Complex study on compression of ECG signals using novel single-cycle fractal-based algorithm and SPIHT

被引:5
作者
Nemcova, Andrea [1 ]
Vitek, Martin [1 ]
Novakova, Marie [2 ]
机构
[1] Brno Univ Technol, Fac Elect Engn & Commun, Dept Biomed Engn, Tech 12, Brno 61600, Czech Republic
[2] Masaryk Univ, Fac Med, Dept Physiol, Kamenice 753-5, Brno 62500, Czech Republic
关键词
ELECTROCARDIOGRAM SIGNAL; RECOMMENDATIONS; DECOMPOSITION; IMPACT;
D O I
10.1038/s41598-020-72656-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Compression of ECG signal is essential especially in the area of signal transmission in telemedicine. There exist many compression algorithms which are described in various details, tested on various datasets and their performance is expressed by different ways. There is a lack of standardization in this area. This study points out these drawbacks and presents new compression algorithm which is properly described, tested and objectively compared with other authors. This study serves as an example how the standardization should look like. Single-cycle fractal-based (SCyF) compression algorithm is introduced and tested on 4 different databases-CSE database, MIT-BIH arrhythmia database, High-frequency signal and Brno University of Technology ECG quality database (BUT QDB). SCyF algorithm is always compared with well-known algorithm based on wavelet transform and set partitioning in hierarchical trees in terms of efficiency (2 methods) and quality/distortion of the signal after compression (12 methods). Detail analysis of the results is provided. The results of SCyF compression algorithm reach up to avL=0.4460 bps and PRDN=2.8236%.
引用
收藏
页数:15
相关论文
共 58 条
[1]   ECG compression retaining the best natural basis k-coefficients via sparse decomposition [J].
Adamo, Alessandro ;
Grossi, Giuliano ;
Lanzarotti, Raffaella ;
Lin, Jianyi .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 15 :11-17
[2]   An Adaptive Run Length Encoding method for the compression of electrocardiograms [J].
Agulhari, Cristiano M. ;
Bonatti, Ivanil S. ;
Peres, Pedro L. D. .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (02) :145-153
[3]  
Al-Shammary D., 2011, 2011 Proceedings of IEEE International Conference on Services Computing (SCC 2011), P96, DOI 10.1109/SCC.2011.15
[4]  
[Anonymous], 2019, WHO LAUNCH DIG APP I
[5]  
[Anonymous], 2014, CARD DIS CVDS
[6]  
Balevi E., 2019, P IEEE GLOB COMM C G, P1, DOI [10.1109/MeMeA.2019.8802184, DOI 10.1109/MEMEA.2019.8802184]
[7]   Preserving Abnormal Beat Morphology in Long-Term ECG Recording: An Efficient Hybrid Compression Approach [J].
Bera, Priyanka ;
Gupta, Rajarshi ;
Saha, Jayanta .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) :2084-2092
[8]   Compression of electrocardiogram signals using JPEG2000 [J].
Bilgin, A ;
Marcellin, MW ;
Altbach, MI .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2003, 49 (04) :833-840
[9]   Impact of compressed sensing on clinically relevant metrics for ambulatory ECG monitoring [J].
Craven, D. ;
McGinley, B. ;
Kilmartin, L. ;
Glavin, M. ;
Jones, E. .
ELECTRONICS LETTERS, 2015, 51 (04) :323-324
[10]   Quantification of Diagnostic Information from Electrocardiogram Signal: A Review [J].
Dandapat, S. ;
Sharma, L. N. ;
Tripathy, R. K. .
ADVANCES IN COMMUNICATION AND COMPUTING, 2015, 347 :17-39