Bionate Lumbar Disc Nucleus Prosthesis: Biomechanical Studies in Cadaveric Human Spines

被引:3
|
作者
Vanaclocha, Amparo [1 ]
Vanaclocha, Vicente [7 ]
Atienza, Carlos M. [1 ,4 ]
Clavel, Pablo [2 ,3 ]
Jorda-Gomez, Pablo
Barrios, Carlos
Saiz-Sapena, Nieves [5 ]
Vanaclocha, Leyre [6 ]
机构
[1] Biomech Inst Valencia, Valencia 46022, Spain
[2] Hosp Quironsalud Barcelona, Inst Clavel, Barcelona 08023, Spain
[3] Hosp Gen Univ Castellon, Castellon De La Plana 12004, Spain
[4] Catholic Univ Valencia, St Vincent Martyr, Valencia 46001, Spain
[5] Hosp Gen Univ Valencia, Valencia 46014, Spain
[6] Ostfildern Ruit Klin Urol, Medius Klin, D-73760 Ostfildern, Germany
[7] Univ Valencia, Valencia 46010, Spain
来源
ACS OMEGA | 2022年 / 7卷 / 50期
关键词
INTERVERTEBRAL DISC; PULPOSUS REPLACEMENT; IN-VITRO; HYDROGELS; REGENERATION; IMPLANT; BIOMATERIALS; COMPRESSION; INSTABILITY; NUCLEOTOMY;
D O I
10.1021/acsomega.2c05294
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Design: cadaveric spine nucleus replacement study. Objective: determining Bionate 80A nucleus replacement bio-mechanics in cadaveric spines. Methods: in cold preserved spines, with ligaments and discs intact, and no muscles, L3-L4, L4-L5, and L5 -S1 nucleus implantation was done. Differences between customized and overdimensioned implants were compared. Flexion, extension, lateral bending, and torsion were measured in the intact spine, nucleotomy, and nucleus implantation specimens. Increasing load or bending moment was applied four times at 2, 4, 6, and 8 Nm, twice in increasing mode and twice in decreasing mode. Spine motion was recorded using stereophotogrammetry. Expulsion tests: cyclic compression of 50-550 N for 50,000 cycles, increasing the load until there was extreme flexion, implant extrusion, or anatomical structure collapse. Subsidence tests were done by increasing the compression to 6000 N load. Results: nucleotomy increased the disc mobility, which remained unchanged for the adjacent upper level but increased for the lower adjacent one, particularly in lateral bending and torsion. Nucleus implantation, compared to nucleotomy, reduced disc mobility except in flexion -extension and torsion, but intact mobility was no longer recovered, with no effect on upper or lower adjacent segments. The overdimensioned implant, compared to the customized implant, provided equal or sometimes higher mobility. Lamina, facet joint, and annulus removal during nucleotomy caused more damaged than that restored by nucleus implantation. No implant extrusion was observed under compression loads of 925-1068 N as anatomical structures collapsed before. No subsidence or vertebral body fractures were observed under compression loads of 6697.8-6812.3 N. Conclusions: nucleotomized disc and L1-S1 mobility increased moderately after cadaveric spine nucleus implantation compared to the intact status, partly due to operative anatomical damage. Our implant had shallow expulsion and subsidence risks.
引用
收藏
页码:46501 / 46514
页数:14
相关论文
共 50 条
  • [31] Biomechanical Characteristics of Kissing Spine During Extension Using a Human Cadaveric Lumbar Spinal Model
    Kasai, Yuichi
    Kato, Takaya
    Inaba, Tadashi
    Baba, Sotaro
    Paholpak, Permsak
    Wisanuyotin, Taweechok
    Kosuwon, Weerachai
    Hirata, Hirohito
    Morimoto, Tadatsugu
    ORTHOPEDIC RESEARCH AND REVIEWS, 2024, 16 : 199 - 203
  • [32] The role of the nucleus pulposus in neutral zone human lumbar intervertebral disc mechanics
    Cannella, Marco
    Arthur, Amy
    Allen, Shanee
    Keane, Michael
    Joshi, Abhijeet
    Vresilovic, Edward
    Marcolongo, Michele
    JOURNAL OF BIOMECHANICS, 2008, 41 (10) : 2104 - 2111
  • [33] Gene expression profiling in nucleus pulposus of human ruptured lumbar disc herniation
    Li, Xiaochun
    Shen, Xueqiang
    Wang, Zhiqiang
    Jiang, Hong
    Ma, Zhijia
    Yu, Pengfei
    Yu, Zhenhan
    Qian, Xiang
    Liu, Jintao
    FRONTIERS IN PHARMACOLOGY, 2022, 13
  • [34] Augmentation Improves Human Cadaveric Vertebral Body Compression Mechanics for Lumbar Total Disc Replacement
    Yoder, Jonathon H.
    Auerbach, Joshua D.
    Maurer, Philip M.
    Erbe, Erik M.
    Entrekin, Dean
    Balderston, Richard A.
    Bertagnoli, Rudolf
    Elliott, Dawn M.
    SPINE, 2010, 35 (09) : E325 - E331
  • [35] The research of transgenic human nucleus pulposus cell transplantation in the treatment of lumbar disc degeneration
    Wang, Hua-Cong
    Jin, Cang-Hai
    Kong, Jie
    Yu, Tao
    Guo, Jian-Wei
    Hu, You-Gu
    Liu, Yong
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2019, 35 (08): : 486 - 492
  • [36] Biomechanical stability with a new implant for vertebral body replacement. 3-dimensional motion analysis on human cadaveric spines
    Knop, C
    Lange, U
    Bastian, L
    Blauth, M
    UNFALLCHIRURG, 2001, 104 (10): : 984 - 997
  • [37] Nucleus implant parameters significantly change the compressive stiffness of the human lumbar intervertebral disc
    Joshi, A
    Mehta, S
    Vresilovic, E
    Karduna, A
    Marcolongo, M
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 536 - 540
  • [38] Biomechanical analysis in a human cadaveric model of spinous process fixation with an interlaminar allograft spacer for lumbar spinal stenosis
    Pradhan, Ben B.
    Turner, Alexander W. L.
    Zatushevsky, Michael A.
    Cornwall, G. Bryan
    Rajaee, Sean S.
    Bae, Hyun W.
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 16 (06) : 585 - 593
  • [39] Biomechanical fixation properties of cortical versus transpedicular screws in the osteoporotic lumbar spine: an in vitro human cadaveric model
    Sansur, Charles A.
    Caffes, Nicholas M.
    Ibrahimi, David M.
    Pratt, Nathan L.
    Lewis, Evan M.
    Murgatroyd, Ashley A.
    Cunningham, Bryan W.
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (04) : 467 - 476
  • [40] Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model
    Kotani, Yoshihisa
    Cunningham, Bryan W.
    Abumi, Kuniyoshi
    Dmitriev, Anton E.
    Hu, Niabin
    Ito, Manabu
    Shikinami, Yasuo
    McAfee, Paul C.
    Minami, Akio
    EUROPEAN SPINE JOURNAL, 2006, 15 (10) : 1511 - 1520