Comparison of Image Quality, Myocardial Perfusion, and Left Ventricular Function Between Standard Imaging and Single-Injection Ultra-Low-Dose Imaging Using a High-Efficiency SPECT Camera: The MILLISIEVERT Study

被引:79
作者
Einstein, Andrew J. [1 ,2 ,3 ]
Blankstein, Ron [4 ]
Andrews, Howard [5 ]
Fish, Mathews
Padgett, Richard [6 ]
Hayes, Sean W. [7 ,8 ,9 ,10 ]
Friedman, John D. [7 ,8 ,9 ,10 ]
Qureshi, Mehreen [1 ,2 ]
Rakotoarivelo, Harivony [1 ,2 ]
Slomka, Piotr [7 ,8 ,9 ]
Nakazato, Ryo [7 ,8 ,9 ,11 ]
Bokhari, Sabahat [1 ,2 ]
Di Carli, Marcello [4 ]
Berman, Daniel S. [7 ,8 ,9 ,10 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] New York Presbyterian Hosp, New York, NY USA
[3] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
[4] Brigham & Womens Hosp, Dept Med, Div Cardiol, Boston, MA USA
[5] Columbia Univ, Dept Biostat, New York, NY 10032 USA
[6] Oregon Heart & Vasc Inst, Springfield, OR USA
[7] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[8] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[9] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
[10] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[11] St Lukes Int Hosp, Ctr Cardiovasc, Tokyo, Japan
基金
美国国家卫生研究院;
关键词
SPECT; radiation dose reduction; high-efficiency camera; HIGH-SPEED; FREQUENCY; TL-201;
D O I
10.2967/jnumed.114.138222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SPECT myocardial perfusion imaging plays a central role in coronary artery disease diagnosis, but concerns exist regarding its radiation burden. Compared with standard Anger SPECT (A-SPECT) cameras, new high-efficiency (HE) cameras with specialized collimators and solid-state cadmium-zinc-telluride detectors offer potential to maintain image quality (IQ), while reducing administered activity and thus radiation dose to patients. No previous study has compared IQ, interpretation, total perfusion deficit (TPD), or ejection fraction (EF) in patients receiving both ultra-low-dose (ULD) imaging on an HE SPECT camera and standard low-dose (SLD) A-SPECT imaging. Methods: We compared ULD HE SPECT with SLD A-SPECT imaging by dividing the rest dose in 101 patients at 3 sites scheduled to undergo clinical A-SPECT myocardial perfusion imaging using a same day rest-stress Tc-99m protocol. Patients underwent HE SPECT imaging after an initial approximately 130-MBq (3.5 mCi) dose and SLD-A-SPECT imaging after the remainder of the planned dose. Images were scored visually by 2 masked readers for IQ and summed rest score. TPD and EF were assessed quantitatively. Results: Mean activity was 134 MBq (3.62 mCi) for ULD HE SPECT (effective dose, 1.15 mSv) and 278 MBq (7.50 mCi, 2.39 mSv) for SLD A-SPECT. Overall IQ was superior for ULD HE SPECT (P < 0.0001), with twice as many studies graded excellent quality. Extracardiac activity and overall perfusion assessment were similar. Between-method correlations were high for summed rest score (r = 0.87), TPD (r = 0.91), and EF (r = 0.88). Conclusion: ULD HE SPECT rest imaging correlates highly with SLD A-SPECT. It has improved image quality, comparable extracardiac activity, and achieves radiation dose reduction to 1 mSv for a single injection.
引用
收藏
页码:1430 / 1437
页数:8
相关论文
共 27 条
[1]   SCINTILLATION CAMERA [J].
ANGER, HO .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) :27-33
[2]  
[Anonymous], 1998, Ann ICRP, V28, P1
[3]  
[Anonymous], 2009, J RADIOLOGICAL PROTE
[4]   Stress Thallium-201/Rest Technetium-99m Sequential Dual Isotope High-Speed Myocardial Perfusion Imaging [J].
Berman, Daniel S. ;
Kang, Xingping ;
Tamarappoo, Balaji ;
Wolak, Arik ;
Hayes, Sean W. ;
Nakazato, Ryo ;
Thomson, Louise E. J. ;
Kite, Faith ;
Cohen, Ishac ;
Slomka, Piotr J. ;
Einstein, Andrew J. ;
Friedman, John D. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) :273-282
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]   Normal Stress-Only Versus Standard Stress/Rest Myocardial Perfusion Imaging Similar Patient Mortality With Reduced Radiation Exposure [J].
Chang, Su Min ;
Nabi, Faisal ;
Xu, Jiaqiong ;
Raza, Umara ;
Mahmarian, John J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) :221-230
[7]  
Cousins C., 2013, Annals of the ICRP, V42, P9, DOI 10.1016/j.icrp.2012.09.001
[8]   Patient-centered imaging [J].
DePuey, E. Gordon ;
Mahmarian, John J. ;
Miller, Todd D. ;
Einstein, Andrew J. ;
Hansen, Christopher L. ;
Holly, Thomas A. ;
Miller, Edward J. ;
Polk, Donna M. ;
Wann, L. Samuel .
JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (02) :185-215
[9]   Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera [J].
Duvall, W. Lane ;
Croft, Lori B. ;
Ginsberg, Eric S. ;
Einstein, Andrew J. ;
Guma, Krista A. ;
George, Titus ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) :847-857
[10]   The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study [J].
Duvall, W. Lane ;
Wijetunga, Melanie N. ;
Klein, Thomas M. ;
Razzouk, Louai ;
Godbold, Jim ;
Croft, Lori B. ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :370-377