Comparison of Cone-Beam Imaging with Orthopantomography and Computerized Tomography for Assessment in Presurgical Implant Dentistry

被引:0
|
作者
Dreiseidler, Timo [1 ]
Mischkowski, Robert A. [1 ]
Neugebauer, Jorg [1 ]
Ritter, Lutz [1 ]
Zoeller, Joachim E. [1 ]
机构
[1] Univ Cologne, Dept Craniomaxillofacial & Plast Surg, D-50924 Cologne, Germany
关键词
computerized tomography; cone-beam imaging; dental implants; digital volume tomography; panoramic tomography; three-dimensional imaging; MAXILLOFACIAL-RADIOLOGY; CT; RADIOGRAPHY; DOSIMETRY; ACCURACY; DEVICES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To establish a basis for weighing the potential diagnostic and therapeutic benefits of three-dimensional cone-beam (CB) data sets in contrast to digital orthopantomography (OPG) and computerized tomography (CT) in implant dentistry. Materials and Methods: Twenty-seven patients requiring implant surgery received a single presurgical CB scan. A follow-up digital OPG was taken within a maximal postsurgical period of 2 weeks. For comparison purposes, a control group of 29 patients receiving CT as well as CB diagnosis was analyzed. Image quality of the different modalities was ranked retrospectively by five experienced examiners (from excellent to insufficient) for up to 10 defined criteria, including general image quality and several specific structures. The results were analyzed statistically, and interobserver agreement was calculated using intraclass correlation coefficients (ICCs). Results: The median rating for all investigated criteria was good for CB imaging and between good and insufficient for OPG in the dental implant group. Except for general image quality, statistical analysis showed that CB imaging was significantly superior to OPG imaging for all investigated anatomic structures. With a few exceptions, all investigated anatomic structures in CT and CB imaging were rated excellent in the control group. No significant difference between CT and CB imaging was detected in the control group for all investigated criteria. With a few exceptions, ICCs were higher for CB images than for OPG. In the control group, ICCs for CT and CB images were similar, with a few exceptions. Conclusion: The results of the present study confirm superior radiographic visualization for all important high-contrast structures in presurgical implant dentistry assessment for CB imaging in contrast to OPG and a CT-like degree of information for high-contrast structures in CB data sets. Clinically, however, the elevated radiation dosages transmitted by CB imaging must be taken into account. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:216-225
引用
收藏
页码:216 / 225
页数:10
相关论文
共 50 条
  • [1] Effects of tube current on cone-beam computerized tomography image quality for presurgical implant planning in vitro
    Sur, Jaideep
    Seki, Kenji
    Koizumi, Hiroshi
    Nakajima, Koh
    Okano, Tomohiro
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (03): : E29 - E33
  • [2] Digital implant impressions by cone-beam computerized tomography: a pilot study
    Corominas-Delgado, Cristina
    Espona, Jose
    Lorente-Gascon, Marian
    Real-Voltas, Francisco
    Roig, Miguel
    Costa-Palau, Santiago
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (11) : 1407 - 1413
  • [3] Detection of vertical root fracture using cone-beam computerized tomography: an in vitro assessment
    Kamburoglu, Kivanc
    Murat, Sema
    Yuksel, Selcen Pehlivan
    Cebeci, Ali Riza Ilker
    Horasan, Sinan
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (02): : E74 - E81
  • [5] Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning
    Poeschl, Paul W.
    Schmidt, Nina
    Guevara-Rojas, Godoberto
    Seemann, Rudolf
    Ewers, Rolf
    Zipko, Harald T.
    Schicho, Kurt
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 317 - 324
  • [6] Presurgical Planning in Implant Restorations: Correct Interpretation of Cone-Beam Computed Tomography for Improved Imaging
    Kourtis, S.
    Skondra, E.
    Roussou, I.
    Skondras, E. V.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (05) : 321 - 332
  • [7] A comparison of multislice computerized tomography, cone-beam computerized tomography, and single photon emission computerized tomography for the assessment of bone invasion by oral malignancies
    Dreiseidler, Timo
    Alarabi, Nuri
    Ritter, Lutz
    Rothamel, Daniel
    Scheer, Martin
    Zoeller, Joachim E.
    Mischkowski, Robert A.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (03): : 367 - 374
  • [8] Optimising the parameters of cochlear implant imaging with cone-beam computed tomography
    Soederqvist, Samuel
    Sivonen, Ville
    Aarnisalo, Antti
    Karppi, Harri
    Sinkkonen, Saku T.
    Koivisto, Juha
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) : 462 - 470
  • [9] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [10] Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers
    Hu, Kyung-Seok
    Choi, Da-Yae
    Lee, Won-Jae
    Kim, Hee-Jin
    Jung, Ui-Won
    Kim, Sungtae
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2012, 42 (02) : 39 - 44