included 2 validation studies-one in the laboratory and one with human subjects. In validation study I, we evaluated the test-retest reliability of HEARThermo in the laboratory to measure the temperature and to correct the values recorded by each HEARThermo by using linear regression models. We conducted validation study II on human subjects who wore HEARThermo for the measurement of their body surface temperatures. Additionally, we compared the HEARThermo temperature recordings with those recorded by the infrared skin thermometer simultaneously. We used intraclass correlation coefficients (ICCs) and Bland-Altman plots to analyze the criterion validity and agreement between the 2 measurement tools. Results: A total of 66 participants (age range, 10-77 years) were recruited, and 152,881 completed data were analyzed in this study. The 2 validation studies in the laboratory and on human skin indicated that HEARThermo showed a good test-retest reliability (ICC 0.96-0.98) and adequate criterion validity with the infrared skin thermometer at room temperatures of 20 degrees C-27.9 degrees C (ICC 0.72, P <.001). The corrected measurement bias averaged -0.02 degrees C, which was calibrated using a water bath ranging in temperature from 16 degrees C to 40 degrees C. The values of each HEARThermo improved by the regression models were not significantly different from the temperature of the water bath (P=.19). Bland-Altman plots showed no visualized systematic bias. HEARThermo had a bias of 1.51 degrees C with a 95% limit of agreement between -1.34 degrees C and 4.35 degrees C. Conclusions: The findings of our study show the validation of HEARThermo for the continuous monitoring of body surface temperatures in humans.
引用
收藏
页数:10
相关论文
共 42 条
  • [11] Three types of skin-surface thermometers - A comparison of reliability, validity, and responsiveness
    Burnham, RS
    McKinley, RS
    Vincent, DD
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2006, 85 (07) : 553 - 558
  • [12] Investigation of human body skin temperatures as a bio-signal to indicate overall thermal sensations
    Choi, Joon-Ho
    Loftness, Vivian
    [J]. BUILDING AND ENVIRONMENT, 2012, 58 : 258 - 269
  • [13] Predicting survival in critical patients by use of body temperature regularity measurement based on approximate entropy
    Cuesta, D.
    Varela, M.
    Miro, P.
    Galdos, P.
    Abasolo, D.
    Hornero, R.
    Aboy, M.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (07) : 671 - 678
  • [14] Wearable Health Devices-Vital Sign Monitoring, Systems and Technologies
    Dias, Duarte
    Silva Cunha, Joao Paulo
    [J]. SENSORS, 2018, 18 (08)
  • [15] The impact of continuous versus intermittent vital signs monitoring in hospitals: A systematic review and narrative synthesis
    Downey, C. L.
    Chapman, S.
    Randell, R.
    Brown, J. M.
    Jayne, D. G.
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2018, 84 : 19 - 27
  • [16] Body temperature patterns as a predictor of hospital-acquired sepsis in afebrile adult intensive care unit patients: a case-control study
    Drewry, Anne M.
    Fuller, Brian M.
    Bailey, Thomas C.
    Hotchkiss, Richard S.
    [J]. CRITICAL CARE, 2013, 17 (05)
  • [17] Elitech, 2016, RC 4 INSTR
  • [18] Diagnosis and management of pneumonia and bronchitis in outpatient primary care practices
    Evertsen, Jennifer
    Baumgardner, Dennis J.
    Regnery, Ann
    Banerjee, Indrani
    [J]. PRIMARY CARE RESPIRATORY JOURNAL, 2010, 19 (03): : 237 - 241
  • [19] Physiological monitoring for critically ill patients: Testing a predictive model for the early detection of sepsis
    Giuliano, Karen K.
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2007, 16 (02) : 122 - 130
  • [20] Wearable Sensors Reveal Menses-Driven Changes in Physiology and Enable Prediction of the Fertile Window: Observational Study
    Goodale, Brianna Mae
    Shilaih, Mohaned
    Falco, Lisa
    Dammeier, Franziska
    Hamvas, Gyorgyi
    Leeners, Brigitte
    [J]. JOURNAL OF MEDICAL INTERNET RESEARCH, 2019, 21 (04)