Design and performance of the SLD vertex detector: a 307 Mpixel tracking system

被引:103
作者
Abe, K
Arodzero, A
Baltay, C
Brau, JE
Breidenbach, M
Burrows, PN
Chou, AS
Crawford, G
Damerell, CJS
Dervan, PJ
Dong, DN
Emmet, W
English, RL
Etzion, E
Foss, M
Frey, R
Haller, G
Hasuko, K
Hertzbach, SS
Hoeflich, J
Huffer, ME
Jackson, DJ
Jaros, JA
Kelsey, J
Lee, I
Lia, V
Lintern, AL
Liu, MX
Manly, SL
Masuda, H
McKemey, AK
Moore, TB
Nichols, A
Nagamine, T
Oishi, N
Osborne, LS
Russell, JJ
Ross, D
Serbo, VV
Sinev, NB
Sinnott, J
Skarpaas, K
Smy, MB
Snyder, JA
Strauss, MG
Dong, S
Suekane, F
Taylor, FE
Trandafir, AI
Usher, T
机构
[1] RUTHERFORD APPLETON LAB,DIDCOT OX11 0QX,OXON,ENGLAND
[2] TOHOKU UNIV,SENDAI,MIYAGI 98077,JAPAN
[3] UNIV OREGON,EUGENE,OR 97403
[4] YALE UNIV,NEW HAVEN,CT 06511
[5] STANFORD LINEAR ACCELERATOR CTR,STANFORD,CA 94309
[6] MIT,CAMBRIDGE,MA 02139
[7] BRUNEL UNIV,UXBRIDGE UB8 3PM,MIDDX,ENGLAND
[8] UNIV MASSACHUSETTS,AMHERST,MA 01003
[9] NAGOYA UNIV,NAGOYA,AICHI 464,JAPAN
[10] UNIV WISCONSIN,MADISON,WI 53706
[11] COLORADO STATE UNIV,FT COLLINS,CO 80523
[12] UNIV WASHINGTON,SEATTLE,WA 98195
基金
美国国家科学基金会;
关键词
vertex detector; particle tracking; pixels; charge-coupled device (CCD) heavy flavour; charm quark; bottom quark; tau lepton;
D O I
10.1016/S0168-9002(97)01011-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the design, construction, and initial operation of SLD's upgraded vertex detector which comprises 96 two-dimensional charge-coupled devices (CCDs) with a total of 307 Mpixel. Each pixel functions as an independent particle detecting element, providing space point measurements of charged particle tracks with a typical precision of 4 mu m in each co-ordinate. The CCDs are arranged in three concentric cylinders just outside the beam-pipe which surrounds the e(+)e(-) collision point of the SLAG Linear Collider (SLC). The detector is a powerful tool for distinguishing displaced vertex tracks, produced by decay inflight of heavy flavour hadrons or tau leptons, from tracks produced at the primary event vertex. The requirements for this detector include a very low mass structure (to minimize multiple scattering) both for mechanical support and to provide signal paths for the CCDs; operation at love temperature with a high degree of mechanical. stability: and high speed CCD readout, signal processing, and data sparsification. The lessons learned in achieving these goals should be useful for the construction of large arrays of CCDs or active pixel devices in the future in a number of areas of science and technology.
引用
收藏
页码:287 / 343
页数:57
相关论文
共 27 条
  • [1] AGNEW GD, 1992, P 26 INT C HIGH EN P, V2, P1862
  • [2] 1ST MEASUREMENT OF EFFICIENCY AND PRECISION OF CCD DETECTORS FOR HIGH-ENERGY PHYSICS
    BAILEY, R
    DAMERELL, CJS
    ENGLISH, RL
    GILLMAN, AR
    LINTERN, AL
    WATTS, SJ
    WICKENS, FJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (2-3): : 201 - 215
  • [3] MEASUREMENT OF THE LIFETIME OF THE CHARMED BARYON LAMBDA-C
    BARLAG, S
    BECKER, H
    BOHRINGER, T
    BOSMAN, M
    CASTILLO, V
    CHABAUD, V
    DAMERELL, C
    DAUM, C
    DIETL, H
    GILLMAN, A
    GILMORE, R
    GOOCH, T
    GORLICH, L
    GRAS, P
    HAJDUK, Z
    HIGON, E
    KELSEY, DP
    KLANNER, R
    KWAN, S
    LUCKING, B
    LUTJENS, G
    LUTH, V
    LUTZ, G
    MALOS, J
    MANNER, W
    NEUGEBAUER, E
    PALKA, H
    PEPE, M
    RICHARDSON, J
    RYBICKI, K
    SEEBRUNNER, HJ
    STIERLIN, U
    TIECKE, HG
    WALTERMANN, G
    WATTS, S
    WEILHAMMER, P
    WICKENS, F
    WIGGERS, LW
    ZELUDZIEWICZ, T
    [J]. PHYSICS LETTERS B, 1987, 184 (2-3) : 283 - 287
  • [5] CHARGE COUPLED SEMICONDUCTOR DEVICES
    BOYLE, WS
    SMITH, GE
    [J]. BELL SYSTEM TECHNICAL JOURNAL, 1970, 49 (04): : 587 - +
  • [6] *CERN PROGR LIB CE, 1996, GEANT 3 21 PROGR
  • [7] Damerell C, 1995, RALP95008
  • [8] REAL-TIME DATA SPARSIFICATION FOR THE SLD VERTEX DETECTOR
    DAMERELL, CJS
    GILLMAN, AR
    PHILLIPS, DA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 305 - 309
  • [9] CHARGE-COUPLED-DEVICES FOR PARTICLE-DETECTION WITH HIGH SPATIAL-RESOLUTION
    DAMERELL, CJS
    FARLEY, FJM
    GILLMAN, AR
    WICKENS, FJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 33 - 42
  • [10] USE OF CHARGE-COUPLED-DEVICES AS HIGH-PRECISION DETECTORS
    DAMERELL, CJS
    ENGLISH, RL
    GILLMAN, AR
    LINTERN, AL
    WICKENS, FJ
    WATTS, SJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 51 - 53