Evaluation of a radiotherapy protocol based on INT0116 for completely resected gastric adenocarcinoma

被引:16
作者
Chung, HT
Shakespeare, TP
Wynne, CJ
Lu, JJ
Mukherjee, RK
Back, MF
机构
[1] British Columbia Canc Agcy, Dept Radiat Oncol, Vancouver, BC V5Z 4E6, Canada
[2] Natl Univ Singapore Hosp, Inst Canc, Radiotherapy Ctr, Singapore 117548, Singapore
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 59卷 / 05期
关键词
observer variation; conformal radiotherapy; gastric cancer; treatment planning;
D O I
10.1016/j.ijrobp.2004.01.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: With the results of the INT0116 study, adjuvant radiochemotherapy has become the standard treatment after complete resection of gastric adenocarcinoma. However, the implementation of radiotherapy (RT) remains a concern. In response, consensus guidelines on RT technique have been published. Our objective was to measure the inter- and intraclinician variability in RT field delineation using conventional two- (2D) and three-dimensional (3D) techniques. Methods and Materials: Between 1999 and 2003, five radiation oncologists (ROs) treated 45 patients with completely resected, gastric adenocarcinoma using postoperative radiochemotherapy (INT0116). Two cases were included in this study (Patient 1 had cardia and Patient 2 had antral disease). Standardized vignettes (with surgical and pathologic findings) and preoperative and postoperative imaging for each case were developed. Each RO designed AP-PA fields for each patient (2D planning) on two separate occasions. This was repeated using a 3D planning technique. Results: Patient 1 had a mean field area of 250.2 cm(2) (SD 12.0) and 227.9 cm(2) (SD 26.5) using 2D and 3D planning, respectively (p = 0.03). The mean clinical target volume (CTV) volume was 468.3 cm(3) (SD 65.9). Patient 1 had a significantly greater inter- than intra-RO variation for the field area designed with 3D planning; however, no difference occurred with 2D planning or CTV contouring. Patient 2 had a mean field area of 234.8 cm(2) (SD 33.1) and 226.8 cm(2) (SD 19.3) using 2D and 3D planning, respectively (p = 0.5). The mean CTV was 729.4 cm(3) (SD 67.3). For Patient 2, the inter-RO variability was significantly greater than the intra-RO variability for the field area using both 2D and 3D planning, and no difference was seen for the CTV. Composite beam's-eye-view plots revealed that the superior, inferior, and right lateral borders proved to be most contentious. Conclusion: Despite published guidelines and a departmental protocol, significant variations in the RT field areas were seen among ROs for both 2D and 3D planning. However, in general, CTV contouring was reproducible. Because 3D-RT hinges on accurate target identification, caution should be exercised before migrating to 3D planning for postoperative gastric cancer. (C) 2004 Elsevier Inc.
引用
收藏
页码:1446 / 1453
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]  
[Anonymous], 1999, 62 ICRU
[3]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[4]  
Bland JM, 1996, BRIT MED J, V313, P744
[5]   Rectum contouring variability in patients treated for prostate cancer: impact on rectum dose-volume histograms and normal tissue complication probability [J].
Fiorino, C ;
Vavassori, V ;
Sanguineti, G ;
Bianchi, C ;
Cattaneo, GM ;
Piazzolla, A ;
Cozzarini, C .
RADIOTHERAPY AND ONCOLOGY, 2002, 63 (03) :249-255
[6]   Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning [J].
Fiorino, C ;
Reni, M ;
Bolognesi, A ;
Cattaneo, GM ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :285-292
[7]   ADENOCARCINOMA OF THE STOMACH - AREAS OF FAILURE IN A REOPERATION SERIES (2ND OR SYMPTOMATIC LOOK) CLINICOPATHOLOGIC CORRELATION AND IMPLICATIONS FOR ADJUVANT THERAPY [J].
GUNDERSON, LL ;
SOSIN, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (01) :1-11
[8]   Variability in target volume delineation on CT scans of the breast [J].
Hurkmans, CW ;
Borger, JH ;
Pieters, BR ;
Russell, NS ;
Jansen, EPM ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1366-1372
[9]   Clinical variability of target volume description in conformal radiotherapy planning [J].
Logue, JP ;
Sharrock, CL ;
Cowan, RA ;
Read, G ;
Marrs, J ;
Mott, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :929-932
[10]   Optimization of dose distributions for adjuvant loco-regional radiotherapy of gastric cancer by IMRT [J].
Lohr, F ;
Dobler, B ;
Mai, S ;
Hermann, B ;
Tiefenbacher, U ;
Wieland, P ;
Steil, V ;
Wenz, F .