An analytical method for the analysis of tulathromycin, an equilibrating triamilide, in bovine and porcine plasma and lung

被引:44
作者
Gáler, D
Hessong, S
Beato, B
Risk, J
Inskeep, P
Weerasinghe, C
Schneider, RP
Langer, C
LaPerle, J
Renouf, D
Bessire, A
Español, E
Rafka, R
Ragan, C
Boettner, W
Murphy, T
Keller, D
Benchaoui, H
Nowakowski, MA
机构
[1] Pfizer Inc, Pfizer Global Res & Dev, Groton Labs, Terre Haute, IN 47808 USA
[2] Terre Haute Labs, Terre Haute, IN 47808 USA
[3] Pfizer Ltd, Pfizer Anim Hlth Grp Vet Med Res & Dev, Sandwich CT13 9NJ, Kent, England
[4] BASi, W Lafayette, IN 47906 USA
关键词
triamilide antibiotics; tulathromycin; mass spectrometry; swine; swine plasma; swine lung; cattle; cattle plasma; cattle lung; pharmacokinetics;
D O I
10.1021/jf0351624
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Tulathromycin is a novel member of the triamilide class of antibiotics that was developed as a safe and effective single-dose treatment of bovine and porcine respiratory disease. An accurate and precise analytical method was developed for the extraction and measurement of tulathromycin in livestock plasma and lung homogenates. Analytes were solid-phase extracted onto a weak cation exchanger after aqueous dilution of samples and addition of heptadeutero-tulathromycin as an internal standard. Following HPLC with a narrow bore C8 column, quantitative detection of tulathromycin was accomplished by monitoring the transition of a doubly charged precursor ion to a singly charged product ion by tandem mass spectrometry using a triple quadrupole mass spectrometer. Procedures were validated for a dynamic range of 0.1 to 25 ng on column. Observed accuracies were between 90 and 110% of nominal and precision (RSD) varying 7% or less. Response and stability experiments showed that deuterated tulathromycin did not parallel the chemical behavior of tulathromycin. Applicability of the method to livestock studies was tested with plasma and lung samples from cattle and swine dosed with tulathromycin at multiple doses. The results demonstrated that the analytical method performed well in a range of sample concentrations spanning over 3 orders of magnitude and provided dose-exposure relationships for cattle and swine.
引用
收藏
页码:2179 / 2191
页数:13
相关论文
共 23 条
[1]  
BENCHAOUI HA, 2004, UNPUB J VET PHARM TH
[2]   Liquid chromatography analysis of erythromycin A in salmon tissue by electrochemical detection with confirmation by electrospray ionization mass spectrometry [J].
Billedeau, SM ;
Heinze, TM ;
Siitonen, PH .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (06) :1534-1538
[3]  
BOETTNER WA, 2003, Patent No. 6514945
[4]   SYNTHESIS, INVITRO AND INVIVO ACTIVITY OF NOVEL 9-DEOXO-9A-AZA-9A-HOMOERYTHROMYCIN A DERIVATIVES - A NEW CLASS OF MACROLIDE ANTIBIOTICS, THE AZALIDES [J].
BRIGHT, GM ;
NAGEL, AA ;
BORDNER, J ;
DESAI, KA ;
DIBRINO, JN ;
NOWAKOWSKA, J ;
VINCENT, L ;
WATROUS, RM ;
SCIAVOLINO, FC ;
ENGLISH, AR ;
RETSEMA, JA ;
ANDERSON, MR ;
BRENNAN, LA ;
BOROVOY, RJ ;
CIMOCHOWSKI, CR ;
FAIELLA, JA ;
GIRARD, AE ;
GIRARD, D ;
HERBERT, C ;
MANOUSOS, M ;
MASON, R .
JOURNAL OF ANTIBIOTICS, 1988, 41 (08) :1029-1047
[5]   Pharmacodynamics of macrolides, azalides, and streptogramins: Effect on extracellular pathogens [J].
Carbon, C .
CLINICAL INFECTIOUS DISEASES, 1998, 27 (01) :28-32
[6]   Quantitation of tylosin in swine tissues by liquid chromatography combined with electrospray ionization mass spectrometry [J].
Cherlet, M ;
De Baere, S ;
Croubels, S ;
De Backer, P .
ANALYTICA CHIMICA ACTA, 2002, 473 (1-2) :167-175
[7]   Residue analysis of macrolides in poultry muscle by liquid chromatography-electrospray mass spectrometry [J].
Codony, R ;
Compañó, R ;
Granados, M ;
García-Regueiro, JA ;
Prat, MD .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :131-141
[8]  
DARRINGTON RT, 2003, AAPS PHARMSCI, V5
[9]   Liquid chromatographic-mass spectrometric methods for analyzing antibiotic and antibacterial agents in animal food products [J].
Di Corcia, A ;
Nazzari, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :53-89
[10]   Confirmatory method for macrolide residues in bovine tissues by micro-liquid chromatography-tandem mass spectrometry [J].
Draisci, R ;
Palleschi, L ;
Ferretti, E ;
Achene, L ;
Cecilia, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :97-104