Measurement of cystatin C in capillary blood samples in pediatric patients

被引:3
|
作者
van Deutekom, Arend W. [1 ]
Zur, Berndt [2 ]
van Wijk, Joanna A. E. [1 ]
Bouman, Anna A. [3 ]
Bokenkamp, Arend [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Pediat, NL-1081 HV Amsterdam, Netherlands
[2] Univ Bonn, Med Ctr, Inst Clin Chem & Pharmacol, D-5300 Bonn, Germany
[3] Vrije Univ Amsterdam, Med Ctr, Dept Clin Chem, NL-1081 HV Amsterdam, Netherlands
关键词
Cystatin-C; Capillary blood samples; Children; GLOMERULAR-FILTRATION-RATE; BETA-TRACE-PROTEIN; SERUM CREATININE; CHILDREN;
D O I
10.1016/j.clinbiochem.2009.09.021
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We assessed whether the GFR marker cystatin C can be measured reliably in capillary blood samples in children with renal disease. Cystatin C was measured in venous and capillary blood samples obtained simultaneously from 48 children, and GFR was estimated using the Filler equation. Estimated GFR based on capillary cystatin C concentrations was higher than the venous cystatin C based GFR. The limits of agreement between estimated GFR based on capillary and venous measurements exceeded +/-20% at the Upper reference concentration, which hampers the clinical usefulness of capillary sampling. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [1] Measurement of cystatin C, beta- trace protein and microglobulin in capillary blood samples
    van Deutekom, A. W.
    Zur, B.
    van Wijk, J. A. E.
    Bouman, A. A.
    Bokenkamp, A.
    PEDIATRIC NEPHROLOGY, 2009, 24 (04) : 915 - 915
  • [2] Cystatin C can be measured reliably in capillary blood samples
    Kort, SAR
    Bouman, AA
    Blankenstein, MA
    Bökenkamp, A
    CLINICA CHIMICA ACTA, 2005, 355 : S404 - S405
  • [3] Cystatin C can be measured reliably in capillary blood samples
    Kort, SAR
    Bouman, AA
    Blankenstein, MA
    Bökenkamp, A
    CLINICAL CHEMISTRY, 2005, 51 (05) : 903 - 904
  • [4] Measurement of cystatin C in elderly patients with heart failure
    Mendez Bailon, Manuel
    Romero Roman, Carlos
    Conthe Gutierrez, Pedro
    Audibert Mena, Luis
    MEDICINA CLINICA, 2006, 127 (16): : 636 - 636
  • [5] Cystatin C as a marker for glomerular filtration rate in pediatric patients
    Ylinen, EA
    Ala-Houhala, M
    Harmoinen, APT
    Knip, M
    PEDIATRIC NEPHROLOGY, 1999, 13 (06) : 506 - 509
  • [6] Cystatin C should be measured in pediatric renal transplant patients!
    Filler, G
    Pham-Huy, A
    PEDIATRIC TRANSPLANTATION, 2002, 6 (05) : 357 - 360
  • [7] Cystatin C as a marker for glomerular filtration rate in pediatric patients
    Elisa A. Ylinen
    Marja Ala-Houhala
    A. P. T. Harmoinen
    Mikael Knip
    Pediatric Nephrology, 1999, 13 : 506 - 509
  • [8] ELECTRONIC PLATELET COUNTING WITH CAPILLARY BLOOD SAMPLES EXPERIENCES IN A PEDIATRIC-CLINIC
    GADNER, H
    ODENWALD, E
    RIEHM, H
    HITZIG, WH
    EUROPEAN JOURNAL OF PEDIATRICS, 1978, 129 (01) : 37 - 45
  • [9] Comparison of HbA1c measurement in remotely prepared capillary versus standard venous blood samples
    Groenendijk, W.
    Griffin, T.
    Islam, N.
    Blake, L.
    O'Shea, P. M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (SUPPL 4) : 118 - 119
  • [10] CORRELATION BETWEEN VENOUS AND CAPILLARY BLOOD-SAMPLES FOR CYCLOSPORINE MONITORING IN PEDIATRIC LIVER-TRANSPLANT PATIENTS
    PROFUMO, RJ
    FOY, TM
    KANE, RE
    CLINICAL TRANSPLANTATION, 1995, 9 (05) : 424 - 426