A volume of intersection approach for on-the-fly system matrix calculation in 3D PET image reconstruction

被引:16
|
作者
Lougovski, A. [1 ]
Hofheinz, F. [1 ]
Maus, J. [1 ]
Schramm, G. [1 ]
Will, E. [1 ]
van den Hoff, J. [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Radiopharmaceut Canc Res, PET Ctr, D-01328 Dresden, Germany
[2] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Nucl Med, D-01307 Dresden, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 03期
关键词
volume of intersection; tube of response; on-the-fly system matrix calculation; image reconstruction; 3D; list-mode; PET; SINGLE SCATTER SIMULATION; LIST-MODE RECONSTRUCTION; ALGORITHM; IMPLEMENTATION; PERFORMANCE; PHANTOM; DESIGN; SPHERE;
D O I
10.1088/0031-9155/59/3/561
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study is the evaluation of on-the-fly volume of intersection computation for system's geometry modelling in 3D PET image reconstruction. For this purpose we propose a simple geometrical model in which the cubic image voxels on the given Cartesian grid are approximated with spheres and the rectangular tubes of response (ToRs) are approximated with cylinders. The model was integrated into a fully 3D list-mode PET reconstruction for performance evaluation. In our model the volume of intersection between a voxel and the ToR is only a function of the impact parameter (the distance between voxel centre to ToR axis) but is independent of the relative orientation of voxel and ToR. This substantially reduces the computational complexity of the system matrix calculation. Based on phantom measurements it was determined that adjusting the diameters of the spherical voxel size and the ToR in such a way that the actual voxel and ToR volumes are conserved leads to the best compromise between high spatial resolution, low noise, and suppression of Gibbs artefacts in the reconstructed images. Phantom as well as clinical datasets from two different PET systems (Siemens ECAT HR+ and Philips Ingenuity-TF PET/MR) were processed using the developed and the respective vendor-provided (line of intersection related) reconstruction algorithms. A comparison of the reconstructed images demonstrated very good performance of the new approach. The evaluation showed the respective vendor-provided reconstruction algorithms to possess 34-41% lower resolution compared to the developed one while exhibiting comparable noise levels. Contrary to explicit point spread function modelling our model has a simple straight-forward implementation and it should be easy to integrate into existing reconstruction software, making it competitive to other existing resolution recovery techniques.
引用
收藏
页码:561 / 577
页数:17
相关论文
共 50 条
  • [1] Modelling of Scatter in the System Matrix for 3D PET Image Reconstruction: a Comparative Study
    Schaar, Moritz
    Rafecas, Magdalena
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [2] AN EXACT ANALYTIC APPROACH TO 3D PET IMAGE RECONSTRUCTION
    Kao, Chien-Min
    Zou, Yu
    Cho, Seungryong
    Pan, Xiaochuan
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2007, 7 (01) : 35 - 54
  • [3] Calculation of bone graft volume using 3D reconstruction system
    Calvo-Guirado, Jose-Luis
    Mate-Sanchez, Jose-Eduardo
    Delgado-Ruiz, Rafael
    Ramirez-Fernandez, Maria-Piedad
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (02): : E260 - E264
  • [4] BRIGHTEARTH: PIPELINE FOR ON-THE-FLY 3D RECONSTRUCTION OF URBAN AND RURAL SCENES FROM ONE SATELLITE IMAGE
    Tripodi, S.
    Girard, N.
    Fonteix, G.
    Duan, L.
    Mapurisa, W.
    Leras, M.
    Trastour, F.
    Tarabalka, Y.
    Laurore, L.
    XXIV ISPRS CONGRESS: IMAGING TODAY, FORESEEING TOMORROW, COMMISSION III, 2022, 5-3 : 263 - 270
  • [5] PET Image Reconstruction Using LOR-OSEM with a 3D Spatially Variant System Matrix
    Wiant, David B.
    Gersh, Jacob A.
    Bennett, Marcus C.
    Bourland, J. Daniel
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3752 - 3758
  • [6] Analytical volume calculation of voxel fragments for iterative, fully 3D PET reconstruction
    Scheins, JJ
    Herzog, H
    Boschen, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2502 - 2506
  • [7] 3D shape reconstruction using volume intersection techniques
    Carr, JC
    Fright, WR
    Geel, AH
    Prager, RW
    Dalton, KJ
    SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 1095 - 1100
  • [8] Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation
    Gillam, J. E.
    Solevi, P.
    Oliver, J. F.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2377 - 2394
  • [9] 'On-the-Fly' 3D System Allows for Quick Changes While Printing
    不详
    MANUFACTURING ENGINEERING, 2016, 157 (02): : 35 - 36
  • [10] An Efficient Approach to 3D Image Reconstruction
    Al-Shayea, Qeethara Kadhim
    Al-Ani, Muzhir Shaban
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2016, 16 (08): : 35 - 41