Isolation of tumor cells using size and deformation

被引:191
作者
Mohamed, Hisham [1 ]
Murray, Megan [1 ]
Turner, James N. [1 ,2 ]
Caggana, Michele [1 ,2 ]
机构
[1] New York State Dept Hlth, Wadsworth Ctr, Albany, NY 12201 USA
[2] SUNY Albany, Dept Biomed Sci, Albany, NY 12201 USA
基金
美国国家科学基金会;
关键词
Biochips; Cell sorting; Cancer; Rare cells; POLYMERASE-CHAIN-REACTION; BREAST-CANCER; CAM OVEREXPRESSION; MEMBRANE ANTIGEN; BLOOD; SEPARATION; MICROMETASTASES; EXPRESSION; LEUKOCYTES; SURVIVAL;
D O I
10.1016/j.chroma.2009.05.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The isolation and analysis of circulating tumor cells (CTCs) from blood are the Subject of intense research. Although tests to detect metastasis on a molecular level are available, progress has been hampered by a lack of tumor-specific markers and predictable DNA abnormalities. The main challenge in this endeavor is the small number of available cells of interest, 1-2 per mL in whole blood. We have designed a micro-machined device to fractionate whole blood using physical means to enrich for and/or isolate rare cells from peripheral circulation. It has arrays of four successively narrower channels, each consisting of a two-dimensional array of columns. Current devices have channels ranging in width from 20 to 5 mu m, and in depth from 20 to 5 mu m. Several optimizations resulting in the fabrication of a total of 10 derivative devices have been carried out; only two types are used in this study. Both have increasingly narrower gap widths between the columns along the flow axis with 20, 15, 10, and 5 mu m spacing all on one device. The first 20 mu m wide segment disperses the cell suspension and creates an evenly distributed flow over the entire device, whereas the others were designed to retain increasingly smaller cells. The channel depth is constant across the entire device, the first type was 10 mu m deep and the second type is 20 mu m deep. When cells from each of eight tumor cell lines were loaded into the device, all cancerous cells were isolated. In mixing experiments using human whole blood, we were able to fractionate cancer cells without interference from the blood cells. Additionally, either intact cells, or DNA, could be extracted for molecular analysis. The ultimate goal of this work is to characterize the cells oil the molecular level to provide non-invasive methods to monitor patients, stage disease, and assess treatment efficacy. Furthermore, this work Will use gene expression profiles to gain insights into metastasis. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:8289 / 8295
页数:7
相关论文
共 34 条
[1]  
[Anonymous], 1869, The Australian Medical Journal
[2]   Microfluidic sorting system based on optical waveguide integration and diode laser bar trapping [J].
Applegate, RW ;
Squier, J ;
Vestad, T ;
Oakey, J ;
Marr, DWM ;
Bado, P ;
Dugan, MA ;
Said, AA .
LAB ON A CHIP, 2006, 6 (03) :422-426
[3]  
Berger M, 2001, ELECTROPHORESIS, V22, P3883, DOI 10.1002/1522-2683(200110)22:18<3883::AID-ELPS3883>3.0.CO
[4]  
2-4
[5]   Circulating Tumor Cells in Solid Cancer: Tumor Marker of Clinical Relevance? [J].
Bertazza, Loris ;
Mocellin, Simone ;
Nitti, Donato .
CURRENT ONCOLOGY REPORTS, 2008, 10 (02) :137-146
[6]  
BOYUM A, 1974, TISSUE ANTIGENS, V4, P269
[7]   Recent advances in technologies for the detection of occult metastatic cells in bone marrow of breast cancer patients [J].
Braun, S ;
Harbeck, N .
BREAST CANCER RESEARCH, 2001, 3 (05) :285-288
[8]   Microfluidic Cell Separation by 2-dimensional Dielectrophoresis [J].
De Gasperis G. ;
Yang J. ;
Becker F.F. ;
Gascoyne P.R.C. ;
Wang X.-B. .
Biomedical Microdevices, 1999, 2 (1) :41-49
[9]   HETEROGENOUS EXPRESSION OF CELL-SURFACE ANTIGENS IN NORMAL EPITHELIA AND THEIR TUMORS, REVEALED BY MONOCLONAL-ANTIBODIES [J].
EDWARDS, PAW .
BRITISH JOURNAL OF CANCER, 1985, 51 (02) :149-160
[10]   Dielectrophoretic separation of cancer cells from blood [J].
Gascoyne, PRC ;
Wang, XB ;
Huang, Y ;
Becker, FF .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :670-678