Phantom size in brachytherapy source dosimetric studies

被引:127
作者
Pérez-Calatayud, J
Granero, D
Ballester, F
机构
[1] Univ Valencia, Dept Atom Mol & Nucl Phys, CSIC, E-46100 Burjassot, Spain
[2] Univ Valencia, IFIC, CSIC, E-46100 Burjassot, Spain
关键词
D O I
10.1118/1.1759826
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom size on brachytherapy for radionuclide Cs-137, Ir-192, I-125 and Pd-103, mainly used for clinical purposes. Using the GEANT4 Monte Carlo code, we can ascertain effects on derived dosimetry parameters and functions to establish a distance dependent difference due to the absence of full scatter conditions. We have found that for Cs-137 and Ir-192, a spherical phantom with a 40 cm radius is the equivalent of an unbounded phantom up to a distance of 20 cm from the source, as this size ensures full scatter conditions at this distance. For I-125 and Pd-103, the required radius for the spherical phantom in order to ensure full scatter conditions at 10 cm from the source is R = 15 cm. A simple expression based on fits of the dose distributions for various phantom sizes has been developed for Cs-137 and Ir-192 in order to compare the dose rate distributions published for different phantom sizes. Using these relations it is possible to obtain radial dose functions for unbounded medium from bounded phantom ones. (C) 2004 American Association Qf Physicists in Medicine.
引用
收藏
页码:2075 / 2081
页数:7
相关论文
共 30 条
[11]   Experimental determination of the TG-43 dosimetric characteristics of EchoSeed™ model 6733 125I brachytherapy source [J].
Meigooni, AS ;
Dini, SA ;
Sowards, K ;
Hayes, JL ;
Al-Otoom, A .
MEDICAL PHYSICS, 2002, 29 (06) :939-942
[12]   Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ 125I brachytherapy source [J].
Meigooni, AS ;
Hayes, JL ;
Zhang, HL ;
Sowards, K .
MEDICAL PHYSICS, 2002, 29 (09) :2152-2158
[13]  
Nath R, 1999, Cardiovasc Radiat Med, V1, P72, DOI 10.1016/S1522-1865(98)00007-9
[14]  
Nath R, 2002, MED PHYS, V29, P1349
[15]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[16]   Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source:: Evaluation of applicator attenuation and superposition approximation effects [J].
Pérez-Calatayud, J ;
Granero, D ;
Ballester, F ;
Puchades, V ;
Casal, E .
MEDICAL PHYSICS, 2004, 31 (03) :493-499
[17]   Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources [J].
Pérez-Calatayud, J ;
Ballester, F ;
Serrano-Andrés, MA ;
Lluch, JL ;
Puchades, V ;
Limami, Y ;
Casal, E .
MEDICAL PHYSICS, 2002, 29 (04) :538-543
[18]   Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type 137Cs sources [J].
Pérez-Calatayud, J ;
Ballester, F ;
Lluch, JL ;
Serrano-Andrés, MA ;
Casal, E ;
Puchades, V ;
Limami, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :2029-2040
[19]   A Monte Carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source [J].
Pérez-Calatayud, J ;
Lliso, F ;
Ballester, F ;
Serrano, MA ;
Lluch, JL ;
Limami, Y ;
Puchades, V ;
Casal, E .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :N169-N174
[20]   Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].
Rivard, MJ ;
Coursey, BM ;
DeWerd, LA ;
Hanson, WF ;
Huq, MS ;
Ibbott, GS ;
Mitch, MG ;
Nath, R ;
Williamson, JF .
MEDICAL PHYSICS, 2004, 31 (03) :633-674