Accuracy in tumor size measurements: Comparison of digital mammography, digital breast tomosynthesis and synthetic mammography

被引:3
作者
Sendur, Halit Nahit [1 ]
Cerit, Mahi Nur [1 ]
Gultekin, Serap [1 ]
Cindil, Emetullah [1 ]
Aslan, Aydan Avdan [1 ]
Erdal, Zeynep Sezgi [1 ]
Gultekin, Isil Imge [1 ]
Teke, Furkan [1 ]
机构
[1] Gazi Univ, Fac Med, Dept Radiol, Mevlana Bulvari 29, TR-06560 Ankara, Turkey
关键词
Digital mammography; Digital breast tomosynthesis; Synthetic mammography; Tumor size; Accuracy; DIAGNOSTIC-ACCURACY; PREOPERATIVE ASSESSMENT; SONOGRAPHY; PREDICTION; DENSITY; MRI;
D O I
10.1016/j.clinimag.2020.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to assess the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography (SM) in tumor size measurements compared with histological tumor sizes. Materials and methods: 71 breast cancer patients who underwent DM and DBT acquisitions simultaneously were included in this study. One radiologist with 8 years of experience in breast imaging measured tumor sizes independently in three separate sessions which include DM, DBT and SM images, respectively. The correlations between the measured tumor sizes on each imaging technique and histological sizes were analyzed using Spearman correlation test. The patients were categorized into two subgroups according to assigned breast density categories (dense and non-dense), and histological tumor sizes (<= 2 cm and > 2 cm). To assess the agreement levels between the measured tumor sizes and histological sizes Bland-Altman analyses were performed for each imaging technique. Results: The mean of histological size of tumors was 23.85 16.57 mm (median: 20). The means of measured tumor sizes were 21.21 +/- 13.59 mm (median: 19), 21.52 +/- 13.42 mm (median: 19) and 18.97 +/- 11.21 mm (median: 17) in DM, DBT and SM, respectively. The Spearman correlation values with histologic sizes were 0.814 (P < 0.001), 0.887 (P < 0.001), and 0.852 (P < 0.001) for DM, DBT and SM, respectively. In subgroup analyses, the correlation values showed decrement for tumors 2 cm in size compared to tumors <= 2 cm in size. Conclusion: DBT provides the most accurate tumor size measurements among mammographic imaging techniques and if mammography will be used in tumor size measurements, DBT should be preferred.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 2020, CANC FACTS FIG 2015
[2]   Breast Cancer Screening with Digital Breast Tomosynthesis: Are Initial Benefits Sustained? [J].
Bahl, Manisha ;
Mercaldo, Sarah ;
Dang, Pragya A. ;
Mccarthy, Anne Marie ;
Lowry, Kathryn P. ;
Lehman, Constance D. .
RADIOLOGY, 2020, 295 (03) :529-539
[3]   Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer [J].
Berg, WA ;
Gutierrez, L ;
NessAiver, MS ;
Carter, WB ;
Bhargavan, M ;
Lewis, RS ;
Ioffe, OB .
RADIOLOGY, 2004, 233 (03) :830-849
[4]   Five Consecutive Years of Screening with Digital Breast Tomosynthesis: Outcomes by Screening Year and Round [J].
Conant, Emily F. ;
Zuckerman, Samantha P. ;
Mcdonald, Elizabeth S. ;
Weinstein, Susan P. ;
Korhonen, Katrina E. ;
Birnbaum, Julia A. ;
Tobey, Jennifer D. ;
Schnall, Mitchell D. ;
Hubbard, Rebecca A. .
RADIOLOGY, 2020, 295 (02) :285-293
[5]   International Variation in Female Breast Cancer Incidence and Mortality Rates [J].
DeSantis, Carol E. ;
Bray, Freddie ;
Ferlay, Jacques ;
Lortet-Tieulent, Joannie ;
Anderson, Benjamin O. ;
Jemal, Ahmedin .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2015, 24 (10) :1495-1506
[6]   Prediction of breast tumor size by mammography and sonography - A breast screen experience [J].
Dummin, L. J. ;
Cox, M. ;
Plant, L. .
BREAST, 2007, 16 (01) :38-46
[7]   Synthesized Mammography: Clinical Evidence, Appearance, and Implementation [J].
Durand, Melissa A. .
DIAGNOSTICS, 2018, 8 (02)
[8]   Influence of mammographic density on the diagnostic accuracy of tumor size assessment and association with breast cancer tumor characteristics [J].
Fasching, Peter A. ;
Heusinger, Katharina ;
Loehberg, Christian R. ;
Wenkel, Evelyn ;
Lux, Michael P. ;
Schrauder, Michael ;
Koscheck, Thomas ;
Bautz, Werner ;
Schulz-Wendtland, Ruediger ;
Beckmann, Matthias W. ;
Bani, Mayada R. .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) :398-404
[9]   Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography [J].
Fornvik, Daniel ;
Zackrisson, Sophia ;
Ljungberg, Otto ;
Svahn, Tony ;
Timberg, Pontus ;
Tingberg, Anders ;
Andersson, Ingvar .
ACTA RADIOLOGICA, 2010, 51 (03) :240-247
[10]   Effect of Mammographic Screening Modality on Breast Density Assessment: Digital Mammography versus Digital Breast Tomosynthesis [J].
Gastounioti, Aimilia ;
McCarthy, Anne Marie ;
Pantalone, Lauren ;
Synnestvedt, Marie ;
Kontos, Despina ;
Conant, Emily F. .