Pin-on-disc evaluation of self-reinforced composite poly(methyl methacrylate) for total joint replacements

被引:7
作者
Peers, William J.
Wright-Charlesworth, Debra D.
Miskioglu, Ibrahim
机构
[1] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
[2] Michigan Technol Univ, Dept Mech Engn Engn Mech, Houghton, MI 49931 USA
关键词
bone cement; PMMA; acrylic; wear; wear debris; hip prosthesis;
D O I
10.1002/jbm.b.30506
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Femoral components of hip replacements are commonly anchored in the femur with bone cement or polly(methyll methacrylate) (PMMA). Wear or fracture of bone cement can lead to loosening of the femoral component, which drastically affects the success and longevity of hip replacements. Self-reinforced composite PMMA (SRC-PMMA) has been previously developed for potential use, as a precoat material for hip replacements. The composite consists of high strength fibers that have been shown to have greatly improved mechanical properties over bulk PMMA. The goal of this work was to examine SRC-PMMA for improved wear properties, as a function of processing temperature. Pin-on-disc tests were used to characterize and rank the wear rates of SRC-PMMA and PMMA. Composites made with higher processing temperatures had significantly lower wear rates than do PMMA at a significance level of p <= 0.05. The lowest wear rate was 8.2 mu g/m, at a processing temperature of 136 degrees C, compared to a wear rate for PMMA of 13.3 mu g/m. At the lowest processing temperature (105 degrees C), a wear rate higher than PMMA was found, and failure was dominated by fiber delamination. In the more completely processed samples (122 degrees C <= T <= 150 degrees C), wear rates were equivalent to or better than PMMA, and smoother and more homogenous wear was noted in wear tracks. Fatigue cracks were prominent at higher processing temperatures or when the wear pin was riding orthogonal to fibers. Wear particles were collected and examined. Wear particle diameter and aspect ratio showed no correlation to processing temperature, but were similar to particles retrieved from human tissue samples. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 44 条
[1]  
[Anonymous], 1997, ANN BOOK ASTM STAND, DOI [10.1520/F1841-97R05.2, DOI 10.1520/C0349-97]
[2]   Tribological behaviour of drawn polypropylene [J].
Bekhet, NE .
WEAR, 1999, 236 (1-2) :55-61
[3]   DEFORMATION PROCESSING OF PMMA INTO HIGH-STRENGTH FIBERS [J].
BUCKLEY, CA ;
LAUTENSCHLAGER, EP ;
GILBERT, JL .
JOURNAL OF APPLIED POLYMER SCIENCE, 1992, 44 (08) :1321-1330
[4]   Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[5]   Charnley total hip arthroplasty in patients less than fifty years old - A twenty to twenty-five-year follow-up note [J].
Callaghan, JJ ;
Forest, EE ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :704-714
[6]  
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, V111, P105
[7]   Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[8]   CEMENT STRAIN-MEASUREMENT SURROUNDING LOOSE AND WELL-FIXED FEMORAL COMPONENT STEMS [J].
CROWNINSHIELD, RD ;
TOLBERT, JR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :819-828
[9]  
DOWD JE, 1998, CLIN ORTHOP RELAT R, V355, P123
[10]   SELF-REINFORCED COMPOSITE POLY(METHYL METHACRYLATE) - STATIC AND FATIGUE PROPERTIES [J].
GILBERT, JL ;
NEY, DS ;
LAUTENSCHLAGER, EP .
BIOMATERIALS, 1995, 16 (14) :1043-1055