Sub-3 Å apoferritin structure determined with full range of phase shifts using a single position of volta phase plate

被引:10
作者
Li, Kunpeng [1 ]
Sun, Chen [1 ]
Klose, Thomas [1 ]
Irimia-Dominguez, Jose [2 ]
Vago, Frank S. [1 ]
Vidal, Ruben [2 ]
Jiang, Wen [1 ]
机构
[1] Purdue Univ, Dept Biol Sci, Markey Ctr Struct Biol, W Lafayette, IN 47906 USA
[2] Indiana Univ Sch Med, Dept Pathol & Lab Med, Indianapolis, IN 46202 USA
关键词
Cryo-EM; Volta phase plate; Phase shift; Beam tilt; Near-atomic resolution; Apoferritin; CONTRAST; FOCUS;
D O I
10.1016/j.jsb.2019.03.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Volta Phase Plate (VPP) has become an invaluable tool for cryo-EM structural determination of small protein complexes by increasing image contrast. Currently, the standard protocol of VPP usage periodically changes the VPP position to a fresh spot during data collection. Such a protocol was to target the phase shifts to a relatively narrow range (around 90) based on the observations of increased phase shifts and image blur associated with more images taken with a single VPP position. Here, we report a 2.87 angstrom resolution structure of apoferritin reconstructed from a dataset collected using only a single position of VPP. The reconstruction resolution and map density features are nearly identical to the reconstruction from the control dataset collected with periodic change of VPP positions. Further experiments have verified that similar results, including a 2.5 angstrom resolution structure, could be obtained with a full range of phase shifts, different spots of variable phase shift increasing rates, and at different ages of the VPP post-installation. Furthermore, we have found that the phase shifts at low resolutions, probably related to the finite size of the Volta spots, could not be correctly modeled by current CTF model using a constant phase shift at all frequencies. In dataset III, severe beam tilt issue was identified but could be computationally corrected with iterative refinements. The observations in this study may provide new insights into further improvement of both the efficiency and robustness of VPP, and to help turn VPP into a plug and -play device for high -resolution cryo-EM.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 23 条
[21]   Gctf: Real-time CTF determination and correction [J].
Zhang, Kai .
JOURNAL OF STRUCTURAL BIOLOGY, 2016, 193 (01) :1-12
[22]   MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy [J].
Zheng, Shawn Q. ;
Palovcak, Eugene ;
Armache, Jean-Paul ;
Verba, Kliment A. ;
Cheng, Yifan ;
Agard, David A. .
NATURE METHODS, 2017, 14 (04) :331-332
[23]  
2017, NATURE, V546, P118, DOI DOI 10.1038/NATURE22327