Time-Efficient Fast Spin Echo Imaging at 4.7 T with Low Refocusing Angles

被引:10
作者
Lebel, R. Marc [1 ]
Wilman, Alan H. [1 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 2V2, Canada
关键词
high field; turbo spin echo; RARE; fast spin echo; 4.7; T; HUMAN BRAIN; FLIP ANGLE; IN-VIVO; MAGNETIC-FIELD; RARE-SEQUENCES; RF POWER; TRAINS; NOISE; MRI; MODULATION;
D O I
10.1002/mrm.21999
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An implementation of fast spin echo at 4.7 T designed for versatile and time-efficient T(2)-weighted imaging of the human brain is presented. Reduced refocusing angles (alpha < 180 degrees) were employed to overcome specific absorption rate (SAR) constraints and their effects on image quality assessed. Image intensity and tissue contrast variations from heterogeneous RF transmit fields and incidental magnetization transfer effects were investigated at reduced refocusing angles. We found that intraslice signal variations are minimized with refocusing angles near 180 degrees, but apparent gray/white matter contrast is independent of refocusing angle. Incidental magnetization transfer effects from multislice acquisitions were shown to attenuate white matter intensity by 25% and gray matter intensity by 15% at 180 degrees; less than 5% attenuation was seen in all tissues at flip angles below 60 degrees. We present multislice images acquired without excess delay time for SAR mitigation using a variety of protocols. Subsecond half Fourier acquisition single-shot turbo spin echo (HASTE) images were obtained with a novel variable refocusing angle echo train (20 degrees < alpha < 58 degrees) and high-resolution scans with a voxel volume of 0.18 mm(3) were acquired in 6.5 min with refocusing angles of 100 degrees. Magn Reson Med 62:96-105,2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
[41]   MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears [J].
Kowalchuk, RM ;
Kneeland, JB ;
Dalinka, MK ;
Siegelman, ES ;
Dockery, WD .
SKELETAL RADIOLOGY, 2000, 29 (09) :520-524
[42]   Optimization of quasi-diffusion magnetic resonance imaging for quantitative accuracy and time-efficient acquisition [J].
Spilling, Catherine A. ;
Howe, Franklyn A. ;
Barrick, Thomas R. .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) :2532-2547
[43]   Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T [J].
Sarlls, Joelle E. ;
Pierpaoli, Carlo .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) :270-276
[44]   Ultrafast T2-weighted imaging of the abdomen and pelvis: Use of single shot fast spin-echo imaging [J].
Tang, Y ;
Yamashita, Y ;
Takahashi, M .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02) :384-390
[45]   MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA [J].
VAHLENSIECK, M ;
LANG, P ;
SEELOS, K ;
SZE, DYH ;
GRAMPP, S ;
REISER, M .
SKELETAL RADIOLOGY, 1994, 23 (08) :607-610
[46]   Time-efficient breath-hold abdominal MRI at 3.0 T [J].
Lauzon, M. Louis ;
Mahallati, Houman ;
Frayne, Richard .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :649-657
[47]   Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver [J].
Altbach, MI ;
Outwater, EK ;
Trouard, TP ;
Krupinski, EA ;
Theilmann, RJ ;
Stopeck, AT ;
Kono, M ;
Gmitro, AF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :179-189
[48]   Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition [J].
Robson, Philip M. ;
Madhuranthakam, Ananth J. ;
Smith, Martin P. ;
Sun, Maryellen R. M. ;
Dai, Weiying ;
Rofsky, Neil M. ;
Pedrosa, Ivan ;
Alsop, David C. .
ACADEMIC RADIOLOGY, 2016, 23 (02) :144-154
[49]   Ultrashort Echo Time and Fast Field Echo Imaging for Spine Bone Imaging with Application in Spondylolysis Evaluation [J].
Vucevic, Diana ;
Malis, Vadim ;
Yamashita, Yuichi ;
Mesa, Anya ;
Yamaguchi, Tomosuke ;
Achar, Suraj ;
Miyazaki, Mitsue ;
Bae, Won C. .
COMPUTATION, 2024, 12 (08)
[50]   Postoperative sella: Evaluation with fast spin echo T2-weighted high-resolution imaging [J].
Nakasu, Y ;
Itoh, R ;
Nakasu, S ;
Nioka, H ;
Kidooka, M ;
Handa, J .
NEUROSURGERY, 1998, 43 (03) :440-446