Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients: A Pilot Study

被引:27
作者
Antonio Merchan-Baeza, Jose [1 ]
Gonzalez-Sanchez, Manuel [1 ]
Ignacio Cuesta-Vargas, Antonio [1 ,2 ]
机构
[1] Univ Malaga, Inst Invest Biomed Malaga IBIMA, Dept Psiquiatria & Fisioterapia, E-29071 Malaga, Spain
[2] Queensland Univ Technol, Sch Clin Sci, Brisbane, Qld 4059, Australia
关键词
TRIAXIAL ACCELEROMETERS; POSTURAL SWAY; GAIT; BALANCE; VALIDITY; FALLS; SCALE;
D O I
10.1155/2014/637671
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Postural instability is one of the major complications found in stroke survivors. Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research. Objectives. To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke. Design. Cross-sectional study. While performing FRT, two inertial sensors were placed on the patient's back (lumbar and trunk). Participants. Five subjects over 65 who suffer from a stroke. Measurements. FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time. Speed and acceleration of the movements were calculated indirectly. Results. FRT measure is 12.75 +/- 2.06 cm. Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement). Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement). FRT's reliability was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject, respectively. Conclusion. The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.
引用
收藏
页数:8
相关论文
共 33 条
[1]   Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers [J].
Aziz, Omar ;
Park, Edward J. ;
Mori, Greg ;
Robinovitch, Stephen N. .
GAIT & POSTURE, 2014, 39 (01) :506-512
[2]   Effects of motor imagery training on balance and gait abilities in post-stroke patients: a randomized controlled trial [J].
Cho, Hwi-young ;
Kim, June-sun ;
Lee, Gyu-Chang .
CLINICAL REHABILITATION, 2013, 27 (08) :675-680
[3]  
Collin C, 1988, Int Disabil Stud, V10, P61
[4]   The use of inertial sensors system for human motion analysis [J].
Cuesta-Vargas, Antonio I. ;
Galan-Mercant, Alejandro ;
Williams, Jonathan M. .
PHYSICAL THERAPY REVIEWS, 2010, 15 (06) :462-473
[5]  
DeWaard B.P., 2002, Journal of Geriatric Physical Therapy, V25, P4, DOI DOI 10.1519/00139143-200225030-00002
[6]   Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test [J].
Doheny, Emer P. ;
Walsh, Cathal ;
Foran, Timothy ;
Greene, Barry R. ;
Fan, Chie Wei ;
Cunningham, Clodagh ;
Kenny, Rose Anne .
GAIT & POSTURE, 2013, 38 (04) :1021-1025
[7]   A reappraisal of reliability and validity studies in stroke [J].
DOlhaberriague, L ;
Litvan, I ;
Mitsias, P ;
Mansbach, HH .
STROKE, 1996, 27 (12) :2331-2336
[8]   Reliability (Inter-rater Agreement) of the Barthel Index for Assessment of Stroke Survivors Systematic Review and Meta-analysis [J].
Duffy, Laura ;
Gajree, Shelley ;
Langhorne, Peter ;
Stott, David J. ;
Quinn, Terence J. .
STROKE, 2013, 44 (02) :462-468
[9]   FUNCTIONAL REACH - A NEW CLINICAL MEASURE OF BALANCE [J].
DUNCAN, PW ;
WEINER, DK ;
CHANDLER, J ;
STUDENSKI, S .
JOURNALS OF GERONTOLOGY, 1990, 45 (06) :M192-M197
[10]   The stroke impact scale version 2.0 - Evaluation of reliability, validity, and sensitivity to change [J].
Duncan, PW ;
Wallace, D ;
Lai, SM ;
Johnson, D ;
Embretson, S ;
Laster, LJ .
STROKE, 1999, 30 (10) :2131-2140