High-resolution mantle tomography of China and surrounding regions

被引:1200
|
作者
Huang, Jinli [1 ]
Zhao, Dapeng
机构
[1] China Earthquake Adm, Inst Earthquake Sci, Beijing 100036, Peoples R China
[2] Ehime Univ, Geodynam Res Ctr, Matsuyama, Ehime 7908577, Japan
关键词
D O I
10.1029/2005JB004066
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
[ 1] A high-resolution P wave tomographic model of the crust and mantle down to 1100 km depth under China and surrounding regions is determined by using about one million arrival times of P, pP, PP, and PcP waves from 19,361 earthquakes recorded by 1012 seismic stations. The subducting Pacific slab is imaged clearly as a high-velocity zone from the oceanic trenches down to about 600 km depth, and intermediate-depth and deep earthquakes are located within the slab. The Pacific slab becomes stagnant in the mantle transition zone under east China. The western edge of the stagnant slab is roughly coincident with a surface topographic boundary in east China. The active Changbai and Wudalianchi intraplate volcanoes in northeast China are underlain by significant slow anomalies in the upper mantle, above the stagnant Pacific slab. These results suggest that the active intraplate volcanoes in NE China are not hot spots but a kind of back-arc volcano associated with the deep subduction of the Pacific slab and its stagnancy in the transition zone. Under the Mariana arc, however, the Pacific slab penetrates directly down to the lower mantle. The active Tengchong volcano in southwest China is related to the eastward subduction of the Burma microplate. The subducting Indian and Philippine Sea plates are also imaged clearly. The Indian plate has subducted down to 200 - 300 km depth under the Tibetan Plateau with a horizontal moving distance of about 500 km. High-velocity anomalies are revealed in the upper mantle under the Tarim basin, Ordos, and Sichuan basin, which are three stable blocks in China.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] High-resolution computed tomography: Technique and pitfalls
    McGuinness, G
    SEMINARS IN ROENTGENOLOGY, 2002, 37 (01) : 5 - 16
  • [32] High-resolution computed tomography in rheumatoid arthritis
    Sema Yildiz
    Hasan Cece
    Ekrem Karakas
    Rheumatology International, 2012, 32 : 3703 - 3703
  • [33] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE LUNGS
    WORTHY, S
    BRITISH MEDICAL JOURNAL, 1995, 310 (6980): : 615 - 616
  • [34] HIGH-RESOLUTION COMPUTED TOMOGRAPHY IN ALVEOLAR PROTEINOSIS
    Mehrian, P.
    CHEST, 2020, 157 (06) : 218A - 218A
  • [35] High-resolution computed tomography in rheumatoid arthritis
    Yildiz, Sema
    Cece, Hasan
    Karakas, Ekrem
    RHEUMATOLOGY INTERNATIONAL, 2012, 32 (11) : 3703 - 3703
  • [36] A HIGH-RESOLUTION DETECTION SYSTEM FOR POSITRON TOMOGRAPHY
    BARTON, JB
    HOFFMAN, EJ
    IWANCZYK, JS
    DABROWSKI, AJ
    KUSMISS, JH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 671 - 675
  • [37] HIGH-RESOLUTION COMPUTED TOMOGRAPHY OF POSITRON EMITTERS
    DERENZO, SE
    BUDINGER, TF
    CAHOON, JL
    HUESMAN, RH
    JACKSON, HG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 544 - 558
  • [38] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE LUNG
    SWENSEN, SJ
    AUGHENBAUGH, GL
    BROWN, LR
    MAYO CLINIC PROCEEDINGS, 1989, 64 (10) : 1284 - 1294
  • [39] High-resolution process in ultrasonic reflection tomography
    Lasaygues, P
    Lefebvre, JP
    Bouvat-Merlin, M
    ACOUSTICAL IMAGING, VOL 24, 2000, 24 : 35 - 41
  • [40] THE HIGH-RESOLUTION COMPUTED-TOMOGRAPHY TECHNIQUE
    MAYO, JR
    SEMINARS IN ROENTGENOLOGY, 1991, 26 (02) : 104 - 109