On the Impact of Physiological Noise in Spinal Cord Functional MRI

被引:21
作者
Fratini, Michela [1 ,2 ,3 ]
Moraschi, Marta [1 ,2 ,4 ]
Maraviglia, Bruno [1 ,2 ,4 ]
Giove, Federico [1 ,2 ,3 ]
机构
[1] Museo Stor Fis, MARBILab, Rome, Italy
[2] Ctr Studi & Ric Enrico Fermi, Rome, Italy
[3] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[4] Fdn Santa Lucia, Rome, Italy
关键词
fMRI; physiological noise; spinal cord; BRAIN-STEM; NOCICEPTIVE RESPONSES; 7; T; FMRI; BOLD; CONTRAST; REDUCTION; ECHO; EPI; FLUCTUATIONS;
D O I
10.1002/jmri.24467
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional magnetic resonance imaging (fMRI) techniques are widely exploited for the study of brain activation. In recent years, similar approaches have been attempted for the study of spinal cord function; however, obtaining good functional images of spinal cord still represents a technical and scientific challenge. Some of the main limiting factors can be classified under the broad category of "physiological noise," and are related to 1) the cerebrospinal fluid (CSF) flux in the subarachnoid space surrounding the spinal cord; 2) the cord motion itself; and 3) the small area of the cord, which makes it critical to have a high image resolution. In addition, the different magnetic susceptibility properties of tissues surrounding the spinal cord reduce the local homogeneity of the static magnetic field, causing image distortion, reduction of the effective resolution, and signal loss, all effects that are modulated by motion. For these reasons, a number of methods have been developed for the purpose of denoising spinal cord fMRI time series. In this work, after a short introduction on the relevant features of the spinal cord anatomy, we review the main sources of physiological noise in spinal cord fMRI and discuss the main approaches useful for its mitigation.
引用
收藏
页码:770 / 777
页数:8
相关论文
共 75 条
[1]  
Anthea M, 1993, BIOL HLTH
[2]  
Backes WH, 2001, AM J NEURORADIOL, V22, P1854
[3]   A component based noise correction method (CompCor) for BOLD and perfusion based fMRI [J].
Behzadi, Yashar ;
Restom, Khaled ;
Liau, Joy ;
Liu, Thomas T. .
NEUROIMAGE, 2007, 37 (01) :90-101
[4]   fMRI of the brainstem using dual-echo EPI [J].
Beissner, Florian ;
Deichmann, Ralf ;
Baudrexel, Simon .
NEUROIMAGE, 2011, 55 (04) :1593-1599
[5]   Dual-echo EPI for non-equilibrium fMRI - Implications of different echo combinations and masking procedures [J].
Beissner, Florian ;
Baudrexel, Simon ;
Volz, Steffen ;
Deichmann, Ralf .
NEUROIMAGE, 2010, 52 (02) :524-531
[6]   Making the most of fMRI at 7 T by suppressing spontaneous signal fluctuations [J].
Bianciardi, Marta ;
van Gelderen, Peter ;
Duyn, Jeff H. ;
Fukunaga, Masaki ;
de Zwart, Jacco A. .
NEUROIMAGE, 2009, 44 (02) :448-454
[7]   Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI [J].
Birn, RM ;
Diamond, JB ;
Smith, MA ;
Bandettini, PA .
NEUROIMAGE, 2006, 31 (04) :1536-1548
[8]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[9]   Spinal cord functional MRI at 3 T: Gradient echo echo-planar imaging versus turbo spin echo [J].
Bouwman, C. J. C. ;
Wilmink, J. T. ;
Mess, W. H. ;
Backes, W. H. .
NEUROIMAGE, 2008, 43 (02) :288-296
[10]   Removing motion and physiological artifacts from intrinsic BOLD fluctuations using short echo data [J].
Bright, Molly G. ;
Murphy, Kevin .
NEUROIMAGE, 2013, 64 :526-537