Testing of Diamond Electrodes as Biosensor for Antibody-Based Detection of Immunoglobulin Protein with Electrochemical Impedance Spectroscopy

被引:0
作者
Menzler, Martin [1 ]
Ganskow, Charity S. G. [2 ,3 ]
Ruschig, Maximilian [4 ]
Moustafa, Essam [1 ]
Sittinger, Volker [1 ]
Lachmann, Kristina [1 ]
Wenzel, Esther Veronika [4 ]
Russo, Giulio [4 ]
Klahn, Philipp [2 ,3 ]
Gaebler, Jan [1 ]
机构
[1] Fraunhofer Inst Surface Engn & Thin Films IST, Bienroder Weg 54e, D-38108 Braunschweig, Germany
[2] Univ Gothenburg, Dept Chem & Mol Biol, Kemigarden 4, S-42196 Gothenburg, Sweden
[3] NaconLabs Technol Transfer Ctr iTUBS MbH, Wilhelmsgarten 3, D-38100 Braunschweig, Germany
[4] Tech Univ Carolo Wilhelmina Braunschweig, Inst Biochem Biotechnol & Bioinformat, Dept Biotechnol, Spielmannstr 7, D-38106 Braunschweig, Germany
来源
C-JOURNAL OF CARBON RESEARCH | 2022年 / 8卷 / 04期
关键词
biosensing; boron-doped diamond; electrochemical impedance spectroscopy; Fc-Cys engineered antibody; surface immobilisation; atmospheric pressure plasma; 1; 4-conjugate thiol addition; amino group; fluorescence analysis; INFLUENZA-VIRUS DETECTION;
D O I
10.3390/c8040074
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To control the increasing virus pandemics, virus detection methods are essential. Today's standard virus detections methods are fast (immune assays) or precise (PCR). A method that is both fast and precise would enable more efficient mitigation measures and better life comfort. According to recent papers, electrochemical impedance spectroscopy (EIS) has proven to detect viruses fast and precise. Boron-doped diamond (BDD) was used as a high-performance electrode material in these works. The aim of this work was to perform an initial test of BDD-based EIS for biosensing. As an easily available standard biomaterial, human immunoglobulin G (IgG) was used as analyte. Niobium plates were coated via hot-filament activated chemical vapor deposition with polycrystalline diamond, and doped with boron for electrical conductivity. An anti-human IgG antibody was immobilised on the BDD electrodes as a biosensing component. Four different analyte concentrations up to 1.1 mu g per litre were tested. During EIS measurements, both impedance over frequency curves and Nyquist plot demonstrated no clear sign of a change of the charge transfer resistance. Thus, no positive statement about a successful biosensing could be made so far. It is assumed that these issues need to be investigated and improved, including the relation of BDD electrode size to electrolyte volume, termination of the BDD electrodes (H, O) for a successful functionalisation and EIS frequency range. The work will be continued concerning these improvement issues in order to finally use virus materials as analyte.
引用
收藏
页数:11
相关论文
共 20 条
  • [1] SARS-CoV-2 neutralizing human recombinant antibodies selected from pre-pandemic healthy donors binding at RBD-ACE2 interface
    Bertoglio, Federico
    Meier, Doris
    Langreder, Nora
    Steinke, Stephan
    Rand, Ulfert
    Simonelli, Luca
    Heine, Philip Alexander
    Ballmann, Rico
    Schneider, Kai-Thomas
    Roth, Kristian Daniel Ralph
    Ruschig, Maximilian
    Riese, Peggy
    Eschke, Kathrin
    Kim, Yeonsu
    Schaeckermann, Dorina
    Pedotti, Mattia
    Kuhn, Philipp
    Zock-Emmenthal, Susanne
    Woehrle, Johannes
    Kilb, Normann
    Herz, Tobias
    Becker, Marlies
    Grasshoff, Martina
    Wenzel, Esther Veronika
    Russo, Giulio
    Kroeger, Andrea
    Brunotte, Linda
    Ludwig, Stephan
    Fuehner, Viola
    Kraemer, Stefan Daniel
    Duebel, Stefan
    Varani, Luca
    Roth, Gunter
    Cicin-Sain, Luka
    Schubert, Maren
    Hust, Michael
    [J]. NATURE COMMUNICATIONS, 2021, 12 (01)
  • [2] Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation
    Bialobrzeska, Wioleta
    Ficek, Mateusz
    Dec, Bartlomiej
    Osella, Silvio
    Trzaskowski, Bartosz
    Jaramillo-Botero, Andres
    Pierpaoli, Mattia
    Rycewicz, Michal
    Dashkevich, Yanina
    Lega, Tomasz
    Malinowska, Natalia
    Cebula, Zofia
    Bigus, Daniel
    Firganek, Daniel
    Biega, Ewelina
    Dziabowska, Karolina
    Brodowski, Mateusz
    Kowalski, Marcin
    Panasiuk, Miroslawa
    Gromadzka, Beata
    Zoledowska, Sabina
    Nidzworski, Dawid
    Pyrc, Krzysztof
    Goddard, William A., III
    Bogdanowicz, Robert
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 209
  • [3] Current methods and prospects of coronavirus detection
    Bu, Jiaqi
    Deng, Zhiwei
    Liu, Hui
    Li, Jiacheng
    Wang, De
    Yang, Yanjing
    Zhong, Shian
    [J]. TALANTA, 2021, 225
  • [4] Electrochemical Determination of Interaction between SARS-CoV-2 Spike Protein and Specific Antibodies
    Drobysh, Maryia
    Liustrovaite, Viktorija
    Baradoke, Ausra
    Rucinskiene, Alma
    Ramanaviciene, Almira
    Ratautaite, Vilma
    Viter, Roman
    Chen, Chien-Fu
    Plikusiene, Ieva
    Samukaite-Bubniene, Urte
    Slibinskas, Rimantas
    Ciplys, Evaldas
    Simanavicius, Martynas
    Zvirbliene, Aurelija
    Kucinskaite-Kodze, Indre
    Ramanavicius, Arunas
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (12)
  • [5] Getting Through COVID-19: The Pandemic's Impact on the Psychology of Sustainability, Quality of Life, and the Global Economy - A Systematic Review
    El Keshky, Mogeda El Sayed
    Basyouni, Sawzan Sadaqa
    Al Sabban, Abeer Mohammad
    [J]. FRONTIERS IN PSYCHOLOGY, 2020, 11
  • [6] Fabrication and application of Diachem® electrodes
    Fryda, M
    Matthée, T
    Mulcahy, S
    Hampel, A
    Schäfer, L
    Tröster, I
    [J]. DIAMOND AND RELATED MATERIALS, 2003, 12 (10-11) : 1950 - 1956
  • [7] Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art
    Khan, M. Z. H.
    Hasan, M. R.
    Hossain, S., I
    Ahommed, M. S.
    Daizy, M.
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 166
  • [8] SARS-CoV-2 Aptasensors Based on Electrochemical Impedance Spectroscopy and Low-Cost Gold Electrode Substrates
    Lasserre, Perrine
    Balansethupathy, Banushan
    Vezza, Vincent J.
    Butterworth, Adrian
    Macdonald, Alexander
    Blair, Ewen O.
    McAteer, Liam
    Hannah, Stuart
    Ward, Andrew C.
    Hoskisson, Paul A.
    Longmuir, Alistair
    Setford, Steven
    Farmer, Eoghan C. W.
    Murphy, Michael E.
    Flynn, Harriet
    Corrigan, Damion K.
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (04) : 2126 - 2133
  • [9] Towards an Electrochemical Immunosensor for the Detection of Antibodies against SARS-CoV-2 Spike Protein
    Liustrovaite, Viktorija
    Drobysh, Maryia
    Rucinskiene, Alma
    Baradoke, Ausra
    Ramanaviciene, Almira
    Plikusiene, Ieva
    Samukaite-Bubniene, Urte
    Viter, Roman
    Chen, Chien-Fu
    Ramanavicius, Arunas
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (03)
  • [10] Analytical Applications of Electrochemically Pretreated Boron-Doped Diamond Electrodes
    Lourencao, Bruna C.
    Brocenschi, Ricardo F.
    Medeiros, Roberta A.
    Fatibello-Filho, Orlando
    Rocha-Filho, Romeu C.
    [J]. CHEMELECTROCHEM, 2020, 7 (06): : 1291 - 1311