Body Water Distribution and Risk of Cardiovascular Morbidity and Mortality in a Healthy Population: A Prospective Cohort Study

被引:19
作者
Knudsen, Nikoline Nygard [1 ,2 ]
Kjaerulff, Thora Majlund [1 ,2 ,5 ]
Ward, Leigh Cordwin [3 ]
Saebye, Ditte [1 ,2 ]
Holst, Claus [1 ,2 ]
Heitmann, Berit Lilienthal [1 ,2 ,4 ,5 ,6 ]
机构
[1] Bispebjerg Hosp, Inst Prevent Med, Res Unit Dietary Studies, DK-2400 Copenhagen, Denmark
[2] Frederiksberg Univ Hosp, Inst Prevent Med, Res Unit Dietary Studies, Copenhagen, Denmark
[3] Univ Queensland, Sch Chem & Mol Biosci, Brisbane, Qld, Australia
[4] Univ Sydney, Boden Inst Obes Nutr Exercise & Eating Disorders, Sydney, NSW 2006, Australia
[5] Univ Southern Denmark, Natl Inst Publ Hlth, Copenhagen, Denmark
[6] Copenhagen Univ Hosp, Res Ctr Prevent & Hlth, Glostrup, Denmark
关键词
BIOELECTRICAL-IMPEDANCE ANALYSIS; CLINICAL-PRACTICE IMPLICATIONS; PERITONEAL-DIALYSIS PATIENTS; PHASE-ANGLE; HEMODIALYSIS-PATIENTS; BIOIMPEDANCE SPECTROSCOPY; PROGNOSTIC INDICATOR; EXTRACELLULAR FLUID; HEART-FAILURE; ADULT DANES;
D O I
10.1371/journal.pone.0087466
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Early alterations in the cardiovascular structure and function may change normal body water distribution. The resulting fluid shifts may thus serve as an early marker for cardiovascular disease. However, studies examining this in healthy populations are absent. Objective: This study examined the association between the proportion of total body water that is extracellular water and subsequent development of non-fatal or fatal cardiovascular disease in a healthy population. Method: Bioelectrical impedance spectroscopy is an easy-to-use, non-invasive and relatively inexpensive technique to evaluate changes in body water distribution. A random subset (n = 2120) of Danes aged 41-71 years, examined in 1993-1994 for body water distribution by bioelectrical impedance spectroscopy was included. Cox-proportional hazard models and linear splines were performed. The ratio between resistance estimates from an infinite-frequency and from no-frequency (R-infinity/R-0) was used as a surrogate measure of ratio between extracellular water and total body water. The outcome was 13.5 years of follow-up for cardiovascular morbidity and mortality. Results: A high proportion of total body water that is extracellular water was associated with increased risk of incident cardiovascular disease. A threshold effect was evident, with greatly increased risk of cardiovascular morbidity and mortality above R-infinity/R-0 = 0.68. Below the threshold there seemed to be no additional benefit of having a low ratio. Conclusion: Our findings suggest that non-clinically evident oedema, measured as an increased proportion of total body water that is extracellular, above a threshold of 0.68, may be an early marker of pre-clinical cardiovascular disease. This simple, safe, cheap and easily obtainable measure of R-infinity/R-0 from bioelectrical impedance may help the early identification of these otherwise clinically healthy individuals who are at an increased risk of future cardiovascular disease. However, more studies are needed before it can be concluded that bioelectrical impedance spectroscopy improves clinical risk prediction.
引用
收藏
页数:7
相关论文
共 40 条
[1]   Bioelectrical impedance analysis in clinical practice: a new perspective on its use beyond body composition equations [J].
Barbosa-Silva, MCG ;
Barros, AJD .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03) :311-317
[2]   MULTIFREQUENCY BIOELECTRICAL-IMPEDANCE ESTIMATES THE DISTRIBUTION OF BODY-WATER [J].
CHA, KC ;
CHERTOW, GM ;
GONZALEZ, J ;
LAZARUS, JM ;
WILMORE, DW .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (04) :1316-1319
[3]   Water, other fluids, and fatal coronary heart disease - The Adventist Health Study [J].
Chan, J ;
Knutsen, SF ;
Blix, GG ;
Lee, JW ;
Fraser, GE .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 155 (09) :827-833
[4]   Extracellular water/intracellular water is a strong predictor of patient survival in incident peritoneal dialysis patients [J].
Chen, Wei ;
Guo, Li-Juan ;
Wang, Tao .
BLOOD PURIFICATION, 2007, 25 (03) :260-266
[5]  
Chumlea W.C., 2005, HUMAN BODY COMPOSITI, V2nd, P79
[6]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[7]   IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
CORNISH, BH ;
THOMAS, BJ ;
WARD, LC .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03) :337-346
[8]  
Danish Nephrology Register, 2011, ANN REP 2010 DAN NEP
[9]   The Danish Cancer Registry [J].
Gjerstorff, Marianne Lundkjaer .
SCANDINAVIAN JOURNAL OF PUBLIC HEALTH, 2011, 39 :42-45
[10]   Bioelectrical impedance phase angle as a prognostic indicator in advanced pancreatic cancer [J].
Gupta, D ;
Lis, CG ;
Dahlk, SL ;
Vashi, PG ;
Grutsch, JF ;
Lammersfeld, CA .
BRITISH JOURNAL OF NUTRITION, 2004, 92 (06) :957-962