CRP determination based on a novel magnetic biosensor

被引:115
作者
Meyer, Martin H. F.
Hartmann, Markus
Krause, Hans-Joachim
Blankenstein, Gert
Mueller-Chorus, Birgit
Oster, Juergen
Miethe, Peter
Keusgen, Michael [1 ]
机构
[1] Univ Marburg, Inst Pharmaceut Chem, Marburg, Germany
[2] Res Ctr, Inst Thin Films & Interfaces ISG2, Julich, Germany
[3] Boehringer Ingelheim MicroParts, Dortmund, Germany
[4] Chemagen GmbH, Baesweiler, Germany
[5] SENOVA GmbH, Jena, Germany
关键词
c-reactive protein (CRP); magnetic detection; immumosensor; inflammation; CVD; IBD;
D O I
10.1016/j.bios.2006.04.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The c-reactive protein (CRP) is a very significant human blood marker for inflammatory processes and is routinely determined for many clinical purposes. The widespread and well established detection method for this similar to 115 kDa hepatic protein is the high-sensitivity ELISA assay (hsCRP-ELISA) in blood serum. New approaches in medical CRP diagnosis (e.g. for CVD, inflammatory bowel disease) require rapid quantification in native matrices. A novel CRP determination method based on magnetic detection is described and tested for human blood serum, saliva and urine. The detection principle is based on two different anti-CRP antibodies (monoclonal, IgG) for CRP trapment and labelling. The linear detection range of this immunosensor ranged from 25 ng/ml to 2.5 mu g/ml and is therefore much more sensitive than typical hsCRP-ELISA-assays. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:973 / 979
页数:7
相关论文
共 37 条
[1]   Detection of biomolecular interaction between biotin and streptavidin on a self-assembled monolayer using magnetic nanoparticles [J].
Arakaki, A ;
Hideshima, S ;
Nakagawa, T ;
Niwa, D ;
Tanaka, T ;
Matsunaga, T ;
Osaka, T .
BIOTECHNOLOGY AND BIOENGINEERING, 2004, 88 (04) :543-546
[2]   Biomolecular reactions studied using changes in Brownian rotation dynamics of magnetic particles [J].
Astalan, AP ;
Ahrentorp, F ;
Johansson, C ;
Larsson, K ;
Krozer, A .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :945-951
[3]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[4]   C-reactive protein [J].
Black, S ;
Kushner, I ;
Samols, D .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2004, 279 (47) :48487-48490
[5]   Detection and manipulation of biomolecules by magnetic carriers [J].
Brzeska, M ;
Panhorst, M ;
Kamp, PB ;
Schotter, J ;
Reiss, G ;
Pühler, A ;
Becker, A ;
Brückl, H .
JOURNAL OF BIOTECHNOLOGY, 2004, 112 (1-2) :25-33
[6]  
Cabrera-Abreu JC, 2004, ARCH DIS CHILD, V89, P69
[7]   Ultrasensitive magnetic biosensor for homogeneous immunoassay [J].
Chemla, YR ;
Crossman, HL ;
Poon, Y ;
McDermott, R ;
Stevens, R ;
Alper, MD ;
Clarke, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (26) :14268-14272
[8]   An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities [J].
Choi, JW ;
Oh, KW ;
Thomas, JH ;
Heineman, WR ;
Halsall, HB ;
Nevin, JH ;
Helmicki, AJ ;
Henderson, HT ;
Ahn, CH .
LAB ON A CHIP, 2002, 2 (01) :27-30
[9]   Application of microchip assay system for the measurement of C-reactive protein in human saliva [J].
Christodoulides, N ;
Mohanty, S ;
Miller, CS ;
Langub, MC ;
Floriano, PN ;
Dharshan, P ;
Ali, MF ;
Bernard, B ;
Romanovicz, D ;
Anslyn, E ;
Fox, PC ;
McDevitt, JT .
LAB ON A CHIP, 2005, 5 (03) :261-269
[10]   Comparison of differing C-reactive protein assay methods and their impact on cardiovascular risk assessment [J].
Clarke, JL ;
Anderson, JL ;
Carlquist, JF ;
Roberts, RF ;
Horne, BD ;
Bair, TL ;
Kolek, MJ ;
Mower, CP ;
Crane, AM ;
Roberts, WL ;
Muhlestein, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (01) :155-158