Fatigue behavior of bonded lithium disilicate glass-ceramic simplified restorations is not damaged by the finishing/grinding of the bonding surface of dentin analogue material

被引:2
作者
Cadore-Rodrigues, Ana Carolina [1 ]
Machry, Renan Vaz [1 ]
de Lima Burgo, Thiago Augusto [2 ]
Venturini, Andressa Borin [1 ]
May, Liliana Gressler [1 ]
Valandro, Luiz Felipe [1 ]
机构
[1] Univ Fed Santa Maria, Postgrad Program Oral Sci, 1000 Roraima Av,T St,Bldg 26F,Room 2386, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, Phys Dept, Postgrad Program Phys, 1000 Roraima Av,T St,Bldg 13,Room 1123, BR-97105900 Santa Maria, RS, Brazil
关键词
Dental finishing; B; Ceramics; Epoxy resin; C; Fatigue;
D O I
10.1016/j.ijadhadh.2021.102824
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fiber-reinforced epoxy resin has been utilized as dentin-analogue material in fatigue tests, owing to their similar resin adhesion and biomechanical behavior. The procedures for finishing the dental surface change the surface topography, promoting variable roughness in the prepared substrate, which influences the interaction between the resin cement and the bonding surface. This study evaluated the influence of finishing by grinding the bonding surface of dentin analogue material (epoxy resin) on the fatigue behavior of adhesively cemented lithium disilicate glass-ceramic simplified restorations. Epoxy resin discs (0 = 10 mm, thickness = 2 mm) were allocated into four groups considering the ?grinding? factor: CTRL ? no grinding; G ? grinding with coarse grit diamond bur; G + F ? grinding with coarse grit diamond bur followed by fine grit diamond bur; G + F + FF ? grinding with coarse grit diamond bur followed by fine and extra fine grit diamond burs. After grinding, the discs were cleaned, etched (10% hydrofluoric acid; 1 min) and received a primer coating. Lithium disilicate discs (0 = 10 mm, thickness = 1 mm) were also etched (5% hydrofluoric acid; 20 s) and received a silane agent, and then were adhesively cemented onto epoxy resin discs and subjected to a step-stress fatigue tests at 20 Hz, 10,000 cycles/ step with a step-size of 100 N. Fractography, surface topography, roughness and fractal dimension analyses were performed. The CTRL group showed the lowest fatigue performance, roughness and surface area values. No statistical difference for fatigue performance and surface area was observed among the ?grinding? groups, having a decreasing roughness relationship (G > G + F > G + F + FF). Therefore, the grinding the preparation surface with distinct diamond bur sequence has no effect on the fatigue behavior of lithium disilicate restorations, as well as, grinding promotes improved results over a non-ground surface. Thus, it is important to pay attention to managing the dentin analogue surface considering that the epoxy resin with unground surfaces induces lower fatigue behavior.
引用
收藏
页数:7
相关论文
共 20 条
  • [1] Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    Attia, A
    Abdelaziz, KM
    Freitag, S
    Kern, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) : 117 - 123
  • [2] Influence of tooth surface roughness and type of cement on retention of complete cast crowns
    Ayad, MF
    Rosenstiel, SF
    Salama, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (02) : 116 - 121
  • [3] Effect of surface treatment on roughness and bond strength of a heat-pressed ceramic
    Ayad, Mohamed F.
    Fahmy, Nadia Z.
    Rosenstiel, Stephen F.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02) : 123 - 130
  • [4] The contact mechanics of fractal surfaces
    Buzio, R
    Boragno, C
    Biscarini, F
    De Mongeot, FB
    Valbusa, U
    [J]. NATURE MATERIALS, 2003, 2 (04) : 233 - 236
  • [5] The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses
    Chen, Chenfeng
    Trindade, Flavia Zardo
    de Jager, Niek
    Kleverlaan, Cornelis J.
    Feilzer, Albert J.
    [J]. DENTAL MATERIALS, 2014, 30 (09) : 954 - 962
  • [6] The effect of internal roughness and bonding on the fracture resistance and structural reliability of lithium disilicate ceramic
    de Kol, Paul
    Pereira, Gabriel K. R.
    Fraga, Sara
    de Jager, Niek
    Venturini, Andressa B.
    Kleverlaan, Cornelis J.
    [J]. DENTAL MATERIALS, 2017, 33 (12) : 1416 - 1425
  • [7] THE EFFECT OF SURFACE-ROUGHNESS OF CROWN PREPARATIONS ON RETENTION OF CEMENTED CASTINGS
    FELTON, DA
    KANOY, BE
    WHITE, JT
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1987, 58 (03) : 292 - 296
  • [8] Gonzaga C.C., 2015, J INT SCH RES NOTICE, V2015, P1
  • [9] Griffith A. A., 1921, Philos. Trans. R. Soc., V221, P582, DOI DOI 10.1098/RSTA.1921.0006
  • [10] Fatigue Failure Load of a Bonded Simplified Monolithic Feldspathic Ceramic: Influence of Hydrofluoric Acid Etching and Thermocycling
    Guilardi, L. F.
    Pereira, G. K. R.
    Vallau, A. S.
    Silva, I. A.
    Giordani, J. C.
    Valandro, L. F.
    Rippe, M. P.