An Innovative Wearable Device For Monitoring Continuous Body Surface Temperature (HEARThermo): Instrument Validation Study

被引:4
作者
Yeh, Chun-Yin [1 ,2 ]
Chung, Yi-Ting [2 ]
Chuang, Kun-Ta [1 ]
Shu, Yu-Chen [3 ]
Kao, Hung-Yu [1 ]
Chen, Po-Lin [4 ,5 ,6 ]
Ko, Wen-Chien [4 ,6 ]
Ko, Nai-Ying [2 ,7 ]
机构
[1] Natl Cheng Kung Univ, Dept Comp Sci & Informat Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Dept Nursing, 1,Univ Rd, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ, Dept Math, Tainan, Taiwan
[4] Natl Cheng Kung Univ, Dept Med, Tainan, Taiwan
[5] Natl Cheng Kung Univ, Dept Microbiol & Immunol, Tainan, Taiwan
[6] Natl Cheng Kung Univ Hosp, Dept Internal Med, Tainan, Taiwan
[7] Natl Cheng Kung Univ, Dept Publ Hlth, Tainan, Taiwan
来源
JMIR MHEALTH AND UHEALTH | 2021年 / 9卷 / 02期
关键词
CRITICALLY-ILL PATIENTS; CURVE COMPLEXITY; SEPSIS; ABNORMALITIES; THERMOMETERS; MANAGEMENT; DIAGNOSIS; SURVIVAL; VALIDITY; IMPACT;
D O I
10.2196/19210
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Variations in body temperature are highly informative during an illness. To date, there are not many adequate studies that have investigated the feasibility of a wearable wrist device for the continuous monitoring of body surface temperatures in humans. Objective: The objective of this study was to validate the performance of HEARThermo, an innovative wearable device, which was developed to continuously monitor the body surface temperature in humans. Methods: We implemented a multi-method research design in this study, which included 2 validation studies-one in the laboratory and one with human subjects. In validation study I, we evaluated the test-retest reliability of HEARThermo in the laboratory to measure the temperature and to correct the values recorded by each HEARThermo by using linear regression models. We conducted validation study II on human subjects who wore HEARThermo for the measurement of their body surface temperatures. Additionally, we compared the HEARThermo temperature recordings with those recorded by the infrared skin thermometer simultaneously. We used intraclass correlation coefficients (ICCs) and Bland-Altman plots to analyze the criterion validity and agreement between the 2 measurement tools. Results: A total of 66 participants (age range, 10-77 years) were recruited, and 152,881 completed data were analyzed in this study. The 2 validation studies in the laboratory and on human skin indicated that HEARThermo showed a good test-retest reliability (ICC 0.96-0.98) and adequate criterion validity with the infrared skin thermometer at room temperatures of 20 degrees C-27.9 degrees C (ICC 0.72, P <.001). The corrected measurement bias averaged -0.02 degrees C, which was calibrated using a water bath ranging in temperature from 16 degrees C to 40 degrees C. The values of each HEARThermo improved by the regression models were not significantly different from the temperature of the water bath (P=.19). Bland-Altman plots showed no visualized systematic bias. HEARThermo had a bias of 1.51 degrees C with a 95% limit of agreement between -1.34 degrees C and 4.35 degrees C. Conclusions: The findings of our study show the validation of HEARThermo for the continuous monitoring of body surface temperatures in humans.
引用
收藏
页数:10
相关论文
共 42 条
  • [1] Features and application of wearable biosensors in medical care
    Ajami, Sima
    Teimouri, Fotooheh
    [J]. JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2015, 20 (12): : 1208 - 1215
  • [2] [Anonymous], 2014, BEURER INFRARED FORE
  • [3] [Anonymous], 2018, PEDIATR NURS
  • [4] [Anonymous], 2017, GM 108 DRAV
  • [5] [Anonymous], 2007, 15043 CNS
  • [6] [Anonymous], 2007, 15042 CNS
  • [7] Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges
    Banaee, Hadi
    Ahmed, Mobyen Uddin
    Loutfi, Amy
    [J]. SENSORS, 2013, 13 (12) : 17472 - 17500
  • [8] EMERGENCY NURSING RESOURCE: NON-INVASIVE TEMPERATURE MEASUREMENT IN THE EMERGENCY DEPARTMENT
    Barnason, Susan
    Williams, Jennifer
    Proehl, Jean
    Brim, Carla
    Crowley, Melanie
    Leviner, Sherry
    Lindauer, Cathleen
    Naccarato, Mary
    Storer, Andrew
    [J]. JOURNAL OF EMERGENCY NURSING, 2012, 38 (06) : 523 - 530
  • [9] Infrared camera assessment of skin surface temperature - Effect of emissivity
    Bernard, V.
    Staffa, E.
    Mornstein, V.
    Bourek, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (06): : 583 - 591
  • [10] Variability Analysis and the Diagnosis, Management, and Treatment of Sepsis
    Buchan, C. Arianne
    Bravi, Andrea
    Seely, Andrew J. E.
    [J]. CURRENT INFECTIOUS DISEASE REPORTS, 2012, 14 (05) : 512 - 521