Seismic behavior of composite shear walls incorporating concrete-filled steel and FRP tubes as boundary elements

被引:51
作者
Ren, Fengming [1 ]
Chen, Jinwen [1 ]
Chen, Guangming [2 ]
Guo, Yaxin [1 ]
Jiang, Tao [3 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Guangdong, Peoples R China
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou, Guangdong, Peoples R China
[3] Zhejiang Univ, Space Struct Res Ctr, Dept Civil Engn, Hangzhou, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Composite shear wall; Seismic behavior; Ductility; FRP-confined concrete cores; Concrete-filled steel tube (CFST); CFRP tube; SKIN TUBULAR COLUMNS; STRESS-STRAIN MODELS; AXIAL-COMPRESSION; CONFINED CONCRETE; FLEXURAL BEHAVIOR; STUB COLUMNS; PERFORMANCE; MEMBERS; BEAMS;
D O I
10.1016/j.engstruct.2018.04.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new form of a composite shear wall consisting of a reinforced concrete (RC) wall web and two boundary columns, in the form of square concrete-filled steel tubes (CFST) incorporating a carbon fiber reinforced polymer (CFRP)-confined concrete core, is proposed in this study. To evaluate its seismic performance, the proposed shear wall was tested under constant axial compression force and lateral cyclic loading. Three additional shear walls with different boundary column configurations were also tested: (i) an ordinary shear wall, (ii) a shear wall with CFST boundary columns, and (iii) a shear wall with double-skin CFST boundary columns. The failure mode, load-bearing capacity, ductility, energy dissipation capacity, stiffness degradation, strength degradation, and deformation mode of the four shear walls were thoroughly examined and compared. The results show that the deformation of the proposed shear wall was dominated by bending and that the distribution of axial strain generally satisfied the plane section assumption. The results also show that the seismic performance of the proposed shear wall was superior to that of the ordinary shear wall and the shear wall with CFST boundary columns. The proposed shear wall had the similar load-bearing capacity as the shear wall with double-skin CFST columns, but it had better ductility and larger dissipation capacity. This pilot study demonstrates that the composite shear wall has good potential for improving the performance of buildings constructed in seismic regions.
引用
收藏
页码:405 / 419
页数:15
相关论文
共 60 条
[1]   Behavior of FRP-HSC-Steel Double-Skin Tubular Columns under Cyclic Axial Compression [J].
Albitar, Mohammad ;
Ozbakkaloglu, Togay ;
Fanggi, Butje Alfonsius Louk .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (02)
[2]  
[Anonymous], 1997, UN BUILD COD
[3]  
[Anonymous], 2008, ACI318M08
[4]   Seismic behavior of code designed steel plate shear walls [J].
Berman, Jeffrey W. .
ENGINEERING STRUCTURES, 2011, 33 (01) :230-244
[5]  
Cao Wan-lin, 2008, Journal of Beijing University of Technology, V34, P1291
[6]   Research on seismic performance of shear walls with concrete filled steel tube columns and concealed steel trusses [J].
Cao Wanlin ;
Zhang Jianwei ;
Dong Hongying ;
Wang Min .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2011, 10 (04) :535-546
[7]  
China Ministry of Construction, 2012, 289002012 GBT CHIN M
[8]  
China Ministry of Construction, 2015, JGJT101 CHIN MIN CON
[9]  
China Ministry of Construction, 2010, 500112010 GB CHIN MI
[10]  
China Ministry of Construction, 2010, 501072010 GBT CHIN M